Helge Averfalk

Mr. Helge Averfalk

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 April 2017 in Energies
Verified
Journal Article
Open access
PDF file
ADAndrei David
Andrei David
Brian Vad MathiesenBrian Vad Mathiesen
Brian Vad Mathiesen
HAHelge Averfalk
Helge Averfalk
SWSven Werner
Sven Werner
Henrik LundHenrik Lund
Henrik Lund
The Heat Roadmap Europe (HRE) studies estimated a potential increase of the district heating (DH) share to 50% of the entire heat demand by 2050, with approximately 25–30% of it being supplied using large-scale electric heat pumps. This study builds on this potential and aims to document that such developments can begin now with technologies currently available. We present a database and the status of the technology and its ability of expansion to other European locations by reviewing experiences aimed at further research or application in the heating industry. This is based on a survey of the existing capacity of electric large-scale heat pumps with more than 1 MW thermal output, operating in European DH systems. The survey is the first database of its kind containing the technical characteristics of these heat pumps, and provides the basis for the analysis of this paper. By quantifying the heat sources, refrigerants, efficiency and types of operation of 149 units with 1580 MW of thermal output, the study further uses this data to analyze if the deployment of this technology on a large-scale is possible in other locations in Europe. It finally demonstrates that the technical level of the existing heat pumps is mature enough to make them suitable for replication in other locations in Europe.

1 February 2020 in Energy
Verified
Journal Article
Open access
HAHelge Averfalk
Helge Averfalk
SWSven Werner
Sven Werner

30 October 2023 in Energy and Buildings
Verified
Journal Article
Open access
JLJohan Lind
Johan Lind
EMErik Möllerström
Erik Möllerström
HAHelge Averfalk
Helge Averfalk
FOFredric Ottermo
Fredric Ottermo

1 February 2018 in Energy
Verified
Journal Article
Open access
HAHelge Averfalk
Helge Averfalk
SWSven Werner
Sven Werner

13 April 2023 in Energy
Verified
Journal Article
Open access
LSLuis Sánchez-García
Luis Sánchez-García
HAHelge Averfalk
Helge Averfalk
EMErik Möllerström
Erik Möllerström
UPUrban Persson
Urban Persson

2 April 2019 in Energies
Verified
Journal Article
Open access
PDF file
HAHelge Averfalk
Helge Averfalk
FOFredric Ottermo
Fredric Ottermo
SWSven Werner
Sven Werner
This paper assesses pipe sizing aspects for previously proposed, novel, low heat distribution technology with three pipes. Assessment issues include heat loss, pressure loss, and pipe sizing for different typical pipe configurations. This assessment has been provided by the analysis of a case area with single-family houses. Concerning heat loss, the proposed three-pipe solutions have the same magnitude of heat loss as conventional twin pipes, since lower return temperatures compensate for the larger heat loss area from the third pipe. Regarding pressure loss, the main restriction on the size of the third pipe is limited to the pressure loss in the third pipe. Thermostatic valves to manage the flow rate of the third pipe are advocated, since alternative small pumps have not been found to be commercially available. The pipe sizing recommendation is that the third pipe for recirculation purposes can be two to three standard pipe sizes smaller than the corresponding supply and return pipe, if no prosumer is connected in the heat distribution network.