Gianpaolo Sannino

Dr. Gianpaolo Sannino


Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Paolo CapparèPaolo Capparè
Paolo Capparè
GSGianpaolo Sannino
Gianpaolo Sannino
MMmargherita minoli
margherita minoli
PMPietro Montemezzi
Pietro Montemezzi
FFFrancesco Ferrini
Francesco Ferrini
Background: The objective of this study was to compare conventional versus digital impressions for Full-Arch maxillary rehabilitations. Methods: Patients selected for this study were treated with full-arch screw-retained rehabilitations supported by six immediately loaded dental implants. Patients have been scheduled randomly into control (conventional impression group, CIG) and test (digital impression group, DIG) groups respectively for a fully conventional workflow and a fully digital workflow. In both groups, within 24 h, temporary prostheses were delivered. Four months after the implant positioning, the two groups dealt with the fabrication of definitive restorations: conventional pick-up was performed in the control group, and definitive digital impressions were carried out in the test group. The time involved following these two procedures was recorded. Patients underwent intraoral digital radiographs to evaluate the accuracy of the framework-implant connection, check for the presence of voids at the bar-implant connection and measure bone level. Criteria used to assess success at the prosthetic level were the occurrence of prosthetic maintenance, the absence of fractures of the acrylic resin superstructure and voids. Results: A total of 50 patients received immediately loaded prostheses supported by six implants (total 300 implants). A fixture and prosthetic survival rate of 100% was observed. All digital X-ray examinations revealed a bar-implant connection accuracy and no voids. Differences that were not statistically significant (p > 0.05) in marginal bone loss were found between control and test groups. Significantly less time was spent to perform digital impression procedure (p < 0.05). Conclusions: Clinical and radiological results of the test group advocate a satisfactory accuracy and predictability of the intraoral scanner (IOS) to be a reliable alternative in clinical practice for implant full-arch rehabilitations and suggest fabrication of definitive restorations with a successful marginal fit precision.

FFFrancesco Ferrini
Francesco Ferrini
GSGianpaolo Sannino
Gianpaolo Sannino
CCCarlo Chiola
Carlo Chiola
Paolo CapparèPaolo Capparè
Paolo Capparè
GGGiorgio Gastaldi
Giorgio Gastaldi
GEGherlone Felice Enrico
Gherlone Felice Enrico
The aim of this in vitro study was to compare the quality of digital workflows generated by different scanners (Intra-oral digital scanners (I.O.S.s)) focusing on marginal fit analysis. A customized chrome-cobalt (Cr-Co) implant abutment simulating a maxillary right first molar was fixed in hemi-maxillary stone model and scanned by eight different I.O.S.s: Omnicam® (Denstply Sirona, Verona, Italy) CS3500®, CS3600®, (Carestream Dental, Atlanta, GA, USA), True Definition Scanner® (3M, St. Paul, MN, USA), DWIO® (Dental Wings, Montreal, Quebec, Canada), PlanScan® (Planmeca Oy, Helsinki, Finland), 3D PROGRESS Plus® (MHT, Verona, Italy), TRIOS 3® (3Shape, Copenhagen, Denmark). Nine scans were performed by each tested I.O.S. and 72 copings were designed using a dental computer-assisted-design/computer-assisted-manufacturing (CAD/CAM) software (exocad GmbH, Darmstadt, Germany). According to CAD data, zirconium dioxide (ZrO2) copings were digitally milled (Roland DWX-50, Irvine, CA, USA). Scanning electron microscope (SEM) direct vision allowed for marginal gap measurements in eight points for each specimen. Descriptive analysis was performed using mean, standard deviation, and median, while the Kruskal–Wallis test was performed to determine whether the marginal discrepancies were significantly different between each group (significance level p < 0.05). The overall mean marginal gap value and standard deviation were 53.45 ± 30.52 μm. The minimum mean value (40.04 ± 18.90 μm) was recorded by PlanScan®, then 3D PROGRESS Plus® (40.20 ± 21.91 μm), True Definition Scanner® (40.82 ± 26.19 μm), CS3500® (54.82 ± 28.86 μm) CS3600® (59,67 ± 28.72 μm), Omnicam® (61.57 ± 38.59 μm), DWIO® (62.49 ± 31.54 μm), while the maximum mean value (67.95 ± 30.41 μm) was recorded by TRIOS 3®. The Kruskal–Wallis tests revealed a statistically significant difference (p-value < 0.5) in the mean marginal gaps between copings produced by 3D PROGRESS Plus®, PlanScan, True Definition Scanner, and the other evaluated I.O.S.s. The use of an I.O.S. for digital impressions may be a viable alternative to analog techniques. Although in this in vitro study PlanScan®, 3D PROGRESS Plus® and True Definition Scanner® may have showed the best performances, all I.O.S.s tested could provide clinically encouraging results especially in terms of marginal accuracy, since mean marginal gap values were all within the clinically acceptable threshold of 120 μm.

