Tommaso Bragatto

Dr. Tommaso Bragatto

Department of Astronautics, Electric and Energy Engineering, “Sapienza” University of Rome, 00184 Rome, Italy
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2021 in Energy Reports
Verified
Journal Article
Open access
CAClaudia Antal
Claudia Antal
Tudor CioaraTudor Cioara
Tudor Cioara
MAMarcel Antal
Marcel Antal
VMVlad Mihailescu
Vlad Mihailescu
DMDan Mitrea
Dan Mitrea
FBFrancesco Bellesini
Francesco Bellesini

2 August 2023 in Sustainable Energy, Grids and Networks
Verified
Journal Article
Open access
Tommaso BragattoTommaso Bragatto
Tommaso Bragatto
MBMarco Antonio Bucarelli
Marco Antonio Bucarelli
FCFederico Carere
Federico Carere
MCM. Cresta
M. Cresta
FGF.M. Gatta
F.M. Gatta
FSF. Santori
F. Santori

17 June 2021 in Energies
Verified
Journal Article
Open access
PDF file
Paraskevas KoukarasParaskevas Koukaras
Paraskevas Koukaras
PGPaschalis Gkaidatzis
Paschalis Gkaidatzis
ΝΜΝαπολέων Μπέζας
Ναπολέων Μπέζας
Tommaso BragattoTommaso Bragatto
Tommaso Bragatto
FCFederico Carere
Federico Carere
DTDimitrios Tzovaras
Dimitrios Tzovaras
Over the past few decades, industry and academia have made great strides to improve aspects related with optimal energy management. These include better ways for efficient energy asset management, generating great opportunities for optimization of energy distribution, discomfort minimization, energy production, cost reduction and more. This paper proposes a framework for a multi-objective analysis, acting as a novel tool that offers responses for optimal energy management through a decision support system. The novelty is in the structure of the methodology, since it considers two distinct optimization problems for two actors, consumers and aggregators, with solution being able to completely or partly interact with the other one is in the form of a demand response signal exchange. The overall optimization is formulated by a bi-objective optimization problem for the consumer side, aiming at cost minimization and discomfort reduction, and a single objective optimization problem for the aggregator side aiming at cost minimization. The framework consists of three architectural layers, namely, the consumer, aggregator and decision support system (DSS), forming a tri-layer optimization framework with multiple interacting objects, such as objective functions, variables, constants and constraints. The DSS layer is responsible for decision support by forecasting the day-ahead energy management requirements. The main purpose of this study is to achieve optimal management of energy resources, considering both aggregator and consumer preferences and goals, whilst abiding with real-world system constraints. This is conducted through detailed simulations using real data from a pilot, that is part of Terni Distribution System portfolio.

11 September 2019 in Energies
Verified
Journal Article
Open access
PDF file
Tommaso BragattoTommaso Bragatto
Tommaso Bragatto
ACAlberto Cerretti
Alberto Cerretti
LDLuigi D'Orazio
Luigi D'Orazio
FGFabio M. Gatta
Fabio M. Gatta
Alberto GeriAlberto Geri
Alberto Geri
MMMarco Maccioni
Marco Maccioni
In recent years, an anomalous increase of faults in underground medium voltage (MV) cable lines has been recorded in Italy, especially during summer; the largest number of faults affected cable joints. The assessment of joint thermal stress, both in normal operation and during faults, is paramount. The study presented in this paper focuses on cable heating effects due to short circuit currents flowing through cable screens during ground faults (e.g., in case of cross country faults, CCFs, whose current values are comparable to line-to-line short circuit), considering the contact resistance (CR) between cable screens and copper stocking due to inaccurate joint manufacturing. A thermal model, already developed and discussed by the authors in previous papers, has been extended and applied in this study in order to assess the CR effects in cable and joint heating during failures. Parametric studies have been carried out on a typical cable-joint system, varying fault current and CR values, as well as considering protection schemes normally adopted by distribution system operators (DSOs) in Italian MV distribution grids. Results show that for CR values larger than few milliohms, fault currents due to CCFs are able to overheat the joint well beyond the maximum tolerable temperature of insulation, thus leading to cable failures when the shortest fault clearing times (i.e., 120 ms) are considered.

23 February 2019 in Energies
Verified
Journal Article
Open access
PDF file
Tommaso BragattoTommaso Bragatto
Tommaso Bragatto
MCMassimo Cresta
Massimo Cresta
FCFabrizio Cortesi
Fabrizio Cortesi
FGFabio M. Gatta
Fabio M. Gatta
Alberto GeriAlberto Geri
Alberto Geri
MPMarco Paulucci
Marco Paulucci
In recent years, because of increasing frequency and magnitude of extreme weather events, the main stakeholders of electric power systems are emphasizing issues about resilience. Whenever networks are designed and development plans are drawn, this new feature must be assessed and implemented. In this paper, a procedure to evaluate the resilience of a distribution network against flooding threats is presented. Starting from a detailed analysis about the resilience of each asset of the grid, the procedure implements the exploration of the network in order to evaluate the impact of interruptions (e.g., in terms of number of disconnected users) produced by the specific threat; then, it calculates the resilience indices of the whole system. The procedure is applied with respect to the flooding threats, on a real distribution network in the center of Italy (i.e., the distribution network of Terni). Referring to this case study, the proposed method suggests countermeasures able to reduce the impact of flooding events and evaluates their benefits. Results indicate that, at the present time, the network is adequately resilient with respect to flooding events, as demonstrated by the index values. However, the remedial actions identified by the procedure are also able to improve the resilience of the network and, in addition, they are in agreement with the development plan already established by the distribution system operator (DSO).

20 May 2023 in Electric Power Systems Research
Verified
Journal Article
Open access
Tommaso BragattoTommaso Bragatto
Tommaso Bragatto
FCFederico Carere
Federico Carere
MCM. Cresta
M. Cresta
FGF.M. Gatta
F.M. Gatta
AGA. Geri
A. Geri
MPM. Paulucci
M. Paulucci