Making several simultaneous measurements with different kinds of sensors at the same location in a solution is difficult because of crosstalk between the sensors. In addition, because the conditions at different locations in plant beds differ, in situ measurements in agriculture need to be done in small localized areas. We have fabricated a multimodal sensor on a small Si chip in which a pH sensor was integrated with electrical conductivity (EC) and temperature sensors. An ISFET with a Si3N4 membrane was used for the pH sensor. For the EC sensor, the electrical conductivity between platinum electrodes was measured, and the temperature sensor was a p-n junction diode. These are some of the most important measurements required for controlling the conditions in plant beds. The multimodal sensor can be inserted into a plant bed for in situ monitoring. To confirm the absence of crosstalk between the sensors, we made simultaneous measurements of pH, EC, and temperature of a pH buffer solution in a plant bed. When the solution was diluted with hot or cold water, the real time measurements showed changes to the EC and temperature, but no change in pH. We also demonstrated that our sensor was capable of simultaneous in situ measurements in rock wool without being affected by crosstalk.
24 January 2019 in IEEE Transactions on Biomedical Circuits and Systems
Various biosensing platforms for real-time monitoring and mapping of chemical signals in neural networks have been developed based on CMOS process technology. Despite their achievements, however, there remains a demand for an advanced method that can offer detailed insights into cellular functions with higher spatiotemporal resolution. Here, we present a pH image sensor that employs a high-density array of 256 × 256 pixels and readout circuitry designed for fast operation. The sensor's characteristics, such as the pH sensitivity of 55.1 mV/pH and higher frame speed of 1933 fps, are experimentally demonstrated and compared to those of state-of-the-art pH image sensors. Among them, our sensor presents the smallest pitch of 2 μm with a significantly high operation speed. This sensor can successfully detect a pH change, but also transform the measured data to a two-dimensional (2D) image series in real-time. The practical spatial resolution of images is investigated by an evaluation method that we firstly propose in this work. By this method, we confirm that our sensor can discriminate objects distanced over 4 μm apart which is twice bigger than the pixel pitch. In order to analyze the degraded resolution and image blur, a capacitive coupling effect at an ion-sensitive membrane is suggested as the main factor and demonstrated by simulation.
Demand for the detection of carbon dioxide (CO ) is increasing in various fields, including air-quality monitoring, healthcare, and agriculture. On the other hand, smart gas sensors, in which micromachined gas sensors are integrated with driving circuits, are desirable toward the development of the society of the internet of things. In this study, micromachined hotplate-based CO sensors were fabricated and their characteristics were investigated. The sensors have La O /SnO stacked layers as a sensing material and Pt interdigitated electrodes. A CO response of 2.9 for a CO concentration of 1000 ppm was obtained at 350 °C with low power consumption (approximately 17 mW). A relatively large response was obtained compared with previous studies even though a compact sputtered-SnO film was used. This high response was speculated to be due to a significant contribution of the resistance component near the electrode. Furthermore, CO sensing was successfully performed in the CO range of 200–4000 ppm with at least 200-ppm resolution.
Recent studies have shown that protons can function as neurotransmitters in cultured neurons. To further investigate regional and neural activity-dependent proton dynamics in the brain, the development of a device with both wide-area detectability and high spatial-ltemporal resolution is necessary. Therefore, we develop an image sensor with a high spatial-temporal resolution specifically designed for measuring protons in vivo. Here, we demonstrate that spatially deferent neural stimulation by visual stimulation induced distinct patterns of proton changes in the visual cortex. This result indicates that our biosensor can detect micrometer and millisecond scale changes of protons across a wide area. Our study demonstrates that a CMOS-based proton image sensor with high spatial and temporal precision can be used to detect pH changes associated with biological events. We believe that our sensor may have broad applicability in future biological studies.
30 April 2002 in Japanese Journal of Applied Physics