Advanced in situ techniques based on electrons and X-rays are increasingly used to gain insights into fundamental processes in liquids. However, probing liquid samples with ionizing radiation changes the solution chemistry under observation. In this work, we show that a radiation-induced decrease in pH does not necessarily correlate to an increase in acidity of aqueous solutions. Thus, pH does not capture the acidity under irradiation. Using kinetic modeling of radiation chemistry, we introduce alternative measures of acidity (radiolytic acidity π* and radiolytic ion product KW*), that account for radiation-induced alterations of both H+ and OH- concentration. Moreover, we demonstrate that adding pH-neutral solutes such as LiCl, LiBr, or LiNO3 can trigger a significant change in π*. This provides a huge parameter space to tailor the acidity for in situ experiments involving ionizing radiation, as present in synchrotron facilities or during liquid-phase electron microscopy.
Utilizing ionizing radiation for in situ studies in liquid media enables unique insights into nanostructure formation dynamics. As radiolysis interferes with observations, kinetic simulations are employed to understand and exploit beam‐liquid interactions. By introducing an intuitive tool to simulate arbitrary kinetic models for radiation chemistry, it is demonstrated that these models provide a holistic understanding of reaction mechanisms. This is shown for irradiated HAuCl4 solutions allowing for quantitative prediction and tailoring of redox processes in liquid‐phase transmission electron microscopy (LP‐TEM). Moreover, it is demonstrated that kinetic modeling of radiation chemistry is applicable to investigations utilizing X‐rays such as X‐ray diffraction (XRD). This emphasizes that beam‐sample interactions must be considered during XRD in liquid media and shows that reaction kinetics do not provide a threshold dose rate for gold nucleation relevant to LP‐TEM and XRD. Furthermore, it is unveiled that oxidative etching of gold nanoparticles depends on both, precursor concentration, and dose rate. This dependency is exploited to probe the electron beam‐induced shift in Gibbs free energy landscape by analyzing critical radii of gold nanoparticles.
Analysis of sweat chloride levels in cystic fibrosis (CF) patients is essential not only for diagnosis but also for the monitoring of therapeutic responses to new drugs, such as cystic fibrosis transmembrane conductance regulator (CFTR) modulators and potentiators. Using iontophoresis as the gold standard can cause complications like burns, is uncomfortable, and requires repetitive hospital visits, which can be particularly problematic during a pandemic, where distancing and hygiene requirements are increased; therefore, it is necessary to develop fast and simple measures for the diagnosis and monitoring of CF. A screen-printed, low-cost chloride sensor was developed to remotely monitor CF patients. Using potentiometric measurements, the performance of the sensor was tested. It showed good sensitivity and a detection limit of 2.7 × 10−5 mol/L, which covered more than the complete concentration range of interest for CF diagnosis. Due to its fast response of 30 s, it competes well with standard sensor systems. It also offers significantly reduced costs and can be used as a portable device. The analysis of real sweat samples from healthy subjects, as well as CF patients, demonstrates a proper distinction using the screen-printed sensor. This approach presents an attractive remote measurement alternative for fast, simple, and low-cost CF diagnosis and monitoring
In situ TEM utilizing windowed gas cells is a promising technique for studying catalytic processes, wherein temperature is one of the most important parameters to be controlled. Current gas cells are only capable of temperature measurement on a global (mm) scale, although the local temperature at the spot of observation (µm to nm scale) may significantly differ. Thus, local temperature fluctuations caused by gas flow and heat dissipation dynamics remain undetected when solely relying on the global device feedback. In this study, we overcome this limitation by measuring the specimen temperature in situ utilizing parallel-beam electron diffraction at gold nanoparticles. By combining this technique with an advanced data processing algorithm, we achieve sub-Kelvin precision in both, vacuum as well as gaseous environments. Mitigating charging effects is furthermore shown to minimize systematic errors. By utilizing this method, we characterize the local thermal stability of a state-of-the-art gas cell equipped with heating capability in vacuum and under various gas-flow conditions. Our findings provide crucial reference for in situ investigations into catalysis.
Indium gallium zinc oxide (IGZO)-based ferroelectric thin-film transistors (FeTFTs) are being vigorously investigated for being deployed in computing-in-memory (CIM) applications. Content-addressable memories (CAMs) are the quintessential example of CIM, which conduct a parallel search over a queue or stack to obtain the matched entries for a given input data. CAM cells offer the ability for massively parallel searches in a single clock cycle throughout an entire CAM array for the input query, thereby enabling pattern matching and searching functionality. Therefore, CAM cells are used extensively for pattern matching or search operations in data-centric computing. This paper investigates the impact of retention degradation on IGZO-based FeTFT on the multibit operation in content CAM cell applications. We propose a scalable multibit 1FeTFT-1T-based CAM cell composed of only one FeTFT and one transistor, thus significantly improving the density and energy efficiency compared with conventional complementary metal-oxide-semiconductor (CMOS)-based CAM. We successfully demonstrate the operations of our proposed CAM with storage and search by exploiting the multilevel states of the experimentally calibrated IGZO-based FeTFT devices. We also investigate the impact of retention degradation on the search operation. Our proposed IGZO-based 3-bit and 2-bit CAM cell shows 104 s and 106 s retention, respectively. The single-bit CAM cell shows lifelong (10 years) retention.