The penetration of renewable energy sources (RESs) equipped with inverter-based control systems such as wind and solar plants are increasing. Therefore, the speed of the voltage controllers associated with inverter-based resources (IBRs) has a substantial impact on the stability of the interconnected grid. System strength evaluation is one of the important concerns in the integration of IBRs, and this strength is often evaluated in terms of the short circuit ratio (SCR) index. When IBRs are installed in an adjacent location, system strength can be weaker than evaluation by SCR. This study proposes an inverter interaction level short circuit ratio (IILSCR) method by tracing IBRs output flow. The IILSCR can accurately estimate system strength, wherein IBRs are connected in adjacent spots, by reflecting the interaction level between IBRs. The study also demonstrates the efficiency of IILSCR by applying this method to Institute of Electrical and Electronics Engineers (IEEE) 39 bus test system and future Korea power systems.
28 August 2020 in IEEE Transactions on Power Systems
Reactive power reserves are important for grid stability and have a variety patterns depending on fault location as power systems become larger and complex. This paper presents the clustered effective reactive reserve (CEQR), an indicator that is suitable for identifying the risk of dynamic voltage stabitlity in terms of power system operation. This indicator provides the following features: i) It calculate the realistic reactive reserve to recognize dynamically changing system conditions; ii)it derive clustered areas to identify valid regions for system control. The proposed method uses the sensitivity between dynamic reactive resources or load buses and a particular bus to obtain the correlation. And since this indicator is calculated using only the system topology, current and maximum outputs of the generators, there is less computational burden. This study verified the features of clustered effective reactive reserve(CEQR) by analyzing the practicable dynamic voltage collapse scenarios in the Korean electric power(KEPCO) system. In addition, as a countermeasure against the dynamic voltage collapse, the control performance of blocking tap changer scheme using the proposed indicator is described.
This study analyzed the impact of varying the momentary cessation (MC) voltage level on the short circuit current of inverter-based resources (IBRs). To analyze the impact of the IBR MC function on the short circuit current, this paper proposes an advanced IBR model for fault current calculation to reflect its fault characteristics and a scheme for analyzing the influence of MC on the short circuit current. Based on the proposed methods, the authors conducted case studies using planning data from the Korea Electric Power Corporation (KEPCO). The influence of MC was investigated on the IBRs located at the southwest side of the KEPCO systems by screening the fault currents while varying the MC voltage. This paper demonstrates that the minimum MC voltage level needed for the fault current not to exceed the circuit breaker (CB) capacity can be proposed through analyzing the impact of MC voltage level on the short circuit current. The test results based on the proposed scheme showed that the short circuit current to power systems could not violate CB capacity if IBRs adjusted the MC voltage level higher than the lowest MC voltage level.
9 November 2025 in International Journal of Electrical Power & Energy Systems