1 April 2015 in Journal of Oral Implantology
Verified
Journal Article
Closed access
GSGianpaolo Sannino
Gianpaolo Sannino
The aim of this work was to study the biomechanical behavior of an All-on-4 implant-supported prosthesis through a finite element analysis comparing 3 different tilt degrees of the distal implants. Three-dimensional finite element models of an edentulous maxilla restored with a prosthesis supported by 4 implants were reconstructed to carry out the analysis. Three distinct configurations, corresponding to 3 tilt degrees of the distal implants (15°, 30°, and 45°) were subjected to 4 loading simulations. The von Mises stresses generated around the implants were localized and quantified for comparison. Negligible differences in von Mises stress values were found in the comparison of the 15° and 30° models. From a stress-level viewpoint, the 45° model was revealed to be the most critical for peri-implant bone. In all the loading simulations, the maximum stress values were always found at the neck of the distal implants. The stress in the distal implants increased in the apical direction as the tilt degree increased. The stress location and distribution patterns were very similar among the evaluated models. The increase in the tilt degree of the distal implants was proportional to the increase in stress concentration. The 45° model induced higher stress values at the bone-implant interface, especially in the distal aspect, than the other 2 models analyzed.

19 June 2013 in Computational and Mathematical Methods in Medicine
Verified
Journal Article
Open access
PDF file
GVGiuseppe Vairo
Giuseppe Vairo
GSGianpaolo Sannino
Gianpaolo Sannino
This study aimed to investigate the influence of implant design (in terms of diameter, length, and thread shape), in-bone positioning depth, and bone posthealing crestal morphology on load transfer mechanisms of osseointegrated dental implants based on platform-switching concept. In order to perform an effective multiparametric comparative analysis, 11 implants different in dimensions and in thread features were analyzed by a linearly elastic 3-dimensional finite element approach, under a static load. Implant models were integrated with the detailed model of a maxillary premolar bone segment. Different implant in-bone positioning levels were modeled, considering also different posthealing crestal bone morphologies. Bone overloading risk was quantified by introducing proper local stress measures, highlighting that implant diameter is a more effective design parameter than the implant length, as well as that thread shape and thread details can significantly affect stresses at peri-implant bone, especially for short implants. Numerical simulations revealed that the optimal in-bone positioning depth results from the balance of 2 counteracting effects: cratering phenomena and bone apposition induced by platform-switching configuration. Proposed results contribute to identify the mutual influence of a number of factors affecting the bone-implant loading transfer mechanisms, furnishing useful insights and indications for choosing and/or designing threaded osseointegrated implants.

1 January 2013 in The International Journal of Oral and Maxillofacial Implants
Verified
Journal Article
Closed access
GSGianpaolo Sannino
Gianpaolo Sannino
ABAlberto Barlattani
Alberto Barlattani
Gianpaolo Sannino, DDS, PhD/Alberto Barlattani, MD, MsC, PhD: Purpose: To evaluate the mechanical properties and behavior of a self-locking taper connection with three different techniques: three-dimensional finite element analysis (FEA), ultimate failure loading, and cyclic loading analysis. Materials and Methods: The implant-abutment complex was embedded vertically in the center of an acrylic resin support block (Young?s modulus > 3 GPa). All materials used in this study were assumed to be homogenous and isotropic, but while the resin was assumed to be linearly elastic, the titanium was assumed to have a multilinear behavior to better represent the implant system in its plastic phase and to compare as closely as possible the numeric simulation with the experimental tests. An 800-N 30-degree off-axis load was applied to the occlusal surface of the abutment. In addition to the FEA, static and dynamic tests were carried out. Results: The greatest von Mises stresses were concentrated in the coronal portion of the abutment?s tapered connection, while at the implant neck they were lower and less extensive than the abutment ones. Experimental results confirmed the FEA findings, in which the structural limit of the system was reached, with permanent deformation of the abutment that exceeded a predefined limit, rather than fracture. Conclusion: Within the limitations of the reported analyses, these static and dynamic tests appear to supply congruent results, thus allowing evaluation of the mechanical behavior of a self-locking taperedconnection implant system. High resistance to an off-axis load was exhibited, exceeding that usually offered by screw-retained implant systems, thus indicating good stability of the implant-abutment connection. Int J Oral Maxillofac Implants 2013;28:e17?e26. doi: 10.11607/jomi.2058

30 November 2015 in Journal of Prosthodontics
Verified
Journal Article
Closed access
PDF file
GSGianpaolo Sannino
Gianpaolo Sannino
PBPatrizio Bollero
Patrizio Bollero
ABAlberto Barlattani
Alberto Barlattani
GEGherlone Felice Enrico
Gherlone Felice Enrico