Valentin Mateev

Prof. Valentin Mateev

Department of Electrical Apparatus, Technical University of Sofia, 1156 Sofia, Bulgaria
orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 June 2019 in Sensors
Verified
Journal Article
Open access
PDF file
Valentin MateevValentin Mateev
Valentin Mateev
Iliana MarinovaIliana Marinova
Iliana Marinova
ZKZhelyazko Kartunov
Zhelyazko Kartunov
Lithium-based batteries operation is related to some safety risks of dangerous flaming, integrity destruction, or even explosion. Gas leakage is an early and reliable indicator for such irreversible malfunctioning of electrical accumulators. Often, accurate gas emission source location sensing is difficult especially in heavy operational conditions, related to temperature changes, vibrations, movements, accelerations, etc. In this paper we propose a gas detection system, with catalytic type sensor array, and a numerical reconstruction method for precise gas emission source location inside the battery pack. The detection system employs a distributed array of CO sensors. Proposed sensor array configurations significantly reduce the number of sensing nodes inside the battery pack and fewer sensors than the protected battery elements are used. This way, data acquisition process by sensor nodes is also simplified. Several array configurations are considered according to their measurement efficiency and accuracy. Reconstruction algorithm is based on fast interpolation technique very suitable for real-time data processing. Estimation of reconstruction method accuracy is made by computational model of the gas diffusion inside the pack.

20 November 2019 in Electrical Engineering
Verified
Journal Article
Closed access
PDF file
Valentin MateevValentin Mateev
Valentin Mateev
Iliana MarinovaIliana Marinova
Iliana Marinova

14 June 2024 in Polymers
Verified
Journal Article
Open access
PDF file
Boriana R. TzanevaBoriana R. Tzaneva
Boriana R. Tzaneva
Valentin MateevValentin Mateev
Valentin Mateev
BSBozhidar Stefanov
Bozhidar Stefanov
Mariya AleksandrovaMariya Aleksandrova
Mariya Aleksandrova
Ivo Tsvetanov IlievIvo Tsvetanov Iliev
Ivo Tsvetanov Iliev
Herein, we investigate the potential application of a composite consisting of PEDOT:PSS/Graphene, deposited via spray coating on a flexible substrate, as an autonomous conducting film for applications in wearable biosensor devices. The stability of PEDOT:PSS/Graphene is assessed through electrochemical impedance spectroscopy (EIS), cyclic voltammetry (CV) and linear polarization (LP) during exposure to an artificial sweat electrolyte, while scanning electron microscopy (SEM) was employed to investigate the morphological changes in the layer following these. The results indicate that the layers exhibit predominant capacitive behavior in the potential range of −0.3 to 0.7 V vs. Ag/AgCl, with a cut-off frequency of approximately 1 kHz and retain 90% capacity after 500 cycles. Aging under exposure to air for 6 months leads only to a minor increase in impedance, demonstrating potential for storage under non-demanding conditions. However, prolonged exposure (>48 h) to the artificial sweat causes significant degradation, resulting in an impedance increase of over 1 order of magnitude. The observed degradation raises important considerations for the long-term viability of these layers in wearable biosensor applications, prompting the need for additional protective measures during prolonged use. These findings contribute to ongoing efforts to enhance the stability and reliability of conducting materials for biosensors in health care and biotechnology applications.

22 February 2023 in Energies
Verified
Journal Article
Open access
PDF file
GIGeorgi Ivanov Ivanov
Georgi Ivanov Ivanov
ASAnelia Spasova
Anelia Spasova
Valentin MateevValentin Mateev
Valentin Mateev
Iliana MarinovaIliana Marinova
Iliana Marinova
As a major component in electric power systems, power transformers are one of the most expensive and important pieces of electrical equipment. The trouble-free operation of power transformers is an important criterion for safety and stability in a power system. Technical diagnostics of electrical equipment are a mandatory part of preventing accidents and ensuring the continuity of the power supply. In this study, a complex diagnostic methodology was proposed and applied for special power transformers’ risk estimation. Twenty special power transformers were scored with the proposed risk estimation methodology. For each transformer, dissolved gas analysis (DGA) tests, transformer oil quality analysis, visual inspections of all current equipment on-site and historical data for the operation of each electrical research were conducted. All data were collected and analyzed under historical records of malfunctioning events. Statistical data for expected fault risk, based on long-term records, with such types of transformers were used to make more precise estimations of the current state of each machine and expected operational resource. The calculated degree of insulation polymerization was made via an ANN-assisted predictive method. Assessment of the collected data was applied to allow detailed information of the state of the power transformer to be rated. A method for risk assessment and reliability estimation was proposed and applied, based on the health index (HI) for each transformer.

15 August 2016
Verified
Conference Paper
Closed access
EMEmil Mechkov
Emil Mechkov
RTRaina Tzeneva
Raina Tzeneva
Valentin MateevValentin Mateev
Valentin Mateev
IYIvan Yatchev
Ivan Yatchev
The temperature distribution in the transformer interior is a significant parameter governing a transformer's performance and life expectancy. In the perspective of the user, temperatures in a transformer are important to determine the amount and duration of over load it can sustain, and to estimate the effects on the life of the transformer by operation at various temperatures. This paper presents the temperature field distribution modeling of oil-immersed distribution transformer 160kVA. Finite element method and ANSYS program have been employed for 3D model development. Based on this model, the thermal field distribution with values of temperature has been obtained.

20 December 2023 in Sensors
Verified
Journal Article
Open access
PDF file
Boriana R. TzanevaBoriana R. Tzaneva
Boriana R. Tzaneva
Mariya AleksandrovaMariya Aleksandrova
Mariya Aleksandrova
Valentin MateevValentin Mateev
Valentin Mateev
BSBozhidar Stefanov
Bozhidar Stefanov
Ivo Tsvetanov IlievIvo Tsvetanov Iliev
Ivo Tsvetanov Iliev
Electrodes based on PEDOT:PSS are gaining increasing importance as conductive electrodes and functional layers in various sensors and biosensors due to their easy processing and biocompatibility. This study investigates PEDOT:PSS/graphene layers deposited via spray coating on flexible PET substrates. The layers are characterized in terms of their morphology, roughness (via AFM and SEM), and electrochemical properties in artificial sweat using electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV). The layers exhibit dominant capacitive behavior at low frequencies, with cut-off frequencies determined for thicker layers at 1 kHz. The equivalent circuit used to fit the EIS data reveals a resistance of about three orders of magnitude higher inside the layer compared to the charge transfer resistance at the solid/liquid interface. The capacitance values determined from the CV curves range from 54.3 to 122.0 mF m−2. After 500 CV cycles in a potential window of 1 V (from −0.3 to 0.7 V), capacitance retention for most layers is around 94%, with minimal surface changes being observed in the layers. The results suggest practical applications for PEDOT:PSS/graphene layers, both for high-frequency impedance measurements related to the functioning of individual organs and systems, such as impedance electrocardiography, impedance plethysmography, and respiratory monitoring, and as capacitive electrodes in the low-frequency range, realized as layered PEDOT:PSS/graphene conductive structures for biosignal recording.