In this work, the mechanical behaviour of millimetre-scale, bulk single crystalline, nanoporous gold at room temperature is reported for the first time. Tension and compression tests were performed with a custom-designed test system that accommodates small-scale samples. The absence of grain boundaries in the specimens allowed measurement of the inherent strength of millimetre-scale nanoporous gold in tension. The elastic modulus and strength values in tension and compression were found to be significantly lower than values measured with nanoindentation-based techniques and previously reported in the literature, but close to those reported for millimetre-scale polycrystalline samples tested using traditional compression techniques. Fracture toughness was found to be very low, in agreement with the macroscopic brittleness of nanoporous gold, but this is due to the localization of deformation to a narrow zone of ligaments, which individually exhibit significant plasticity and necking.
5 April 2018 in IEEE Transactions on Electron Devices
The high electron emission resulting from low-work-function scandate-added dispenser cathodes has generated a great deal of interest and research since the late 1970s. Despite the reported high current density at low temperatures, scandate cathodes have not yet seen wide-scale industrial adoption due to poor emission uniformity, inadequate reproducibility, and short lifetimes. This lack of industrial adoption stemming from the above issues is likely due to insufficient fundamental understanding of the role that scandium plays in the emission process. Recent work by five research teams under the U.S. Defense Advanced Research Projects Agency Innovative Vacuum Electronics Science and Technology Program aims at advancing this fundamental understanding and the cathode manufacturing processing. Emission microscopy of model surfaces of adsorbed Ba-Sc-O on single crystal tungsten and detailed characterization techniques, such as Wulff shape analysis, are being used to understand the morphology, composition and phase of each of the species that comprise the cathode emitting surfaces. The structure of tungsten grains at the cathode surface of activated and unactivated scandate cathodes and the resulting emission performance are observed. 3-D printing is being investigated as an advanced manufacturing method to meet the demanding requirements of modern vacuum electron devices. Finally, density functional theory is being employed to study the work function of perovskite oxides as a novel class of alternative materials to tungsten dispenser cathodes.
The mechanical properties of bulk nanoporous gold (np–Au) with a relative density of 0.35 were investigated by compression testing of millimetre-scale specimens. Young’s modulus, Poisson’s ratio and yield strength values were determined from uniaxial, quasi-static experiments using a custom-built mechanical testing system. The cuboid-shaped specimens were fabricated following a specific, controlled process (including cutting and grinding) that guaranteed a precise and repeatable geometry. The np–Au structure was created from a silver–gold alloy by electrochemical dealloying in nitric acid. Mechanical properties obtained from compression testing are compared to values reported in the literature and to scaling relations. Values are found to agree with a recently proposed scaling relation for the yield strength of np–Au that incorporates a ligament size effect and a modified scaling exponent.
The structural evolution of nanoporous gold during thermal treatment was studied by annealing samples in vacuum and in flowing nitrogen. As expected, ligament thickness generally increased in both environments. However, ligaments annealed at high temperature in vacuum remained relatively narrow, undergoing much less coarsening than nitrogen-annealed samples, albeit with some ligament agglomeration. When annealed in flowing nitrogen, gold ligaments coarsened significantly at temperatures above 300 °C. This discrepancy is attributed to different surface diffusion rates of gold in the two annealing environments. The current results suggest that diffusion on the surfaces of nanoporous gold ligaments proceeds more quickly in nitrogen than in vacuum.
Although thermionic emission has been studied for more than 100 years, recent interest in novel electron devices for military and civilian use has led to a surge in demand for cathodes with enhanced emission properties (e.g., higher current density, more uniform emission, lower operating temperatures, or extended in-service longevity). Sc-containing “scandate” cathodes have been widely reported to exhibit superior emission properties compared to previous-generation thermionic cathodes, including oxide, B-, and M-type cathodes. Despite extensive study spanning several decades, the mechanism by which the addition of Sc enhances cathode emission remains ambiguous, and nonuniform emission, low reproducibility, and inconsistent longevity continue to prevent widespread commercial integration of scandate cathodes into electron devices. This first part of a two-part review explores approaches that have been used for fabricating Sc-containing thermionic cathodes and the microstructures and emitting properties that result.