The magnetic field optimization of RE-Ba-Cu-O (REBCO, RE = rare earth) bulk superconducting undulators is a fundamental step toward their implementation in an accelerator driven photon source, like a synchrotron or a free electron laser. In this article, we propose a sorting algorithm to reduce the undulator’s phase error based on the reconstruction of the trapped current inside the bulks of a staggered array undulator. The results obtained with a YBCO short prototype field-cooled down to 10 K in a 10 T magnetic field are reported. Finally, its performance is critically discussed in light of 2D magnetic field maps of its individual components, obtained at LN 2 after the magnetization tests. Published by the American Physical Society 2024
Most modern outdoor tracking systems utilize GPS technology. However, typical pedestrian environments tend to distort and block satellite signals, thereby making GPS communication systems unreliable. This is particularly true for indoor environments. An alternative pedestrian dead reckoning system based solely on inertial sensors is presented. Noisy acceleration signals result in a heavy velocity drift. This study proposes static-period and dynamic-period compensation methods that would allow for accurate 2-D positioning to be estimated. Data fitting techniques are used to reset velocity drift error after every step, thereby preventing accumulation of errors, as well as to compensate for the errors incurred during the step itself. Results show that the combined system is able to track rectilinear motion under normal walking conditions with an average accuracy of 1.4%, while various lengths of non-linear 2-D paths travelled by different users with varying gaits, paces and directions were successfully tracked with a maximum error of 5%.
A novel three-axis teslameter and other similar machines have been designed and developed for SwissFEL at the Paul Scherrer Institute (PSI). The developed instrument will be used for high fidelity characterisation and optimisation of the undulators for the ATHOS soft X-ray beamline. The teslameter incorporates analogue signal conditioning for the three-axes interface to a SENIS Hall probe, an interface to a Heidenhain linear absolute encoder and an on-board high-resolution 24-bit analogue-to-digital conversion. This is in contrast to the old instrumentation setup used, which only comprises the analogue circuitry with digitization being done externally to the instrument. The new instrument fits in a volumetric space of 150 mm × 50 mm × 45 mm, being very compact in size and also compatible with the in-vacuum undulators. This paper describes the design and the development of the different components of the teslameter. Performance results are presented that demonstrate offset fluctuation and drift (0.1–10 Hz) with a standard deviation of 0.78 µT and a broadband noise (10–500 Hz) of 2.05 µT with an acquisition frequency of 2 kHz.
A new reduced form-factor three axes digital teslameter, based on the spinning current technique, has been developed. This instrument will be used to characterize the SwissFEL insertion devices at the Paul Scherrer Institute (PSI) for the ATHOS soft X-ray beamline. A detailed and standardized calibration procedure is critical to optimize the performance of this precision instrument. This paper presents the measurement techniques used for the corrective improvements implemented through non-linearity, temperature offset, temperature sensitivity compensation of the Hall probe and electronics temperature compensation. A detailed quantitative analysis of the reduction in errors on the application of each step of the calibration is presented. The percentage peak error reduction attained through calibration of the instrument for reference fields in the range of ±2 T is registered to drop from 1.94% down to 0.02%.