Giorgio Gastaldi

Prof. Dr. Giorgio Gastaldi

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
FFFrancesco Ferrini
Francesco Ferrini
GSGianpaolo Sannino
Gianpaolo Sannino
CCCarlo Chiola
Carlo Chiola
Paolo CapparèPaolo Capparè
Paolo Capparè
GGGiorgio Gastaldi
Giorgio Gastaldi
GEGherlone Felice Enrico
Gherlone Felice Enrico
The aim of this in vitro study was to compare the quality of digital workflows generated by different scanners (Intra-oral digital scanners (I.O.S.s)) focusing on marginal fit analysis. A customized chrome-cobalt (Cr-Co) implant abutment simulating a maxillary right first molar was fixed in hemi-maxillary stone model and scanned by eight different I.O.S.s: Omnicam® (Denstply Sirona, Verona, Italy) CS3500®, CS3600®, (Carestream Dental, Atlanta, GA, USA), True Definition Scanner® (3M, St. Paul, MN, USA), DWIO® (Dental Wings, Montreal, Quebec, Canada), PlanScan® (Planmeca Oy, Helsinki, Finland), 3D PROGRESS Plus® (MHT, Verona, Italy), TRIOS 3® (3Shape, Copenhagen, Denmark). Nine scans were performed by each tested I.O.S. and 72 copings were designed using a dental computer-assisted-design/computer-assisted-manufacturing (CAD/CAM) software (exocad GmbH, Darmstadt, Germany). According to CAD data, zirconium dioxide (ZrO2) copings were digitally milled (Roland DWX-50, Irvine, CA, USA). Scanning electron microscope (SEM) direct vision allowed for marginal gap measurements in eight points for each specimen. Descriptive analysis was performed using mean, standard deviation, and median, while the Kruskal–Wallis test was performed to determine whether the marginal discrepancies were significantly different between each group (significance level p < 0.05). The overall mean marginal gap value and standard deviation were 53.45 ± 30.52 μm. The minimum mean value (40.04 ± 18.90 μm) was recorded by PlanScan®, then 3D PROGRESS Plus® (40.20 ± 21.91 μm), True Definition Scanner® (40.82 ± 26.19 μm), CS3500® (54.82 ± 28.86 μm) CS3600® (59,67 ± 28.72 μm), Omnicam® (61.57 ± 38.59 μm), DWIO® (62.49 ± 31.54 μm), while the maximum mean value (67.95 ± 30.41 μm) was recorded by TRIOS 3®. The Kruskal–Wallis tests revealed a statistically significant difference (p-value < 0.5) in the mean marginal gaps between copings produced by 3D PROGRESS Plus®, PlanScan, True Definition Scanner, and the other evaluated I.O.S.s. The use of an I.O.S. for digital impressions may be a viable alternative to analog techniques. Although in this in vitro study PlanScan®, 3D PROGRESS Plus® and True Definition Scanner® may have showed the best performances, all I.O.S.s tested could provide clinically encouraging results especially in terms of marginal accuracy, since mean marginal gap values were all within the clinically acceptable threshold of 120 μm.

13 June 2022 in Progress in Orthodontics
Verified
Journal Article
Open access
PDF file
Antonino Lo GiudiceAntonino Lo Giudice
Antonino Lo Giudice
VRVincenzo Ronsivalle
Vincenzo Ronsivalle
GGGiorgio Gastaldi
Giorgio Gastaldi
Rosalia Maria LeonardiRosalia Maria Leonardi
Rosalia Maria Leonardi
Background: Several semi-automatic software are available for the three-dimensional reconstruction of the airway from DICOM files. The aim of this study was to evaluate the accuracy of the segmentation of the upper airway testing four free source and one commercially available semi-automatic software. A total of 20 cone-beam computed tomography (CBCT) were selected to perform semi-automatic segmentation of the upper airway. The software tested were Invesalius, ITK-Snap, Dolphin 3D, 3D Slicer and Seg3D. The same upper airway models were manually segmented (Mimics software) and set as the gold standard (GS) reference of the investigation. A specific 3D imaging technology was used to perform the superimposition between the upper airway model obtained with semi-automatic software and the GS model, and to perform the surface-to-surface matching analysis. The accuracy of semi-automatic segmentation was evaluated calculating the volumetric mean differences (mean bias and limits of agreement) and the percentage of matching of the upper airway models compared to the manual segmentation (GS). Qualitative assessments were performed using color-coded maps. All data were statistically analyzed for software comparisons. Results: Statistically significant differences were found in the volumetric dimensions of the upper airway models and in the matching percentage among the tested software (p < 0.001). Invesalius was the most accurate software for 3D rendering of the upper airway (mean bias = 1.54 cm3; matching = 90.05%) followed by ITK-Snap (mean bias = − 2.52 cm3; matching = 84.44%), Seg 3D (mean bias = 3.21 cm3, matching = 87.36%), 3D Slicer (mean bias = − 4.77 cm3; matching = 82.08%) and Dolphin 3D (difference mean = − 6.06 cm3; matching = 78.26%). According to the color-coded map, the dis-matched area was mainly located at the most anterior nasal region of the airway. Volumetric data showed excellent inter-software reliability (GS vs semi-automatic software), with coefficient values ranging from 0.904 to 0.993, confirming proportional equivalence with manual segmentation. Conclusion: Despite the excellent inter-software reliability, different semi-automatic segmentation algorithms could generate different patterns of inaccuracy error (underestimation/overestimation) of the upper airway models. Thus, is unreasonable to expect volumetric agreement among different software packages for the 3D rendering of the upper airway anatomy.

