Andrew Sammut

Dr. Andrew Sammut

orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 October 2024 in Physical Review Accelerators and Beams
Verified
Journal Article
Open access
Marco CalviMarco Calvi
Marco Calvi
AAAlexandre Arsenault
Alexandre Arsenault
XLXiaoyang Liang
Xiaoyang Liang
TSThomas Schmidt
Thomas Schmidt
ADAnthony R. Dennis
Anthony R. Dennis
SHSebastian Hellmann
Sebastian Hellmann
The magnetic field optimization of RE-Ba-Cu-O (REBCO, RE = rare earth) bulk superconducting undulators is a fundamental step toward their implementation in an accelerator driven photon source, like a synchrotron or a free electron laser. In this article, we propose a sorting algorithm to reduce the undulator’s phase error based on the reconstruction of the trapped current inside the bulks of a staggered array undulator. The results obtained with a YBCO short prototype field-cooled down to 10 K in a 10 T magnetic field are reported. Finally, its performance is critically discussed in light of 2D magnetic field maps of its individual components, obtained at LN 2 after the magnetization tests. Published by the American Physical Society 2024

1 October 2016
Verified
Conference Paper
Closed access
KHKenneth Hili
Kenneth Hili
ASAndrew Sammut
Andrew Sammut
Most modern outdoor tracking systems utilize GPS technology. However, typical pedestrian environments tend to distort and block satellite signals, thereby making GPS communication systems unreliable. This is particularly true for indoor environments. An alternative pedestrian dead reckoning system based solely on inertial sensors is presented. Noisy acceleration signals result in a heavy velocity drift. This study proposes static-period and dynamic-period compensation methods that would allow for accurate 2-D positioning to be estimated. Data fitting techniques are used to reset velocity drift error after every step, thereby preventing accumulation of errors, as well as to compensate for the errors incurred during the step itself. Results show that the combined system is able to track rectilinear motion under normal walking conditions with an average accuracy of 1.4%, while various lengths of non-linear 2-D paths travelled by different users with varying gaits, paces and directions were successfully tracked with a maximum error of 5%.

26 March 2019 in Electronics
Verified
Journal Article
Open access
PDF file
JCJohann Cassar
Johann Cassar
ASAndrew Sammut
Andrew Sammut
Nicholas SammutNicholas Sammut
Nicholas Sammut
Marco CalviMarco Calvi
Marco Calvi
SDSasa Dimitrijevic
Sasa Dimitrijevic
RPRadivoje S. Popovic
Radivoje S. Popovic
A novel three-axis teslameter and other similar machines have been designed and developed for SwissFEL at the Paul Scherrer Institute (PSI). The developed instrument will be used for high fidelity characterisation and optimisation of the undulators for the ATHOS soft X-ray beamline. The teslameter incorporates analogue signal conditioning for the three-axes interface to a SENIS Hall probe, an interface to a Heidenhain linear absolute encoder and an on-board high-resolution 24-bit analogue-to-digital conversion. This is in contrast to the old instrumentation setup used, which only comprises the analogue circuitry with digitization being done externally to the instrument. The new instrument fits in a volumetric space of 150 mm × 50 mm × 45 mm, being very compact in size and also compatible with the in-vacuum undulators. This paper describes the design and the development of the different components of the teslameter. Performance results are presented that demonstrate offset fluctuation and drift (0.1–10 Hz) with a standard deviation of 0.78 µT and a broadband noise (10–500 Hz) of 2.05 µT with an acquisition frequency of 2 kHz.

13 January 2020 in Electronics
Verified
Journal Article
Open access
PDF file
JCJohann Cassar
Johann Cassar
ASAndrew Sammut
Andrew Sammut
Nicholas SammutNicholas Sammut
Nicholas Sammut
Marco CalviMarco Calvi
Marco Calvi
ZMZarko Mitrovic
Zarko Mitrovic
RPRadivoje S. Popovic
Radivoje S. Popovic
A new reduced form-factor three axes digital teslameter, based on the spinning current technique, has been developed. This instrument will be used to characterize the SwissFEL insertion devices at the Paul Scherrer Institute (PSI) for the ATHOS soft X-ray beamline. A detailed and standardized calibration procedure is critical to optimize the performance of this precision instrument. This paper presents the measurement techniques used for the corrective improvements implemented through non-linearity, temperature offset, temperature sensitivity compensation of the Hall probe and electronics temperature compensation. A detailed quantitative analysis of the reduction in errors on the application of each step of the calibration is presented. The percentage peak error reduction attained through calibration of the instrument for reference fields in the range of ±2 T is registered to drop from 1.94% down to 0.02%.

18 July 2014 in CEAS Aeronautical Journal
Verified
Journal Article
Closed access
PDF file
MMMatthew Micallef
Matthew Micallef
KCKenneth Chircop
Kenneth Chircop
DZDavid Zammit-Mangion
David Zammit-Mangion
ASAndrew Sammut
Andrew Sammut