Toshiaki Hattori

Dr. Toshiaki Hattori

Department of Electrical and Electronic Information Engineering, Toyohashi University of Technology, Toyohashi, Japan

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 October 2010 in Analytical Sciences
Verified
Journal Article
Open access
PDF file
THToshiaki Hattori
Toshiaki Hattori
YMYoshitomo Masaki
Yoshitomo Masaki
KAKazuya Atsumi
Kazuya Atsumi
RKRyo Kato
Ryo Kato
KSKazuaki Sawada
Kazuaki Sawada
Two-dimensional real-time observation of potassium ion distributions was achieved using an ion imaging device based on charge-coupled device (CCD) and metal-oxide semiconductor technologies, and an ion selective membrane. The CCD potassium ion image sensor was equipped with an array of 32 × 32 pixels (1024 pixels). It could record five frames per second with an area of 4.16 × 4.16 mm2. Potassium ion images were produced instantly. The leaching of potassium ion from a 3.3 M KCl Ag/AgCl reference electrode was dynamically monitored in aqueous solution. The potassium ion selective membrane on the semiconductor consisted of plasticized poly(vinyl chloride) (PVC) with bis(benzo-15-crown-5). The addition of a polyhedral oligomeric silsesquioxane to the plasticized PVC membrane greatly improved adhesion of the membrane onto Si3N4 of the semiconductor surface, and the potential response was stabilized. The potential response was linear from 10−2 to 10−5 M logarithmic concentration of potassium ion. The selectivity coefficients were KK+,Li+pot = 10−2.85, KK+,Na+pot = 10−2.30, KK+,Rb+pot =10−1.16, and KK+,Cs+pot = 10−2.05.

13 December 2011 in Electroanalysis
Verified
Journal Article
Closed access
PDF file
THToshiaki Hattori
Toshiaki Hattori
MYMasaki Yoshitomo
Masaki Yoshitomo
SMSatoshi Mori
Satoshi Mori
DMDaichi Miyamoto
Daichi Miyamoto
RKRyo Kato
Ryo Kato
KSKazuaki Sawada
Kazuaki Sawada

1 April 2019 in Sensors
Verified
Journal Article
Open access
PDF file
THToshiaki Hattori
Toshiaki Hattori
FDFumihiro Dasai
Fumihiro Dasai
HSHikaru Sato
Hikaru Sato
RKRyo Kato
Ryo Kato
KSKazuaki Sawada
Kazuaki Sawada
A semiconductor array pH image sensor consisting of four separated blocks was fabricated using charged coupled device (CCD) and complementary metal oxide semiconductor (CMOS) technologies. The sensing surface of one of the four blocks was Si3N4 and this block responded to H+. The surfaces of the other three blocks were respectively covered with cation sensitive membranes, which were separately printed with plasticized poly (vinyl chloride) solutions including Na+, K+, and Ca2+ ionophores by using an ink-jet printing method. In addition, each block of the image sensor with 128 × 128 pixels could have a calibration curve generated in each independent measurement condition. The present sensor could measure the concentration image of four kinds of ions (H+, K+, Na +, Ca2+) simultaneously at 8.3 frames per second (fps) in separated regions on a chip.

11 January 2013
Verified
Book Chapter
Closed access
PDF file
THToshiaki Hattori
Toshiaki Hattori
NANobuhiro Anraku
Nobuhiro Anraku
RKRyo Kato
Ryo Kato

1 January 2016 in BUNSEKI KAGAKU
Verified
Journal Article
Open access
PDF file
KHKenji Hirota
Kenji Hirota
RKRyo Kato
Ryo Kato
KSKazuaki Sawada
Kazuaki Sawada
THToshiaki Hattori
Toshiaki Hattori

14 March 2020 in Bulletin of the Chemical Society of Japan
Verified
Journal Article
Closed access
FNFumiya Nakamura
Fumiya Nakamura
TNTaisei Nakayama
Taisei Nakayama
IKItsuki Kageyama
Itsuki Kageyama
RKRyo Kato
Ryo Kato
MNMoeto Nagai
Moeto Nagai
THToshiaki Hattori
Toshiaki Hattori
Up to now several bio-imaging methods have taken a very good pictures and/or recordings. With the bio-imaging growing, a micro-stimulation method to limit in a fine region is required. A conventional chemical stimulation method is hard to response its requirement, however, an electrochemical device is potential to response the issue. This paper reports on the fabrication and the use of an electrochemical Ca2+-releasing device. The device consists of a three-layer electrode, including two transducers, a PVC membrane, PEDOT layer, and gold or carbon. The dynamic behavior of Ca2+ released from the device is evaluated by a two-dimensional 16K pixels array Ca2+ image sensor, and is simulated using a diffusion model of Ca2+. Both experimental and calculated time and distance dependent profiles are almost agreed when the PVC membrane is thin. As its biological application, a permeabilized Vorticella convallaria was set at a distance of ca. 0.1 mm from the Ca2+-releasing device. There was no response for some time just after the switching-on, and then it gradually contracted. The gradual contraction after the interval proved that the Ca2+-releasing device can be used a soft insertion based on the concentration diffusion.