Qiufeng Yan

Dr. Qiufeng Yan

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 July 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
QYQiufeng Yan
Qiufeng Yan
YYYongkang Yin
Yongkang Yin
WSWanting Sun
Wanting Sun
JFJun Fu
Jun Fu
Piezoelectric pump design is regarded as a hot research topic in the microfluidic field, and has been applied in liquid cooling, precision machinery and other relevant domains. The valveless piezoelectric pump becomes an important branch of the piezoelectric pump, because it successfully avoids the problem of “pump-lagging of valve” during the valve piezoelectric pump processing. This paper summarizes the development of valveless piezoelectric pumps, and introduces some different configurations of valveless piezoelectric pumps. The structure and material of all kinds of valveless piezoelectric pumps are elaborated in detail, and also the output performance of the pump is evaluated and analyzed with the variations in flow rate and output pressure as reference. By comparing the flow of different types of valveless piezoelectric pumps, the application of valveless piezoelectric pumps is also illustrated. The development tendency of the valveless piezoelectric pump is prospected from the perspective of structure design and machining methods, which is expected to provide novel ideas and guidance for future research.

2 April 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
QYQiufeng Yan
Qiufeng Yan
WSWanting Sun
Wanting Sun
JZJianhui Zhang
Jianhui Zhang
On the basis of previous study in our research group, the phenomenon of the dynamic tapered angle was founded, the occurrence of atomization is regarded to derive from the combined effects of the dynamic variation of the micro-tapered aperture, and the difference between forward and reverse flow resistance has been explained by both theories and experiments. It has been revealed that the main influencing factors of the atomization rate are driving voltage, driving frequency, and so on, while the root causes of the various atomization rates still need to be further clarified. In this paper, a micro-tapered aperture worked as a micron-sized tapered flow tube valveless piezoelectric pump in periodic variation. The working principle of such a micro-tapered aperture atomizer was analyzed in detail, and the corresponding formula of the atomization rate was also established. Through measuring the atomization rates at different working frequencies (f), it was established that when the f was set as 122 kHz, the atomization rate reached a maximum value. By building the relationship between the atomization rate and voltage at a fixed resonance frequency, it can be seen that the atomization rate increased with the increase of driving voltage. Subsequently, in order to measure their atomization rates, the micro-tapered apertures of three different outlet diameters were applied, so that the atomization rate was enhanced with the increase of the micro-tapered aperture diameter. Moreover, through examining the atomization rates at different temperatures, it was observed that the atomization rate rose with increasing temperature; while changing the liquid concentration, the atomization rate was also enhanced by the increase in its concentration. Apparently, the impact factors including working frequency, driving voltage, outlet diameter, temperature, and liquid concentration all exert some effects on the atomization rate. It is worth noting that at the first stage, these influence factors indirectly work on the micro-tapered aperture structure or flow state, followed by further effects on the flow resistance. As above-mentioned, in this work, we considered that the root cause influencing the atomization rate in a piezoceramic vibrating mesh atomizer can be attributed to the flow resistance.

3 May 2019 in Applied Sciences
Verified
Journal Article
Open access
PDF file
QYQiufeng Yan
Qiufeng Yan
Charley WuCharley Wu
Charley Wu
JZJianhui Zhang
Jianhui Zhang
In this paper, we find that the dynamic cone angle of a piezoceramic atomizer is linked to periodic changes in the volume of the micro-cone hole of the atomizer, and such changes affect atomization performance. Firstly, we explained the theory of the dynamic cone angle inside the vibrating mesh atomizer. Then, we analyzed the flow status of liquid in the micro-cone hole, and the one-way flow Rof the liquid is caused by the difference of diffuser and nozzle flow resistance. The volume change of the micro-cone hole and the liquid chamber can produce atomization. Furthermore, we developed the experiment to measure the atomization rate, atomization height, and the diameter of the atomized particles. The experiments reveal that the atomization rate and height are much larger when the vibrating mesh atomizer is working in the forward path than in the reverse one. The atomization rate and atomization height increase as the working voltage increases. Meanwhile, with increasing driving voltage to the piezoceramic actuator, the atomization particle size decrease and the atomized particle size distribution is more concentrated. Finally, the size of the micro-cone hole was measured using a microscope with different direct current (DC) voltages, further demonstrating the existence of the dynamic cone angle.

