Gaetano Marenzi

Dr. Gaetano Marenzi


Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 July 2015 in BioMed Research International
Verified
Journal Article
Open access
PDF file
GMGaetano Marenzi
Gaetano Marenzi
Francesco RiccitielloFrancesco Riccitiello
Francesco Riccitiello
MTMariano Tia
Mariano Tia
ALAlessandro di Lauro
Alessandro di Lauro
GSGilberto Sammartino
Gilberto Sammartino
The aim of this study was to evaluate the effects of leukocyte- and platelet-rich fibrin (L-PRF) on the pain and soft tissue healing after tooth extractions. Twenty-six patients (9 males and 17 females) were treated with multiple extractions (2 to 8), with a total of 108 extractions. This was an exploratory single blinded randomized clinical trial with a split-mouth design. The pain after the surgery was assessed in each patient by the VAS scale (1 to 10) at intervals of 24-48-72-96 hours. The soft tissue healing was clinically evaluated at 3, 7, 14, and 21 days after surgery by the same examiner surgeon, using the modified Healing Index (4 to 12). The mean value of postextraction pain was 3.2 ± 0.3 in the experimental sides and 4.1 ± 0.1 in the control sides. After 7 days from the extractions, the values of modified Healing Index in the experimental and control groups were, respectively, 4.8 ± 0.6 and 5.1 ± 0.9. The use of L-PRF in postextraction sockets filling can be proposed as a useful procedure in order to manage the postoperative pain and to promote the soft tissue healing process, reducing the early adverse effects of the inflammation.

4 May 2021 in European Journal of Oral Sciences
Verified
Journal Article
Open access
PDF file
Cristiano ScandurraCristiano Scandurra
Cristiano Scandurra
Roberta GasparroRoberta Gasparro
Roberta Gasparro
PDPasquale - Dolce
Pasquale - Dolce
Vincenzo BochicchioVincenzo Bochicchio
Vincenzo Bochicchio
Benedetta MuziiBenedetta Muzii
Benedetta Muzii
NMNelson Mauro Maldonato
Nelson Mauro Maldonato
Dental anxiety is a crucial problem for dentistry because it may represent a significant risk to oral health. Different factors, whether non‐cognitive (e.g., traumatic dental events) or cognitive (e.g., the patient's subjective perceptions), may cause dental anxiety. However, previous studies have assessed these factors as independent predictors of dental anxiety, without providing any exploration of potential mediational pathways. The current study assessed the role of certain cognitive dimensions (i.e., the dentist's perceived professionalism and communicational attitudes, and the patient's perceived lack of control) as mediators between traumatic dental events and dental anxiety. The sample comprised 253 patients who had accessed a public university hospital dental surgery. The mediation analysis used a structural equation modeling. Traumatic dental events were positively associated with dental anxiety but, among the cognitive factors, only lack of control was. Furthermore, lack of control mediated the relationship between traumatic dental events and dental anxiety, although this mediation was only partial. This study sheds light on the mechanisms through which non‐cognitive and cognitive factors may affect dental anxiety. The clinical implications for dental practice, in terms of improving the psychological well‐being of patients, are discussed.

4 January 2016 in BioMed Research International
Verified
Journal Article
Open access
PDF file
GPGuerino Paoloantoni
Guerino Paoloantoni
GMGaetano Marenzi
Gaetano Marenzi
ABAndrea Blasi
Andrea Blasi
JMJolanda Mignogna
Jolanda Mignogna
GSGilberto Sammartino
Gilberto Sammartino
The purpose of this randomized controlled study is to investigate the clinical results obtained over four years and incidence of complications associated withone- versustwo-piece custom made zirconia anchorages, in single tooth implant-supported restorations of the maxillary anterior region. Sixty-five patients, with a total of 74 missing maxillary teeth, were selected in the period from February 2007 to July 2010. Two different ways of custom made zirconia abutment and final prosthetic restoration were evaluated: a standard zirconia abutment associated with a pressed layer of lithium disilicate with an all-ceramic cemented restoration versus one-piece restoration with the facing porcelain fired and pressed straight to the custom made zirconia abutment. In 29 cases, the restoration consisted of an all-ceramic restoration for cementation (two pieces); in 45 cases the restoration was a screw-retained restoration (one piece). Three all-ceramic restorations broke during the observation time. Two one-piece restorations fractured after 26 months. At follow-up examination there were no significant differences between one-piece and two-piece groups regarding the PI, BI, and MBL. Awaiting studies with longer follow-up times, a careful conclusion is that zirconia anchorages for single-implant restorations seem to demonstrate good short-term technical and biological results.

