Kazuaki Sawada

Prof. Kazuaki Sawada

Department of and Electronic Information Engineering Toyohashi, University of Technology, oyohashi, Japan

Research Focus & Metrics

Academic Career Length

38Years (1989-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 June 2012 in Sensors
Verified
Journal Article
Open access
PDF file
MFMasato Futagawa
Masato Futagawa
TITaichi Iwasaki
Taichi Iwasaki
HMHiroaki Murata
Hiroaki Murata
MIMakoto Ishida
Makoto Ishida
KSKazuaki Sawada
Kazuaki Sawada
Making several simultaneous measurements with different kinds of sensors at the same location in a solution is difficult because of crosstalk between the sensors. In addition, because the conditions at different locations in plant beds differ, in situ measurements in agriculture need to be done in small localized areas. We have fabricated a multimodal sensor on a small Si chip in which a pH sensor was integrated with electrical conductivity (EC) and temperature sensors. An ISFET with a Si3N4 membrane was used for the pH sensor. For the EC sensor, the electrical conductivity between platinum electrodes was measured, and the temperature sensor was a p-n junction diode. These are some of the most important measurements required for controlling the conditions in plant beds. The multimodal sensor can be inserted into a plant bed for in situ monitoring. To confirm the absence of crosstalk between the sensors, we made simultaneous measurements of pH, EC, and temperature of a pH buffer solution in a plant bed. When the solution was diluted with hot or cold water, the real time measurements showed changes to the EC and temperature, but no change in pH. We also demonstrated that our sensor was capable of simultaneous in situ measurements in rock wool without being affected by crosstalk.

24 January 2019 in IEEE Transactions on Biomedical Circuits and Systems
Verified
Journal Article
Closed access
YLYou-Na Lee
You-Na Lee
TATakeshi Araki
Takeshi Araki
YKYasuyuki Kimura
Yasuyuki Kimura
FDFumihiro Dasai
Fumihiro Dasai
TITatsuya Iwata
Tatsuya Iwata
KSKazuaki Sawada
Kazuaki Sawada
Various biosensing platforms for real-time monitoring and mapping of chemical signals in neural networks have been developed based on CMOS process technology. Despite their achievements, however, there remains a demand for an advanced method that can offer detailed insights into cellular functions with higher spatiotemporal resolution. Here, we present a pH image sensor that employs a high-density array of 256 × 256 pixels and readout circuitry designed for fast operation. The sensor's characteristics, such as the pH sensitivity of 55.1 mV/pH and higher frame speed of 1933 fps, are experimentally demonstrated and compared to those of state-of-the-art pH image sensors. Among them, our sensor presents the smallest pitch of 2 μm with a significantly high operation speed. This sensor can successfully detect a pH change, but also transform the measured data to a two-dimensional (2D) image series in real-time. The practical spatial resolution of images is investigated by an evaluation method that we firstly propose in this work. By this method, we confirm that our sensor can discriminate objects distanced over 4 μm apart which is twice bigger than the pixel pitch. In order to analyze the degraded resolution and image blur, a capacitive coupling effect at an ion-sensitive membrane is suggested as the main factor and demonstrated by simulation.

20 September 2017 in Sensors
Verified
Journal Article
Open access
PDF file
TITatsuya Iwata
Tatsuya Iwata
KMKyosuke Matsuda
Kyosuke Matsuda
KTKazuhiro Takahashi
Kazuhiro Takahashi
KSKazuaki Sawada
Kazuaki Sawada
Demand for the detection of carbon dioxide (CO 2 ) is increasing in various fields, including air-quality monitoring, healthcare, and agriculture. On the other hand, smart gas sensors, in which micromachined gas sensors are integrated with driving circuits, are desirable toward the development of the society of the internet of things. In this study, micromachined hotplate-based CO 2 sensors were fabricated and their characteristics were investigated. The sensors have La 2 O 3 /SnO 2 stacked layers as a sensing material and Pt interdigitated electrodes. A CO 2 response of 2.9 for a CO 2 concentration of 1000 ppm was obtained at 350 °C with low power consumption (approximately 17 mW). A relatively large response was obtained compared with previous studies even though a compact sputtered-SnO 2 film was used. This high response was speculated to be due to a significant contribution of the resistance component near the electrode. Furthermore, CO 2 sensing was successfully performed in the CO 2 range of 200–4000 ppm with at least 200-ppm resolution.

5 February 2020 in Nature Communications
Verified
Journal Article
Open access
PDF file
HHHiroshi Horiuchi
Hiroshi Horiuchi
MAMasakazu Agetsuma
Masakazu Agetsuma
JIJunko Ishida
Junko Ishida
YNYusuke Nakamura
Yusuke Nakamura
DCDennis Lawrence Cheung
Dennis Lawrence Cheung
Junichi NabekuraJunichi Nabekura
Junichi Nabekura
Recent studies have shown that protons can function as neurotransmitters in cultured neurons. To further investigate regional and neural activity-dependent proton dynamics in the brain, the development of a device with both wide-area detectability and high spatial-ltemporal resolution is necessary. Therefore, we develop an image sensor with a high spatial-temporal resolution specifically designed for measuring protons in vivo. Here, we demonstrate that spatially deferent neural stimulation by visual stimulation induced distinct patterns of proton changes in the visual cortex. This result indicates that our biosensor can detect micrometer and millisecond scale changes of protons across a wide area. Our study demonstrates that a CMOS-based proton image sensor with high spatial and temporal precision can be used to detect pH changes associated with biological events. We believe that our sensor may have broad applicability in future biological studies.

30 April 2002 in Japanese Journal of Applied Physics
Verified
Journal Article
Closed access
MAMasahiro Akiyama
Masahiro Akiyama
MHMasaki Hanada
Masaki Hanada
HTHidekuni Takao
Hidekuni Takao
KSKazuaki Sawada
Kazuaki Sawada
MIMakoto Ishida
Makoto Ishida

13 December 2011 in Electroanalysis
Verified
Journal Article
Closed access
PDF file
THToshiaki Hattori
Toshiaki Hattori
MYMasaki Yoshitomo
Masaki Yoshitomo
SMSatoshi Mori
Satoshi Mori
DMDaichi Miyamoto
Daichi Miyamoto
RKRyo Kato
Ryo Kato
KSKazuaki Sawada
Kazuaki Sawada