Florian Schlosser

Dr. Florian Schlosser

Department of Energy System Technologies, Paderborn University, 33098 Paderborn, Germany

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 August 2022 in Renewable and Sustainable Energy Reviews
Verified
Journal Article
Open access
KAKeri-Marie Adamson
Keri-Marie Adamson
TWTimothy Gordon Walmsley
Timothy Gordon Walmsley
James K. CarsonJames K. Carson
James K. Carson
QCQun Chen
Qun Chen
Florian SchlosserFlorian Schlosser
Florian Schlosser
DCDon Cleland
Don Cleland

15 October 2023 in Renewable and Sustainable Energy Reviews
Verified
Journal Article
Open access
TWTimothy Gordon Walmsley
Timothy Gordon Walmsley
MPMatthias Philipp
Matthias Philipp
MPMartín Picón-Núñez
Martín Picón-Núñez
HMHenning Meschede
Henning Meschede
MTMatthew Thomas Taylor
Matthew Thomas Taylor
MAMartin John Atkins
Martin John Atkins

13 November 2023 in Applied Thermal Engineering
Verified
Journal Article
Closed access
LKLana Kong
Lana Kong
TWTimothy Gordon Walmsley
Timothy Gordon Walmsley
DHDuy Khanh Hoang
Duy Khanh Hoang
Florian SchlosserFlorian Schlosser
Florian Schlosser
QCQun Chen
Qun Chen
DCDonald John Cleland
Donald John Cleland

1 March 2018 in Energy
Verified
Journal Article
Closed access
MPMatthias Philipp
Matthias Philipp
GSGregor Schumm
Gregor Schumm
Ron-Hendrik HechelmannRon-Hendrik Hechelmann
Ron-Hendrik Hechelmann
TWTimothy Gordon Walmsley
Timothy Gordon Walmsley
MAMartin Atkins
Martin Atkins
JHJens Hesselbach
Jens Hesselbach

20 May 2019 in Energies
Verified
Journal Article
Open access
PDF file
Ron-Hendrik HechelmannRon-Hendrik Hechelmann
Ron-Hendrik Hechelmann
Florian SchlosserFlorian Schlosser
Florian Schlosser
Henning MeschedeHenning Meschede
Henning Meschede
HDHeiko Dunkelberg
Heiko Dunkelberg
TWTimothy Gordon Walmsley
Timothy Gordon Walmsley
Prerequisite for an efficient cooling energy system is the knowledge and optimal combination of different operating conditions of individual compression and free cooling chillers. The performance of cooling systems depends on their part-load performance and their condensing temperature, which are often not continuously measured. Recorded energy data remain unused, and manufacturers’ data differ from the real performance. For this purpose, manufacturer and real data are combined and continuously adapted to form part-load chiller models. This study applied a predictive optimization algorithm to calculate the optimal operating conditions of multiple chillers. A sprinkler tank offers the opportunity to store cold-water for later utilization. This potential is used to show the load shifting potential of the cooling system by using a variable electricity price as an input variable to the optimization. The set points from the optimization have been continuously adjusted throughout a dynamic simulation. A case study of a plastic processing company evaluates different scenarios against the status quo. Applying an optimal chiller sequencing and charging strategy of a sprinkler tank leads to electrical energy savings of up to 43%. Purchasing electricity on the EPEX SPOT market leads to additional costs savings of up to 17%. The total energy savings highly depend on the weather conditions and the prediction horizon.

29 December 2020 in Energies
Verified
Journal Article
Open access
PDF file
Florian SchlosserFlorian Schlosser
Florian Schlosser
HWHeinrich Wiebe
Heinrich Wiebe
TWTimothy Gordon Walmsley
Timothy Gordon Walmsley
MAMartin Atkins
Martin Atkins
MWMichael R. W. Walmsley
Michael R. W. Walmsley
JHJens Hesselbach
Jens Hesselbach
Heat pumps are the key technology to decarbonise thermal processes by upgrading industrial surplus heat using renewable electricity. Existing insight-based integration methods refer to the idealised Grand Composite Curve requiring the full exploitation of heat recovery potential but leave the question of how to deal with technical or economic limitations unanswered. In this work, a novel Heat Pump Bridge Analysis (HPBA) is introduced for practically targeting technical and economic heat pump potential by applying Coefficient of Performance curves into the Modified Energy Transfer Diagram (METD). Removing cross-Pinch violations and operating heat exchangers at minimum approach temperatures by combined application of Bridge Analysis increases the heat recovery rate and reduce the temperature lift to be pumped at the same time. The insight-based METD allows the individual matching of heat surpluses and deficits of individual streams with the capabilities and performance of different market-available heat pump concepts. For an illustrative example, the presented modifications based on HPBA increase the economically viable share of the technical heat pump potential from 61% to 79%.