The purpose of this systematic review was to investigate the clinical outcomes of frameworks made of different materials in patients with implant-supported full-arch prostheses. A literature search was conducted on MEDLINE, Scopus and Cochrane Library, until the 1st of March 2021, with the following search terms: framework or substructure combined with “dental implants”. The outcomes evaluated were: implant and prosthesis survival, bone resorption, biological and technical complications. The Cochrane Handbook for Systematic Reviews of Interventions was employed to assess the risk of bias in randomized clinical trials. The Newcastle–Ottawa quality assessment scale was used for non-randomized studies. In total, 924 records were evaluated for title and abstract, and 11 studies were included in the review: 4 clinical randomized trials and 7 cohort studies. The framework materials investigated were: gold alloy, titanium, silver-palladium alloy, zirconia and polymers including acrylic resin and carbon-fiber-reinforced composites. High implant and prosthetic cumulative survival rates were recorded by all included studies. Various materials and different fabrication techniques are now available as alternatives to traditional cast metal frameworks, for full-arch implant-supported rehabilitations. Further long-term studies are needed to validate the use of these materials and clarify their specific clinical indications and manufacturing protocols to optimize their clinical outcomes.
Oral squamous cell carcinoma (OSCC) is a widespread malignancy with high mortality. In particular, a delay in its diagnosis dramatically decreases the survival rate. The aim of this systematic review was to investigate and summarize clinical results in the literature, regarding the potential use of salivary microRNAs (miRNAs) as diagnostic and prognostic biomarkers for OSCC patients. Twelve papers were selected, including both case–control and cohort studies, and all of them detected significantly dysregulated miRNAs in OSCC patients compared to healthy controls. Based on our results, salivary miRNAs might provide a non-invasive and cost-effective method in the diagnosis of OSCC, and also to monitor more easily its evolution and therapeutic response and therefore aid in the establishment of specific therapeutic strategies.
Background: Ultraviolet (UV) and non-thermal plasma functionalization are surface treatment modalities that seem able to improve osseointegration. The aim of this systematic review and meta-analysis is to assess the effect of the two methods and possible differences. Materials and Methods: The systematic research of pre-clinical animal studies was conducted up to May 2020 in the databases PubMed/Medline, Scopus and the Cochrane Lybrary. A meta-analysis was performed by using the DerSimonian–Laird estimator in random-effects models. Results: Through the digital search, 518 articles were identified; after duplicate removal and screening process 10 papers were included. Four studies evaluating UV treatment in rabbits were included in the meta-analysis. The qualitative evaluation of the included studies showed that both UV photofunctionalization and non-thermal plasma argon functionalization of titanium implant surfaces might be effective in vivo to improve the osseointegration. The meta-analysis on four studies evaluating UV treatment in rabbits showed that bone to implant contact values (expressed as standardized mean differences and raw mean differences) were significantly increased in the bio-activated groups when follow-up times were relatively homogeneous, although a high heterogeneity (I2 > 75%) was found in all models. Conclusions: The present systematic review and meta-analysis on pre-clinical studies demonstrated that chair-side treatment of implants with UV or non-thermal plasma appear to be effective for improving osseointegration. This systematic review supports further clinical trials on this topic.
(1) Background: Intraoral scanners (IOS) are widely used in prosthodontics. However, a good trueness is mandatory to achieve optimal clinical results. The aim of the present in vitro study was to compare two IOS considering the operator’s experience and different implant clinical scenarios. (2) Methods: Two IOS (IT—Itero, Align Technology; and OP—Opera MC, Opera System, Monaco) were compared simulating three different clinical scenarios: single implant, two implants, and full-arch rehabilitation. Ten scans were taken for each configuration by two different operators (one expert, one inexperienced); influence of operator experience and the type of scanner used was investigated. (3) Results: Trueness of the scans differed between the experienced and non-experienced operator and this difference was statistically significant in all the three scenarios (p = 0.000–0.001, 0.037). A significant difference was present between the scanners (p = 0.000), in the two-implant and full-arch scenarios (p = 0.00). (4) Conclusions: Experience of the operator significantly affect trueness of IT and OP scanners. A statistically significant difference was present among IOS in the two-implant and full-arch scenarios.
