Pierfrancesco Franco

Prof. Pierfrancesco Franco

Department of Oncology, University of Turin
orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2010 in Lung Cancer
Verified
Journal Article
Closed access
URUmberto Ricardi
Umberto Ricardi
AFAndrea Riccardo Filippi
Andrea Riccardo Filippi
AGAlessia Guarneri
Alessia Guarneri
FGFrancesca Romana Giglioli
Francesca Romana Giglioli
PCPatrizia Ciammella
Patrizia Ciammella
RRRiccardo Ragona
Riccardo Ragona

1 December 2012 in Cancer Treatment Reviews
Verified
Journal Article
Closed access
ERElvio G. Russi
Elvio G. Russi
RCRenzo CORVO
Renzo CORVO
AMAnna Merlotti
Anna Merlotti
DADaniela Alterio
Daniela Alterio
Pierfrancesco FrancoPierfrancesco Franco
Pierfrancesco Franco
JBJacques Bernier
Jacques Bernier

29 December 2014 in Radiation Oncology
Verified
Journal Article
Open access
PDF file
AMAnna Merlotti
Anna Merlotti
DADaniela Alterio
Daniela Alterio
RVRiccardo Vigna-Taglianti
Riccardo Vigna-Taglianti
AMAlessandro Muraglia
Alessandro Muraglia
LLLuciana Lastrucci
Luciana Lastrucci
GSGiuseppe Sanguineti
Giuseppe Sanguineti
Performing intensity-modulated radiotherapy (IMRT) on head and neck cancer patients (HNCPs) requires robust training and experience. Thus, in 2011, the Head and Neck Cancer Working Group (HNCWG) of the Italian Association of Radiation Oncology (AIRO) organized a study group with the aim to run a literature review to outline clinical practice recommendations, to suggest technical solutions and to advise target volumes and doses selection for head and neck cancer IMRT. The main purpose was therefore to standardize the technical approach of radiation oncologists in this context. The following paper describes the results of this working group. Volumes, techniques/strategies and dosage were summarized for each head-and-neck site and subsite according to international guidelines or after reaching a consensus in case of weak literature evidence.

2 November 2012 in Radiation Oncology
Verified
Journal Article
Open access
PDF file
CFChristian Fiandra
Christian Fiandra
AFAndrea Riccardo Filippi
Andrea Riccardo Filippi
PCPaola Catuzzo
Paola Catuzzo
ABAngela Botticella
Angela Botticella
PCPatrizia Ciammella
Patrizia Ciammella
URUmberto Ricardi
Umberto Ricardi
Radiotherapy in Hodgkin’s Lymphoma (HL) is currently evolving with new attempts to further reduce radiation volumes to the involved-node concept (Involved Nodes Radiation Therapy, INRT) and with the use of intensity modulated radiotherapy (IMRT). Currently, IMRT can be planned and delivered with several techniques, and its role is not completely clear. We designed a planning study on a typical dataset drawn from clinical routine with the aim of comparing different IMRT solutions in terms of plan quality and treatment delivery efficiency. A total of 10 young female patients affected with early stage mediastinal HL and treated with 30 Gy INRT after ABVD-based chemotherapy were selected from our database. Five different treatment techniques were compared: 3D-CRT, VMAT (single arc), B-VMAT (“butterfly”, multiple arcs), Helical Tomotherapy (HT) and Tomodirect (TD). Beam energy was 6 MV, and all IMRT planning solutions were optimized by inverse planning with specific dose-volume constraints on OAR (breasts, lungs, thyroid gland, coronary ostia, heart). Dose-Volume Histograms (DVHs) and Conformity Number (CN) were calculated and then compared, both for target and OAR by a statistical analysis (Wilcoxon’s Test). PTV coverage was reached for all plans (V95% ≥ 95%); highest mean CN were obtained with HT (0.77) and VMAT (0.76). B-VMAT showed intermediate CN mean values (0.67), while the lowest CN were obtained with TD (0.30) and 3D-CRT techniques (0.30). A trend of inverse correlation between higher CN and larger healthy tissues volumes receiving low radiation doses was shown for lungs and breasts. For thyroid gland and heart/coronary ostia, HT, VMAT and B-VMAT techniques allowed a better sparing in terms of both Dmean and volumes receiving intermediate-high doses compared to 3D-CRT and TD. IMRT techniques showed superior target coverage and OAR sparing, with, as an expected consequence, larger volumes of healthy tissues (lungs, breasts) receiving low doses. Among the different IMRT techniques, HT and VMAT showed higher levels of conformation; B-VMAT and HT emerged as the planning solutions able to achieve the most balanced compromise between higher conformation around the target and smaller volumes of OAR exposed to lower doses (typical of 3D-CRT).

1 October 2020 in Clinical Ophthalmology
Verified
Journal Article
Open access
PDF file
RNRaffaele Nuzzi
Raffaele Nuzzi
MTMarta Trossarello
Marta Trossarello
SBSara Bartoncini
Sara Bartoncini
PMPaola Marolo
Paola Marolo
Pierfrancesco FrancoPierfrancesco Franco
Pierfrancesco Franco
URUmberto Ricardi
Umberto Ricardi
Aim of the Study: The study aims to quantify the incidence of ocular complications in patients irradiated on the head and neck area in our medical center, stratified by type of neoplasm and radiation dose received. Materials and Methods: From an existing database of patients radio-treated in our center, we selected 25 patients irradiated in the 2011– 2018 period. The patients had been treated for orbital lymphoma, nasopharyngeal carcinoma and cranial base meningioma. The selected patients received an ophthalmologic evaluation which included a complete ophthalmological and orthoptic assessment. Results: Our results showed a significantly higher incidence of DES (dry eye syndrome) and corneal complications for eyes receiving a Dmax higher than 40 Gy, as well as for cataract incidence in eyes that had received a Dmax to the lens higher than 5 Gy. We found an overall thinning of the RNFL (retinal nerve fiber layer) in eyes that had received a Dmax higher than 50 Gy, as well as a greater MD (mean deviation) from normal visual field values. Conclusion: In conclusion, we can say that the study confirms the presence of a correlation between the received radiation dose and the onset of eye complications, despite the small sample.

1 July 2021 in Critical Reviews in Oncology/Hematology
Verified
Journal Article
Closed access
HDHannah M. Dahn
Hannah M. Dahn
LBLiesbeth J. Boersma
Liesbeth J. Boersma
Dirk De RuysscherDirk De Ruysscher
Dirk De Ruysscher
IMIcro Meattini
Icro Meattini
BOBirgitte V. Offersen
Birgitte V. Offersen
OKOrit Kaidar-Person
Orit Kaidar-Person