The worldwide demand on data storage continues to increase and both the number and the size of data centers are expanding rapidly. Energy efficiency is an important factor to consider in data centers since the total energy consumption is huge. The servers must be cooled and the performance of the cooling system depends on the flow field of the air. Computational Fluid Dynamics (CFD) can provide detailed information about the airflow in both existing data centers and proposed data center configurations before they are built. However, the simulations must be carried out with quality and trust. The k– model is the most common choice to model the turbulent airflow in data centers. The aim of this study is to examine the performance of more advanced turbulence models, not previously investigated for CFD modeling of data centers. The considered turbulence models are the k– model, the Reynolds Stress Model (RSM) and Detached Eddy Simulations (DES). The commercial code ANSYS CFX 16.0 is used to perform the simulations and experimental values are used for validation. It is clarified that the flow field for the different turbulence models deviate at locations that are not in the close proximity of the main components in the data center. The k– model fails to predict low velocity regions. RSM and DES produce very similar results and, based on the solution times, it is recommended to use RSM to model the turbulent airflow data centers.
1 August 2011 in International Journal of Heat and Mass Transfer
Drying of a porous bed of iron ore pellets is here considered by modeling a discrete two-dimensional system of round pellets. As a complement to the two-dimensional model, a continuous one-dimensional model enabling fast calculations is developed. Results from the discrete model show that the temperature front advances faster in areas with large distances between the pellets. In areas with low flow speed, the temperature of the pellets increases with a relatively slow rate. The water inside these pellets will therefore remain for a long time. The continuous model fits the discrete model very well for a regular distribution of equal-sized particles. A discrete model with irregular packing will, compared to the continuous model, show a larger variation in the distribution of temperature and moisture content in the final phase of drying.
5 January 2016 in Journal of Reinforced Plastics and Composites
In this work, the temperature distribution on an industrial mold tool is monitored during autoclave runs with three settings. In one of the settings, the temperature and pressure follow a scheme used in real moldings, while in the other two cases, the temperature is increased as fast as possible with and without an applied pressure. The temperature difference over the tool is relatively large and varies between 29℃ and 76℃ validating a detailed investigation of the temperature at different points. Two results of this are that positions on the up-stream side of the tool are heated faster than positions down-stream and the heating over the tool is symmetric while that within is asymmetric. Roughly estimated heat transfer coefficients reveal that the temperature ramping has no significant effect on the local heat transfer coefficients while the applied pressure more than doubled them. In addition flow field measurements with particle image velocimetry are performed, revealing a very slow flow near the roof of the autoclave and a velocity peak near the floor of it, indicating that the flow profile within the autoclave and variation in heat transfer coefficients should be considered in autoclave simulations.