Piotr W. Sielicki

Prof. Dr. Piotr W. Sielicki

Poznan University of Technology, Faculty of Civil and Environmental Engineering, Institute of Structural Engineering, M.Sklodowskiej-Curie 5, 60-965 Poznan, Poland
orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2019 in Engineering Failure Analysis
Verified
Journal Article
Closed access
PSPiotr W. Sielicki
Piotr W. Sielicki
TŁTomasz Łodygowski
Tomasz Łodygowski

3 January 2021 in Energies
Verified
Journal Article
Open access
PDF file
Hasan AL-RIFAIEHasan AL-RIFAIE
Hasan AL-RIFAIE
RSRobert Studziński
Robert Studziński
Tomasz GajewskiTomasz Gajewski
Tomasz Gajewski
MMMichał Malendowski
Michał Malendowski
Wojciech SumelkaWojciech Sumelka
Wojciech Sumelka
PSPiotr W. Sielicki
Piotr W. Sielicki
The need for more effective defence systems is of critical importance because of the rising risk of explosive attacks. Sandwich panels are used as plastically deforming sacrificial structures, absorbing blast wave energy. To the authors’ knowledge, the blast behaviour of sandwich panels with connected (welded/bolted/riveted) corrugated layers has been well covered in literature. Hence, the aim of this numerical study was to develop new, easy-to-build, non-expensive, graded sandwich panel with ‘unconnected’ corrugated layers that can be used as a multipurpose sacrificial protective structure against wide range of blast threats. The proposed sandwich panel is composed of six unconnected aluminium (AL6063-T4) core layers encased in a steel (Weldox 460E) frame with 330 × 330 × 150 mm overall dimensions. The numerical analysis was conducted using Abaqus/Explicit solver. First, the performance of four different nongraded layer topologies (trapezoidal, triangular, sinusoidal, and rectangular) was compared, when subjected to ~16 MPa peak reflected over-pressure (M = 0.5 kg of TNT at R = 0.5 m). Results showed that the trapezoidal topology outperformed other topologies, with uniform progressive collapse, lower reaction force, and higher plastic dissipation energy. Then, the trapezoidal topology was further analysed to design a ‘graded’ sandwich panel that can absorb a wide range of blast intensities (~4, 7, 11, 13, and 16 MPa peak reflected over-pressures) by using a (0.4, 0.8, 1.2 mm) stepwise thickness combination for the layers. In conclusion, the superior performance of the proposed sandwich panel with unconnected graded layers can be considered as a novel alternative to the conventional costly laser-welded sandwich panels. Applications of the new solution range from protecting civil structures to military facilities.

30 January 2020 in Shock Waves
Verified
Journal Article
Open access
PDF file
Tomasz GajewskiTomasz Gajewski
Tomasz Gajewski
PSPiotr W. Sielicki
Piotr W. Sielicki
The paper presents unique blast experiments in reference to scientific literature and official standards. Experimental scenarios reflect a hypothetical realistic combat situation of a human being covered from a blast wave behind a rigid building corner. In the scenario assumed, the overpressure loads affect the lungs while the person is standing or the eardrums while the person is kneeling at the aiming position. The paper presents 27 free-field experiments measuring the overpressure loads. All the measurements were taken behind the right angle of the rigid wall. Two masses of TNT were considered: 200 g and 400 g. In the selected cases, a low test-to-test variability of the measured data was observed. Detailed plots of overpressure versus time are presented for various distances behind the building corner and TNT charge masses. Peak overpressure versus positive impulse plots are also demonstrated. Furthermore, the safety thresholds regarding different locations behind the building corner are defined for the considered explosive masses.

1 December 2021 in International Journal of Impact Engineering
Verified
Journal Article
Open access
Wojciech SumelkaWojciech Sumelka
Wojciech Sumelka
MNMarcin Nowak
Marcin Nowak
ANAmr A. Nassr
Amr A. Nassr
Hasan AL-RIFAIEHasan AL-RIFAIE
Hasan AL-RIFAIE
MMMichał Malendowski
Michał Malendowski
PSPiotr W. Sielicki
Piotr W. Sielicki

17 April 2019 in Metals
Verified
Journal Article
Open access
PDF file
PSPiotr W. Sielicki
Piotr W. Sielicki
Wojciech SumelkaWojciech Sumelka
Wojciech Sumelka
TLTomasz Lodygowski
Tomasz Lodygowski
The research was based on data obtained from experimental studies and aims in the challenge of mapping these results by a mathematical (phenomenological) model. The field experiments were performed on an H-section steel column supported by a reinforced concrete foundation and subjected to a close-in explosion. Numerical studies were carried out using Abaqus/Explicit code. The user subroutine VUMAT for metallic obstacle was also implemented, together with a coupled Eulerian–Lagrangian approach. The steel column failure recorded during real field tests versus computational results was examined and compared. It was crucial that, from the computational point of view, the obstacle reflected the generalized thermo-elasto-viscoplastic (GTEV) behavior of Perzyna’s type, including an anisotropic measure of damage.

25 December 2020 in Materials
Verified
Journal Article
Open access
PDF file
RSRobert Studziński
Robert Studziński
Tomasz GajewskiTomasz Gajewski
Tomasz Gajewski
MMMichał Malendowski
Michał Malendowski
Wojciech SumelkaWojciech Sumelka
Wojciech Sumelka
Hasan AL-RIFAIEHasan AL-RIFAIE
Hasan AL-RIFAIE
PSPiotr W. Sielicki
Piotr W. Sielicki
In this paper, an experimental investigation is presented for sandwich panels with various core layer materials (polyisocyanurate foam, mineral wool, and expanded polystyrene) when subjected to a justified blast load. The field tests simulated the case for when 5 kg of trinitrotoluene (TNT) is localized outside a building’s facade with a 5150 mm stand-off distance. The size and distance of the blast load from the obstacle can be understood as the case of both accidental action and a real terroristic threat. The sandwich panels have a nominal thickness, with the core layer equal 100 mm and total exterior dimensions of 1180 mm × 3430 mm. Each sandwich panel was connected with two steel columns made of I140 PE section using three self-drilling fasteners per panel width, which is a standard number of fasteners suggested by the producers. The steel columns were attached to massive reinforced concrete blocks via wedge anchors. The conducted tests revealed that the weakest links of a single sandwich panel, subjected to a blast load, were both the fasteners and the strength of the core. Due to the shear failure of the fasteners, the integrity between the sandwich panel and the main structure is not provided. A comparison between the failure mechanisms for continuous (polyisocyanurate foam and expanded polystyrene) and non-continuous (mineral wool) core layer materials were conducted.