Fernando Álvarez

Prof. Fernando Álvarez

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 March 2015 in Sensors
Verified
Journal Article
Open access
PDF file
FÁFernando Álvarez
Fernando Álvarez
FGFernando Garnacho
Fernando Garnacho
JOJavier Ortego
Javier Ortego
MSMiguel Ángel Sánchez-Urán
Miguel Ángel Sánchez-Urán
Partial discharge (PD) measurements provide valuable information for assessing the condition of high voltage (HV) insulation systems, contributing to their quality assurance. Different PD measuring techniques have been developed in the last years specially designed to perform on-line measurements. Non-conventional PD methods operating in high frequency bands are usually used when this type of tests are carried out. In PD measurements the signal acquisition, the subsequent signal processing and the capability to obtain an accurate diagnosis are conditioned by the selection of a suitable detection technique and by the implementation of effective signal processing tools. This paper proposes an optimized electromagnetic detection method based on the combined use of wideband PD sensors for measurements performed in the HF and UHF frequency ranges, together with the implementation of powerful processing tools. The effectiveness of the measuring techniques proposed is demonstrated through an example, where several PD sources are measured simultaneously in a HV installation consisting of a cable system connected by a plug-in terminal to a gas insulated substation (GIS) compartment.

6 March 2019 in IEEE Transactions on Power Delivery
Verified
Journal Article
Open access
MSMarina Adel Shokry
Marina Adel Shokry
AKAbderrahim Khamlichi
Abderrahim Khamlichi
FGFernando Garnacho
Fernando Garnacho
JMJulio Martinez Malo
Julio Martinez Malo
FÁFernando Álvarez
Fernando Álvarez
Nowadays many researchers are focusing on on-line condition monitoring of high-voltage (HV) insulated cable systems to prevent failures. With the aim of reducing the voltage induced in the cable sheaths, cross-bonding (CB) grounding cable systems are used in long distance power transmission land lines. This paper proposes a new criterion for the detection and localization of defects that might occur in the cables sheath when a CB configuration is adopted. The criterion proposed can be applied at different levels of load current. For the application of the criterion, the cable system under evaluation is modeled using the ATP software. Various practical cases were studied showing the effectiveness of the criterion for the detection and localization of different types of defects in simulated cable systems. Furthermore, in order to validate the criteria adopted for the defect detection, based on the ATP model, a real defected case was evaluated. The results obtained proved that this criterion is suitable for the detection and localization of defects in the cables sheath, when on-line measurements are performed in monitoring applications.

28 February 2018 in Sensors
Verified
Journal Article
Open access
PDF file
FÁFernando Álvarez
Fernando Álvarez
Ricardo AlbarracínRicardo Albarracín
Ricardo Albarracín
FVFernando Garnacho Vecino
Fernando Garnacho Vecino
RARicardo Granizo Arrabé
Ricardo Granizo Arrabé
Partial discharges (PD) measurement provides valuable information for the condition assessment of the insulation status of high-voltage (HV) electrical installations. During the last three decades, several PD sensors and measuring techniques have been developed to perform accurate diagnostics when PD measurements are carried out on-site and on-line. For utilities, the most attractive characteristics of on-line measurements are that once the sensors are installed in the grid, the electrical service is uninterrupted and that electrical systems are tested in real operating conditions. In medium-voltage (MV) and HV installations, one of the critical points where an insulation defect can occur is inside metal-clad switchgears (including the cable terminals connected to them). Thus, this kind of equipment is increasingly being monitored to carry out proper maintenance based on their condition. This paper presents a study concerning the application of different electromagnetic measuring techniques (compliant with IEC 62478 and IEC 60270 standards), together with the use of suitable sensors, which enable the evaluation of the insulation condition mainly in MV switchgears. The main scope is to give a general overview about appropriate types of electromagnetic measuring methods and sensors to be applied, while considering the level of detail and accuracy in the diagnosis and the particular fail-save requirements of the electrical installations where the switchgears are located.

