Chunfang Rao

Dr. Chunfang Rao


Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 March 2019 in Sensors
Verified
Journal Article
Open access
PDF file
CRChunfang Rao
Chunfang Rao
Lingze DuanLingze Duan
Lingze Duan
Lamb wave (LW) is well suited for structural health monitoring (SHM) in advanced composites. However, characteristic differences between the symmetric modes and the anti-symmetric modes often add complexity to SHM systems. The anisotropic nature of composite materials, on the other hand, necessitates direction-sensitive sensing. In this paper we report the experimental demonstration of bidirectional (0° and 90°), bimodal (S0 and A0) LW measurement within the frequency range of 20–140 kHz using a polarization-maintaining fiber Bragg grating (PM-FBG) sensor attached to a composite laminated plate. By selectively interrogating the fast and/or the slow axis of the PM-FBG, we show that not only can the sensor respond to LWs propagating along both directions, but the response can also be used to differentiate the two directions. Moreover, the fast axis of the sensor is able to respond to both the S0 and the A0 modes when the sensor is aligned with the wave propagation direction, whereas single S0 mode response can be achieved with the slow axis operating perpendicularly to the wave propagation direction. Such diverse responses indicate the potential of PM-FBGs as versatile multi-parameter SHM detectors, which can effectively address the challenges posed by material anisotropicity and LW mode diversity.

1 May 2013 in Optical Engineering
Verified
Journal Article
Closed access
PDF file
CRChunfang Rao
Chunfang Rao
HZHua Zhang
Hua Zhang
YFYan Feng
Yan Feng
LXLili Xiao
Lili Xiao
ZYZhiqing Ye
Zhiqing Ye
Metal coating can provide fiber Bragg grating (FBG) effective protection and improve the FBG sensor’s performance in harsh environments. However, the metalizing can impact the optical properties of the FBG. As a result, the sensor accuracy of FBG will lower. The reason for the effect is the stress produced in the metalizing. In this study, we coated the FBG by the electroless-electroplating method. The common changes of the FBG’s spectrum after the metalizing were apparent side-lobes and reduced peak loss, and the hysteresis error for temperature sensor was more than 3.5°C. To reduce the deformation of the FBG’s spectrum in the metalizing, we analyzed the origin of stress, calculated the FBG’s refractive index perturbation due to the thermal stress, and simulated the spectrums of FBG under different stress distributions. On the basis of this, we developed a stress control technology. After using the technology, the optical properties of the metal-coated fiber Bragg gratings have been retained, and their hysteresis errors for temperature sensors were less than 1.5°C. The results showed good repeatability. The study can be used for regulating metalizing processes, and for providing valuable information for metalizing other optical fiber devices.

23 August 2018 in Optical Engineering
Verified
Journal Article
Open access
YZYuan-Feng Zhu
Yuan-Feng Zhu
XLXin Liu
Xin Liu
CRChunfang Rao
Chunfang Rao
HZHua Zhong
Hua Zhong
HLHai-Mei Luo
Hai-Mei Luo
HWHua Wang
Hua Wang
The flagship monthly journal of SPIE, Optical Engineering (OE) publishes peer-reviewed papers reporting on research and development in all areas of optics, photonics, and imaging science and engineering.

7 November 2025 in Applied Optics
Verified
Journal Article
Closed access
YMYiming Ma
Yiming Ma
CRChunfang Rao
Chunfang Rao
This study aims to develop a three-dimensional fiber Bragg grating (FBG) accelerometer fabricated from non-metallic materials, thereby rendering it suitable for application in high-voltage or strong electromagnetic field environments. An integral inertial mass block, incorporating two types of flexible hinges fabricated from high-strength resin matrix composites, was designed. Theoretical analyses and optimization procedures were employed to identify the optimal geometric parameters. Finite-element method simulations and experimental evaluations indicate that the operational frequency range extends from 10 to 70 Hz. The sensitivities of the accelerometer along the x, y, and z axes were measured as 65.92, 122.53, and 61.45 pm/g, respectively. The sensor demonstrates excellent linearity and load capacity in its acceleration response.

29 July 2016 in Experimental Mechanics
Verified
Journal Article
Closed access
PDF file
CRChunfang Rao
Chunfang Rao
ZYZ. Ye
Z. Ye
HZH. Zhong
H. Zhong
YZY. Zhu
Y. Zhu