Distribution network operators typically produce a report of network performance for all networks as a whole, by not segregating it in a different area; urban and rural networks. Although the report is sufficient, it does not represent the actual performance of each urban and rural networks. Therefore, this paper presents the configurations, parameters, and component rating for medium voltage urban and rural distribution networks. Both networks are assessed with analytical and Monte-Carlo simulation techniques. Each assessment was correlated with Energy Regulator requirements for accurate results. Urban area has better network performance due to sophisticated network automation and network configuration with n-1 or n-2 security compared to the rural area.

19 March 2019 in Energies
Verified
Journal Article
Open access
PDF file
MRMohd Ikhwan Muhammad Ridzuan
Mohd Ikhwan Muhammad Ridzuan
SDSasa Djokic
Sasa Djokic
In conventional reliability analysis, the duration of interruptions relied on the input parameter of mean time to repair (MTTR) values in the network components. For certain criteria without network automation, reconfiguration functionalities and/or energy regulator requirements to protect customers from long excessive duration of interruptions, the use of MTTR input seems reasonable. Since modern distribution networks are shifting towards smart grid, some factors must be considered in the reliability assessment process. For networks that apply reconfiguration functionalities and/or network automation, the duration of interruptions experienced by a customer due to faulty network components should be addressed with an automation switch or manual action time that does not exceed the regulator supply restoration time. Hence, this paper introduces a comprehensive methodology of substituting MTTR with maximum action time required to replace/repair a network component and to restore customer duration of interruption with maximum network reconfiguration time based on energy regulator supply requirements. The Monte Carlo simulation (MCS) technique was applied to medium voltage (MV) suburban networks to estimate system-related reliability indices. In this analysis, the purposed method substitutes all MTTR values with time to supply (TTS), which correspond with the UK Guaranteed Standard of Performance (GSP-UK), by the condition of the MTTR value being higher than TTS value. It is nearly impossible for all components to have a quick repairing time, only components on the main feeder were selected for time substitution. Various scenarios were analysed, and the outcomes reflected the applicability of reconfiguration and the replace/repair time of network component. Theoretically, the network reconfiguration (option 1) and component replacement (option 2) with the same amount of repair time should produce exactly the same outputs. However, in simulation, these two options yield different outputs in terms of number and duration of interruptions. Each scenario has its advantages and disadvantages, in which the distribution network operators (DNOs) were selected based on their operating conditions and requirements. The regulator reliability-based network operation is more applicable than power loss-based network operation in counties that employed energy regulator requirements (e.g., GSP-UK) or areas with many factories that required a reliable continuous supply.

2 January 2020 in SN Applied Sciences
Verified
Journal Article
Closed access
PDF file
MRMohd Ikhwan Muhammad Ridzuan
Mohd Ikhwan Muhammad Ridzuan
NRNur Nabihah Rusyda Roslan
Nur Nabihah Rusyda Roslan
NFNoorFatin Farhanie Mohd Fauzi
NoorFatin Farhanie Mohd Fauzi
MRMuhammad Adib Zufar Rusli
Muhammad Adib Zufar Rusli

1 May 2020 in IOP Conference Series: Materials Science and Engineering
Verified
Conference Paper
Open access
PDF file
NFN F M Fauzi
N F M Fauzi
NRN N R Roslan
N N R Roslan
MRMohd Ikhwan Muhammad Ridzuan
Mohd Ikhwan Muhammad Ridzuan
Reliability is the ability of a system to supply continuous electricity to customer which ends with zero fault that occurs under a specific period of time. Most of the literature focus more on medium voltage (MV) and high voltage (HV) compared to the low voltage (LV) due to the general absence of exact data in LV network and sizing of LV network. In addition, an increament in size of the LV network makes the network more complex and difficult to assess. Therefore, in this paper, the performance of reliability in LV network will be evaluated in detailed network model. To reduce simulation time, methodology of reducing detailed network into an equivalent network is introduced. This equivalent network is obtained by simplifying the complex network using Monte-Carlo Simulation technique. The results in this research are quantified and compared between these detailed and equivalent networks in reliability indices; SAIFI, SAIDI and CAIDI. The values of SAIFI, SAIDI and CAIDI in detailed network are slightly higher than in equivalent network.

24 March 2020
Verified
Book Chapter
Closed access
PDF file
MRMohd Ikhwan Muhammad Ridzuan
Mohd Ikhwan Muhammad Ridzuan
MRMuhammad Adib Zufar Rusli
Muhammad Adib Zufar Rusli
NSNorhafidzah Mohd Saad
Norhafidzah Mohd Saad

1 April 2023 in International Journal of Electrical and Computer Engineering (IJECE)
Verified
Journal Article
Open access
PDF file
NFNoorfatin Farhanie Mohd Fauzi
Noorfatin Farhanie Mohd Fauzi
NRNur Nabihah Rusyda Roslan
Nur Nabihah Rusyda Roslan
MRMohd Ikhwan Muhammad Ridzuan
Mohd Ikhwan Muhammad Ridzuan
Electricity is one of the essential sources for the daily basis activities. The continuous electricity supplied to the customers is one of the main goals for electricity provider. Reliability is one of the main aspects that is focused more on the planning of the power system especially in distribution network. The performance of reliability in the system is evaluated with three main reliability indices: system average interruption frequency index, system average interruption duration index, and customer average interruption duration index. These indices will only give information about the overall condition of the power system without showing the details about the specific of the consumers such as the amount interruptions experienced by customer in the system. In this paper, probability distribution function (PDF) observing the behavior of the components in the system is used in the reliability analysis. Weibull distribution, also known as Weibull family, is one of the most common PDF used in reliability analysis. As Weibull distribution is also related to several distributions, such as exponential and Rayleigh, these types of distributions are applied in the output reliability analysis to observe the performance of reliability in the system. IEEE 9-bus is used as distribution network and carried out using Monte-Carlo simulation.