Background: The aim of the present study was to investigate the accuracy of a new digital impression system, comparing it to the plaster impression technique in the realization of full-arch implant-supported metal frameworks. Methods: We took 11 scans (8 of the upper maxilla and 3 of the lower jaw) on a sample of nine patients previously rehabilitated with fixed full-arch screw-retained prostheses following the Columbus Bridge Protocol (CBP) with four to six implants (total: 51) since at least 4 months. Two impressions were taken for each dental arch: one analogic plaster impression using pick-up copings and an open tray technique and a second one using an intra-oral scanner. Two milled metal substructures were realised. The precision and passivity of the substructures were clinically analysed through the Sheffield test and endo-oral radiographs. Laboratory scans of the plaster casts obtained from an intra-oral scanner (IOS) and of the plaster casts obtained from traditional impression were compared with the intraoral scans following Hausdorff’s method and an industrial digital method of optical detection to measure discrepancies. A Mann–Whitney test was performed in order to investigate average distances between surfaces after the superposition. Results: The Sheffield test demonstrated an excellent passivity of the frameworks obtained through both the digital and the analogic method. In 81.81% of cases (n = 9) both substructures were found to have a perfect fit with excellent passivity, while in 18.18% (n = 2) of cases the substructures were found to have a very slight discrepancy. From the radiographic examination, no gaps between the frameworks and the implant heads or multiunit abutments were observed, with 100% accuracy. By superimposing digital files of scans according to Hausdorff’s method, a statistically significant discrepancy (p = 0.006) was found between the digital scans and the digital models obtained from plaster impressions. Three-dimensional optical detection found a mean discrepancy of 0.11 mm between the analogic cast and the cast derived from the digital impression. Conclusions: The present study clinically demonstrates that milled implant-supported full-arch frameworks obtained through a digital scan and the herein described technique have an accuracy comparable to those obtained with traditional plaster impression.
Background: Dental implants have become the standard for replacing missing teeth. However, patients’ demands for shorter treatment times and the desire for aesthetics in their results can complicate the rehabilitation process, particularly when poor-quality bone is involved. In order to address these challenges, new methods of treating implant surfaces have been introduced. These methods aim to make the implants superhydrophilic and bioactive, enhancing their functionality and interactions with the surrounding tissues. Aim: The aim of the study was to retrospectively examine the efficacy of a superhydrophilic and bioactive implant for treatment of the edentulous maxillary anterior area. The study also aimed to evaluate whether this improved implant surface, by enhancing the osseointegration processes, could serve as a factor in speeding up the loading protocols. Materials and Methods: For this retrospective study, a total of 13 implants were included: 6 delayed restored implants and 7 immediately loaded implants placed in the anterior maxillary area. Clinical, radiographic, and esthetic outcomes were assessed. Baseline measurements of the insertion torque value (ITV) and stability implant quotient (ISQ) were recorded for all implants. In the early-loaded group, these measurements were also taken 30 days (t30) and 45 days (t45) after the placement of the implant to monitor their changes over time. Marginal bone loss (MBL) was calculated according to the changes in marginal bone level on intraoral X-rays taken at two different time points: at baseline and one year after loading. To evaluate the esthetic results, the pink esthetic score (PES) and the white esthetic score (WES) were assessed. For this evaluation, intraoral photographs were taken one year after implant loading. Results: A total of 7 implants were immediately restored, with a mean ITV of 32.29 ± 9.01 Ncm and a mean ISQ of 72.71 ± 2.81. These implants were placed in a bone environment with a mean density of 410.00 ± 194.42 HU. On the other hand, 6 implants with delayed loading had a mean ITV of 28.50 ± 3.27 Ncm, an ISQ of 67.92 ± 8.43, and a mean bone density of 607.50 ± 140.83 HU. The mean PES and WES after 1 year were, respectively, 8.71 ± 1.89 and 8.57 ± 0.79 for immediate and 8.33 ± 1.36 and 9.17 ± 1.33 for delayed-loaded implants. At 12 months after loading, the immediately loaded group had a MBL of 0.29 ± 0.29 mm, while the delayed-loaded group had a MBL of 0.33 ± 0.25. No statistically significant differences between the two treatment groups were found for any of the evaluated outcomes. Conclusions: Despite the limitations of this study, the obtained results may support the use of a superhydrophilic and bioactive implant surface for implant-prosthetic rehabilitation in critical loading protocols with satisfactory esthetic results.