17 July 2018 in Sensors
Verified
Journal Article
Open access
PDF file
JZJianhui Zhang
Jianhui Zhang
QYQiufeng Yan
Qiufeng Yan
Jun HuangJun Huang
Jun Huang
Charley WuCharley Wu
Charley Wu
In this study, we examined the use of a dynamic micro-tapered hole as a micro-scale tapered flow tube valveless piezoelectric pump. Firstly, we obtained photographs of a micro-tapered hole by using an environmental scanning electron microscope (ESEM). Then, we explained the pump effect of the micro-tapered hole, and derived the atomization rate equation. Furthermore, we reported an atomization rate measurement experiment that eliminated the atomization caused by a pressure increase, and demonstrated that a change in the volume of a micro-tapered hole could produce atomization. The experimental results indicate that, under the same voltage, the forward atomization rate is much higher than the reverse atomization rate and that the atomization rate increases with the micro-tapered hole volume. The experimental results show that the atomization of the micro-tapered aperture atomizer is caused by its pumping effect. Moreover, the flow resistance and volume of the micro-tapered hole can affect the atomization rate.

31 May 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
QYQiufeng Yan
Qiufeng Yan
JYJiahan You
Jiahan You
WSWanting Sun
Wanting Sun
YWYing Wang
Ying Wang
HWHongmei Wang
Hongmei Wang
Lei ZhangLei Zhang
Lei Zhang
In recent years, the piezoelectric jet and atomization devices have exhibited tremendous advantages including their simple construction, and the fact that they are discreet and portable as well as low cost. They have been widely used in cell printing, spray cooling, drug delivery, and other industry fields. First, in this paper, two different concepts of jet and atomization are defined, respectively. Secondly, based on these two concepts, the piezoelectric jet and atomization devices can be divided into two different categories: piezoelectric micro jet device and piezoelectric atomization device. According to the organizational structure, piezoelectric micro jet devices can be classified into four different models: bend mode, push mode, squeeze mode, and shear mode. In addition, their development history and structural characteristics are summarized, respectively. According to the location of applied energy, there are two kinds of piezoelectric atomization devices, i.e., the static mesh atomization device and the vibration mesh atomization device, and both their advantages and drawbacks are discussed. The research achievements are summarized in three aspects of cell printing, spray cooling, and drug delivery. Finally, the future development trends of piezoelectric jet and atomization devices are prospected and forecasted.

4 December 2021 in Chinese Journal of Mechanical Engineering
Verified
Journal Article
Open access
PDF file
QYQiufeng Yan
Qiufeng Yan
WSWanting Sun
Wanting Sun
Lei ZhangLei Zhang
Lei Zhang
HWHongmei Wang
Hongmei Wang
JZJianhui Zhang
Jianhui Zhang
Oral inhalation of aerosolized drugs has be widely applied in healing the affected body organs including lesions of the throat and lungs and it is more efficient than those conventional therapies, such as intravenous drip, intramuscular injection and external topical administration in the aspects of the dosage reduction and side effects of drugs. Nevertheless, the traditional atomization devices always exhibit many drawbacks. For example, non-uniformed atomization particle distribution, the instability of transient atomization quantity and difficulties in precise energy control would seriously restrict an extensive use of atomization inhalation therapy. In this study, the principle of intra-hole fluctuation phenomenon occurred in the hole is fully explained, and the produced volume change is also estimated. Additionally, the mathematical expression of the atomization rate of the atomizing device is well established. The mechanism of the micro-pump is further clarified, and the influence of the vibration characteristics of the atomizing film on the atomization behavior is analyzed theoretically. The curves of sweep frequency against the velocity and amplitude of the piezoelectric vibrator are obtained by the Doppler laser vibrometer, and the corresponding mode shapes of the resonance point are achieved. The influence of vibration characteristics on atomization rate, atomization height and atomization particle size are also verified by experiments, respectively. Both the experimental results and theoretical calculation are expected to provide a guidance for the design of this kind of atomization device in the future.