Johann Cassar

Mr. Johann Cassar

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 March 2019 in Electronics
Verified
Journal Article
Open access
PDF file
JCJohann Cassar
Johann Cassar
ASAndrew Sammut
Andrew Sammut
Nicholas SammutNicholas Sammut
Nicholas Sammut
Marco CalviMarco Calvi
Marco Calvi
SDSasa Dimitrijevic
Sasa Dimitrijevic
RPRadivoje S. Popovic
Radivoje S. Popovic
A novel three-axis teslameter and other similar machines have been designed and developed for SwissFEL at the Paul Scherrer Institute (PSI). The developed instrument will be used for high fidelity characterisation and optimisation of the undulators for the ATHOS soft X-ray beamline. The teslameter incorporates analogue signal conditioning for the three-axes interface to a SENIS Hall probe, an interface to a Heidenhain linear absolute encoder and an on-board high-resolution 24-bit analogue-to-digital conversion. This is in contrast to the old instrumentation setup used, which only comprises the analogue circuitry with digitization being done externally to the instrument. The new instrument fits in a volumetric space of 150 mm × 50 mm × 45 mm, being very compact in size and also compatible with the in-vacuum undulators. This paper describes the design and the development of the different components of the teslameter. Performance results are presented that demonstrate offset fluctuation and drift (0.1–10 Hz) with a standard deviation of 0.78 µT and a broadband noise (10–500 Hz) of 2.05 µT with an acquisition frequency of 2 kHz.

13 January 2020 in Electronics
Verified
Journal Article
Open access
PDF file
JCJohann Cassar
Johann Cassar
ASAndrew Sammut
Andrew Sammut
Nicholas SammutNicholas Sammut
Nicholas Sammut
Marco CalviMarco Calvi
Marco Calvi
ZMZarko Mitrovic
Zarko Mitrovic
RPRadivoje S. Popovic
Radivoje S. Popovic
A new reduced form-factor three axes digital teslameter, based on the spinning current technique, has been developed. This instrument will be used to characterize the SwissFEL insertion devices at the Paul Scherrer Institute (PSI) for the ATHOS soft X-ray beamline. A detailed and standardized calibration procedure is critical to optimize the performance of this precision instrument. This paper presents the measurement techniques used for the corrective improvements implemented through non-linearity, temperature offset, temperature sensitivity compensation of the Hall probe and electronics temperature compensation. A detailed quantitative analysis of the reduction in errors on the application of each step of the calibration is presented. The percentage peak error reduction attained through calibration of the instrument for reference fields in the range of ±2 T is registered to drop from 1.94% down to 0.02%.

28 October 2019 in Electronics
Verified
Journal Article
Open access
PDF file
JCJohann Cassar
Johann Cassar
ASAndrew Sammut
Andrew Sammut
Nicholas SammutNicholas Sammut
Nicholas Sammut
Marco CalviMarco Calvi
Marco Calvi
SSSasa Spasic
Sasa Spasic
DRDragana Popovic Renella
Dragana Popovic Renella
In the framework of the SwissFEL project at the Paul Scherrer Institute (PSI), a Hall probe bench is being developed for the high-precision magnetic characterization of the insertion devices for the ATHOS soft X-ray beamline. For this purpose, a novel three-axis teslameter has been developed, which will be placed between the undulator and its outer shell in a very limited volumetric space of 150 × 50 × 45 mm. Together with a SENIS® 3-axis Hall probe at the center of the cross sectional area of the undulator, the setup will traverse along the undulator length on a specifically designed rig with minimal vibrations. This teslameter has all the analog signal conditioning circuitry for the Hall probe and also has on board 24-bit digitization. The instrument also handles an interface to a linear absolute encoder. The old instrumentation used only had analog signal conditioning circuitry whilst digitization was done off board. The new instrument also provides a very accurate magnetic field map in the µT range with simultaneous readings from the position encoder at an accuracy of ±3 µm. In this paper, a series of tests are described, which were performed at PSI in order to establish the measuring precision and repeatability of the instrument.