27 February 2023 in Dentistry Journal
Verified
Journal Article
Open access
PDF file
Francesca CattoniFrancesca Cattoni
Francesca Cattoni
LFlucrezia Ferrante
lucrezia Ferrante
SMSara Mandile
Sara Mandile
GTGiulia Tetè
Giulia Tetè
EPElisabetta Maria Polizzi
Elisabetta Maria Polizzi
GGGiorgio Gastaldi
Giorgio Gastaldi
The main objective of this review is to verify the validity of laser therapy in the treatment of dentin hypersensitivity, an extremely common problem in patients, with Nd: YAG lasers or high- and/or low-power diode lasers to obtain a definitive protocol for the treatment of hypersensitivity, given the multiplicity of laser treatments proposed by the numerous authors evaluated. The authors performed an electronic search on PubMed, favouring it as a search engine. Lasers represent a means of treating dentin hypersensitivity, used alone and/or in conjunction with specific products for the treatment of such a pathology. The selected articles that examined diode lasers were divided according to the wattage (w) used: low-level laser therapy protocols, i.e., those using a wattage of less than 1 W, and high-level laser therapy protocols, i.e., those using a wattage of 1 W or more. Regarding the Nd: YAG laser, it was not necessary to subdivide the studies in this way, as they used a wattage of 1 W or more. A total of 21 articles were included in the final selection. Laser therapy was found to be effective in the treatment of dentin hypersensitivity. However, the level of effectiveness depends on the laser used. The results obtained from this review show that both the Nd: YAG laser and the diode laser (high and low power) are effective in the treatment of dentin hypersensitivity. However, the high-power laser appears to be more effective in combination with fluoride varnish and the Nd: YAG laser achieved greater long-term benefits than the diode laser.

25 April 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Gaetano PaoloneGaetano Paolone
Gaetano Paolone
MMMauro Mandurino
Mauro Mandurino
SBSofia Baldani
Sofia Baldani
MPMaria Giacinta Paolone
Maria Giacinta Paolone
Cecilia GoracciCecilia Goracci
Cecilia Goracci
GGGiorgio Gastaldi
Giorgio Gastaldi
Objectives: To conduct a systematic review assessing quantitative enamel loss occurring after orthodontic debonding and clean-up procedures. Materials and Methods: A systematic search following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement was performed on different databases (Embase, Medline, Scopus, Web of Science) for papers investigating volumetric enamel loss due to bracket and clear aligner attachment debonding and/or clean-up procedures. Studies investigating in vivo and in vitro articles published in the English language until 16 July 2022 were included. The study selection was then performed by two authors who screened the abstracts independently. Results: Of 421 screened abstracts, 41 articles were selected for full-text analysis. Finally, nine studies were included in this review. No in vivo papers were retrieved. In vitro papers investigated volumetric loss caused by the removal of metal brackets (n = 7), ceramic brackets (n = 1), and both (n = 1). The clean-up procedure varied among all investigations. Impressions at baseline and after debonding/clean-up were superimposed, and the volumes were subtracted using different 3D digital analysis software. Among all included studies, the volumetric loss of enamel ranged from 0.02 ± 0.01 mm3 to 0.61 ± 0.51 mm3 per tooth. Conclusions: Debonding and clean-up procedures produce enamel loss. The debonding/clean-up procedure that is able to cause the least enamel volume loss has yet to be identified.

8 April 2024 in The Korean Journal of Orthodontics
Verified
Journal Article
Open access
PDF file
MMMarco Migliorati
Marco Migliorati
SDSara Drago
Sara Drago
Tommaso CastroflorioTommaso Castroflorio
Tommaso Castroflorio
Paolo PescePaolo Pesce
Paolo Pesce
GBGiovanni Battista
Giovanni Battista
AMAnna De Mari
Anna De Mari
Marco Migliorati, Sara Drago, Tommaso Castroflorio, Paolo Pesce, Giovanni Battista, Alessandra Campobasso, Giorgio Gastaldi, Filippo Forin Valvecchi, Anna De Mari. Korean J Orthod 2024;54:160-70. https://doi.org/10.4041/kjod23.268

ARAndrea Rampi
Andrea Rampi
Alessandro VinciguerraAlessandro Vinciguerra
Alessandro Vinciguerra
SBStefano Bondi
Stefano Bondi
NPNicoletta Stella Policaro
Nicoletta Stella Policaro
GGGiorgio Gastaldi
Giorgio Gastaldi
Cocaine abuse is associated with severe local effects on mucosal and osteocartilaginous structures, with a centrifugal spreading pattern from the nose, a condition known as cocaine-induced midline destructive lesions (CIMDL). When the soft or hard palate is affected, a perforation may occur, with subsequent oro-nasal reflux and hypernasal speech. Both diagnosis and therapy (surgical or prosthetic) constitute a serious challenge for the physician. The cases of three patients affected by cocaine-induced palatal perforation and treated with a palatal obturator at San Raffaele Dentistry department between 2016 and 2019 are presented. In addition, the literature was reviewed in search of papers reporting the therapeutic management in patients affected by cocaine-induced palatal perforation. All the patients in our sample suffered from oro-nasal reflux and hypernasal speech, and reported a significant impact on interpersonal relationships. The results at the delivery of the obturator were satisfactory, but the duration of such results was limited in two cases, as the progression of the disease necessitated continuous modifications of the product, with a consequent increase in costs and a reduction in patient satisfaction. In conclusion, the therapy for palatal defects in CIMDL includes both reconstructive surgery and prosthetic obturators, the latter being the only possibility in the event of active disease. It successfully relieves symptoms, but the long-term efficacy is strongly related to the level of disease activity.