7 July 2023 in Prosthesis
Verified
Journal Article
Open access
PDF file
RIRoberta Iacono
Roberta Iacono
Yaniv MayerYaniv Mayer
Yaniv Mayer
GMGaetano Marenzi
Gaetano Marenzi
VBVitor Ferreira Balan
Vitor Ferreira Balan
EGEduardo Pires Godoy
Eduardo Pires Godoy
FBFrancesco Bagnasco
Francesco Bagnasco
Background: Dental implants have become the standard for replacing missing teeth. However, patients’ demands for shorter treatment times and the desire for aesthetics in their results can complicate the rehabilitation process, particularly when poor-quality bone is involved. In order to address these challenges, new methods of treating implant surfaces have been introduced. These methods aim to make the implants superhydrophilic and bioactive, enhancing their functionality and interactions with the surrounding tissues. Aim: The aim of the study was to retrospectively examine the efficacy of a superhydrophilic and bioactive implant for treatment of the edentulous maxillary anterior area. The study also aimed to evaluate whether this improved implant surface, by enhancing the osseointegration processes, could serve as a factor in speeding up the loading protocols. Materials and Methods: For this retrospective study, a total of 13 implants were included: 6 delayed restored implants and 7 immediately loaded implants placed in the anterior maxillary area. Clinical, radiographic, and esthetic outcomes were assessed. Baseline measurements of the insertion torque value (ITV) and stability implant quotient (ISQ) were recorded for all implants. In the early-loaded group, these measurements were also taken 30 days (t30) and 45 days (t45) after the placement of the implant to monitor their changes over time. Marginal bone loss (MBL) was calculated according to the changes in marginal bone level on intraoral X-rays taken at two different time points: at baseline and one year after loading. To evaluate the esthetic results, the pink esthetic score (PES) and the white esthetic score (WES) were assessed. For this evaluation, intraoral photographs were taken one year after implant loading. Results: A total of 7 implants were immediately restored, with a mean ITV of 32.29 ± 9.01 Ncm and a mean ISQ of 72.71 ± 2.81. These implants were placed in a bone environment with a mean density of 410.00 ± 194.42 HU. On the other hand, 6 implants with delayed loading had a mean ITV of 28.50 ± 3.27 Ncm, an ISQ of 67.92 ± 8.43, and a mean bone density of 607.50 ± 140.83 HU. The mean PES and WES after 1 year were, respectively, 8.71 ± 1.89 and 8.57 ± 0.79 for immediate and 8.33 ± 1.36 and 9.17 ± 1.33 for delayed-loaded implants. At 12 months after loading, the immediately loaded group had a MBL of 0.29 ± 0.29 mm, while the delayed-loaded group had a MBL of 0.33 ± 0.25. No statistically significant differences between the two treatment groups were found for any of the evaluated outcomes. Conclusions: Despite the limitations of this study, the obtained results may support the use of a superhydrophilic and bioactive implant surface for implant-prosthetic rehabilitation in critical loading protocols with satisfactory esthetic results.

6 June 2018 in BioMed Research International
Verified
Journal Article
Open access
PDF file
GMGaetano Marenzi
Gaetano Marenzi
JSJosè Camilla Sammartino
Josè Camilla Sammartino
GQGiuseppe Quaremba
Giuseppe Quaremba
VGVincenzo Graziano
Vincenzo Graziano
Andrea El HassaninAndrea El Hassanin
Andrea El Hassanin
VIVincenzo Iorio-Siciliano
Vincenzo Iorio-Siciliano
Background. Considerations about heat generation, wear, and corrosion due to some macrostructural bur components (e.g., cutting lips, rake angle, flute, and helix angle) have been widely reported. However, little is known about how the microstructural components of the implant drill surface can influence the implant drill lifetime and clinical performance. Aim. To investigate accurately the surface morphology of surgical bone drill, by means of multivariate and multidimensional statistical analysis, in order to assess roughness parameters able to predict the evolution of tribological phenomena linked to heat development, wear, and corrosion occurring in clinical use. Materials and Methods. The surfaces of implant drills approximately 2.0mm in diameter made by five manufacturers were examined by means of confocal microscope with white light laser interferometry, obtaining several surface roughness parameters. Statistical multivariate analysis based on discriminant analysis showed, for each cut-off, the parameters which discriminate the manufacturers. Results. The microstructural parameters used by discriminant analysis evidenced several differences in terms of drill surface roughness between the five manufacturers. Conclusions. The observed surface roughness difference of drills is able to predict a different durability and clinical performance especially in heat generation and wear onset.

20 July 2006
Verified
Journal Article
Closed access
Gilberto SammartinoGilberto Sammartino
Gilberto Sammartino
GMGaetano Marenzi
Gaetano Marenzi
LTLoredana Tammaro
Loredana Tammaro
ABA Bolognese
A Bolognese
ACA Calignano
A Calignano
VVV Vittoria
V Vittoria