In this paper, we studied water transport under an unsteady flow regime in an experimental channel (4 m in length; 3 cm in width). Our experiments implicated some measuring requirements, specifically, a water level (WL) detection technique that is able to measure WL in a range of 2 cm with a precision of 1 mm. The existing WL detection techniques could not meet our measurement requirements. Therefore, we propose a new measurement method that combines two approaches: An “old” water contact technique (float) with a “new” remote non-contact technique (infrared sensor). We used an extruded polystyrene (XPS Foam) that needed some adequate treatment before using it as float in experimental measurements. The combination of IR-sensors with treated float foam lead to a sensitive measurement method that is able to detect flat and sharp flow signals, as well as highly dynamic variations of water surface level. Based on the experimental measurements of WL and outflow at the channel output, we deduced a loop rating curve that is suitable with a power law adjustment. The new measurement method could be extended to larger scale applications like rivers and more complicated cross section geometry of irregular shape.
The relationship between concentration and discharge (C/Q) is widely studied to understand the behavior of solute transport in complex natural media during storm events. The causes of C/Q hysteresis are due to the delay between the signals of C and Q at a given observation point. Many indices are used to characterize the C/Q hysteresis curve, like the hysteresis index (HI) and the flushing index (FI). The limitation of relating C/Q hysteresis relationships or indices to storm event parameters is because, in real-world situations, we ignore and do not control storm event parameters. This paper is the first attempt to study the variability of C/Q relationships under a well-known storm event on a controlled experimental channel. We tested nine scenarios where the storm event consisted of a triangular input signal with a constant peak and a variable duration. The main parameter of this study is the storm event duration. We calculated known indices, like the hysteresis index (HI) and the flushing index (FI), and we introduced the following two new indices: the saturation index (SI) and the bisector index (BI). Then we related all calculated indices to the storm duration parameter. The importance of our study is that it presents, for the first time, a quantitative description of how the magnitude of the hysteresis indices varies with the storm duration parameter. We found that the most popular HI index does not follow a monotonic behavior for increasing storm duration. Conversely, the FI index and the two newly introduced indices (SI and BI) follow a monotonic behavior for increasing storm duration according to a Fermi-type function. The SI varies between 0.11 and 0.93, while the BI varies between 1 and 0.32 for an increasing storm event duration.