choi kilyong

Dr. choi kilyong


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 May 2019 in BMC Public Health
Verified
Journal Article
Open access
PDF file
JKJeonghoon Kim
Jeonghoon Kim
MJMijung Jang
Mijung Jang
CKchoi kilyong
choi kilyong
KKKyooSang Kim
KyooSang Kim
We examined the indoor air quality (IAQ) perceptions of workers and their relationships with the symptoms of sick-building syndrome (SBS) and store types in underground shopping centers. In 2017, 314 store workers in nine underground shopping centers in Seoul, Korea, were assessed. The all participants’ stores were partially opened onto a passage. Using questionnaires, they were asked about their demographics, job characteristics, 16 SBS symptoms, and seven IAQ perceptions. The SBS symptoms were categorized as skin, eye irritation, respiratory, or general. An IAQ perception score was calculated by adding the number of positive responses to each type of IAQ and categorized into three levels. The prevalence of SBS symptom groups in the previous month was 43.6% for skin symptoms, 62.4% for eye irritation symptoms, 65.6% for respiratory symptoms, and 64.7% for general symptoms. Participants who perceived IAQ were more likely to have SBS symptoms (odds ratio: 1.81–7.84). The type of store employing the workers was associated with several IAQ perceptions. Subjects who worked in clothing and fashion-accessory stores were more likely to have high IAQ perception scores than those who worked in food services. About half of the store workers in underground shopping centers had experienced SBS symptom groups in the previous month. The SBS symptom groups were associated with almost all IAQ perceptions. Because IAQ perception was associated with store type, studies of IAQ in working areas might need to improve store workers’ health in underground shopping centers.

ECEunmin Cho
Eunmin Cho
HJHyungjin Jeon
Hyungjin Jeon
DYDan Ki Yoon
Dan Ki Yoon
SPSi Hyun Park
Si Hyun Park
HHHyong JIn Hong
Hyong JIn Hong
Lee Cheol MinLee Cheol Min
Lee Cheol Min
Currently, low-cost, sensor-based fine dust measurement devices are commercially available in South Korea. This study evaluated the reliability of three such devices—Yi Shan A4, Plantower PMS7003, and Plantower PMS7003—in comparison to long-term consecutive monitoring systems for discharge and prevention facilities regarding fine dust control. The performance of these devices for concentration intervals over time was examined through real-time comparison using a GRIMM (Model: 11-A, dust spectrometer from Grimm Technologies) as a reference; this included a correction factor (C-Factor), calculated by a gravimetric method and an equivalence test. For comparison, the reference and target devices were installed in a chamber with fine dust concentrations of 2 µg/m3, with temperature and humidity maintained at 20 °C and 40%, respectively. The fine particulate matter (PM)2.5 concentrations were classified into five intervals: ≤40 µg/m3, 40–80 µg/m3, 80–120 µg/m3, 120–160 µg/m3, and 200–230 µg/m3. Statistical analysis was performed using data obtained from national stations for monitoring and controlling fine dust released from facilities under high fine dust loading conditions. The results showed that the measurements of all target devices, which were corrected according to the reference device, provided accurate values at PM2.5 concentrations of ≥40 µg/m3. The statistical analysis results suggest that the evaluated devices are more reliable than the conventional numerical-analysis-based monitoring system