9 January 2020 in Sensors
Verified
Journal Article
Open access
PDF file
Ricardo AlbarracínRicardo Albarracín
Ricardo Albarracín
FÁFernando Álvarez
Fernando Álvarez
Carlos Vera RomeroCarlos Vera Romero
Carlos Vera Romero
JRJohnatan M. Rodríguez-Serna
Johnatan M. Rodríguez-Serna
During the last two decades, on-line partial discharge (PD) measurements have been proven as a very efficient test to evaluate the insulation condition of high-voltage (HV) installations in service. Among the different PD-measuring techniques, the non-conventional electromagnetic methods are the most used due to their effectiveness and versatility. However, there are two main difficulties to overcome in on-line PD measurements when these methods are applied: the ambient electric noise and the simultaneous presence of various types of PD or pulse-shaped signals in the HV facility to be evaluated. A practical and effective method is presented to separate and identify PD sources acting simultaneously in HV systems under test. This method enables testers to carry out a first accurate diagnosis of the installation while performing the measurements in situ with non-invasive high-frequency current transformers (HFCT) used as sensors. The data acquisition in real-time reduces the time of postprocessing by an expert. This method was implemented in a Matlab application named PRPD-time tool, which consists of the analysis of the Phase-Resolved Partial Discharge (PRPD) pattern in combination with two types of interactive graphic representations. These graphical depictions are obtained including a feature parameter, effective time (teff), related to the duration of single measured pulses as a third axis incorporated in a classical PRPD representation, named the PRPD-teff pattern. The resulting interactive diagrams are complementary and allow the pulse source separation of pulses and clustering. The effectiveness of the proposed method and the developed Matlab application for separating PD sources is demonstrated with a practical laboratory experiment where various PD sources and pulse-type noise interferences were simultaneously measured.

13 October 2015 in Sensors
Verified
Journal Article
Open access
PDF file
JRJorge Alfredo Ardila Rey
Jorge Alfredo Ardila Rey
Ricardo AlbarracínRicardo Albarracín
Ricardo Albarracín
FÁFernando Álvarez
Fernando Álvarez
ABAldo Enrique Barrueto
Aldo Enrique Barrueto
Both in industrial as in controlled environments, such as high-voltage laboratories, pulses from multiple sources, including partial discharges (PD) and electrical noise can be superimposed. These circumstances can modify and alter the results of PD measurements and, what is more, they can lead to misinterpretation. The spectral power clustering technique (SPCT) allows separating PD sources and electrical noise through the two-dimensional representation (power ratio map or PR map) of the relative spectral power in two intervals, high and low frequency, calculated for each pulse captured with broadband sensors. This method allows to clearly distinguishing each of the effects of noise and PD, making it easy discrimination of all sources. In this paper, the separation ability of the SPCT clustering technique when using a Rogowski coil for PD measurements is evaluated. Different parameters were studied in order to establish which of them could help for improving the manual selection of the separation intervals, thus enabling a better separation of clusters. The signal processing can be performed during the measurements or in a further analysis.

13 May 2022 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
RARicardo Granizo Arrabé
Ricardo Granizo Arrabé
JGJose Manuel Guerrero
Jose Manuel Guerrero
FÁFernando Álvarez
Fernando Álvarez
Carlos A. PlateroCarlos A. Platero
Carlos A. Platero
Ground faults are the main cause of electrical failure in transmission and distribution systems. In ungrounded distribution networks, it is difficult to detect where a first ground fault has happened as only capacitive currents are available. Also, it is important to trip only the faulty line in order to ensure the system's reliability. Directional residual overcurrent relays are the standard solution for these systems, but their difficult commissioning and high costs make it not trivial. This paper introduces a new selective and directional protection method to determine the faulty line in ungrounded medium voltage networks with three or more feeders. The method evaluates the residual currents in the feeders coupled to the same busbars in combination with a reference current created by the sum of a combination of residual currents of all feeders. Both simulation and laboratory results validate this new method, which is easy to start up, as it does not need previous configurations for its implementation, and it presents an economical solution to this problem.