Chen-Hua Yeow

Dr. Chen-Hua Yeow

National University Hospital, National University of Singapore, Singapore, Singapore
orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2016 in Soft Robotics
Verified
Journal Article
Closed access
HYHong Kai Yap
Hong Kai Yap
HNHui Yong Ng
Hui Yong Ng
CYChen-Hua Yeow
Chen-Hua Yeow
This work presents a novel technique for direct 3D printing of soft pneumatic actuators using 3D printers based on fused deposition modeling (FDM) technology. Existing fabrication techniques for soft pneumatic actuators with complex inner geometry are normally time-consuming and involve multistep processes. A low-cost open-source consumer 3D printer and a commercially available printing material were identified for printing soft pneumatic actuators with complex inner geometry and high degree of freedom. We investigated the material properties of the printing material, simulated the mechanical behavior of the printed actuators, characterized the performances of the actuators in terms of their bending capability, output forces, as well as durability, and demonstrated the potential soft robotic applications of the 3D printed actuators. Using the 3D printed actuators, we developed a soft gripper that was able to grasp and lift heavy objects with high pay–-to-weight ratio, which demonstrated that the actuators were able to apply high forces. To demonstrate the ability of the actuators to achieve complex movements, such as bidirectional bending movements, we also developed wearable hand and wrist exoskeletons that were able to assist finger flexion and wrist flexion–extension. The proposed technique is the first-in-class approach to directly 3D print airtight soft pneumatic actuators for soft robotic applications using FDM technology.

15 February 2017 in IEEE Robotics and Automation Letters
Verified
Journal Article
Closed access
HYHong Kai Yap
Hong Kai Yap
PKPhone May Khin
Phone May Khin
TKTze Hui Koh
Tze Hui Koh
YSYi Sun
Yi Sun
XLXinquan Liang
Xinquan Liang
CYChen-Hua Yeow
Chen-Hua Yeow
This letter presents a fully fabric-based bidirectional soft robotic glove designed to assist hand impaired patients in rehabilitation exercises and performing activities of daily living. The glove provides both active finger flexion and extension for hand assistance and rehabilitative training, through its embedded fabric-based actuators that are fabricated by heat press and ultrasonic welding of flexible thermoplastic polyurethane-coated fabrics. Compared to previous developed elastomeric-based actuators, the actuators are able to achieve smaller bend radius and generate sufficient force and torque to assist in both finger flexion and extension at lower air pressure. In this letter, experiments were conducted to characterize the performances of the glove in terms of its kinematic and grip strength assistances on five healthy participants. Additionally, we present a graphical-user interface that allows user to choose the desired rehabilitation exercises and control modes, which include button-controlled-assistive mode, cyclic movement training, intention-driven task-specific training, and bilateral rehabilitation training.

6 May 2016 in Advanced Materials Technologies
Verified
Journal Article
Closed access
PDF file
JYJoo Chuan Yeo
Joo Chuan Yeo
HYHong Kai Yap
Hong Kai Yap
WXWang Xi
Wang Xi
ZWZhiping Wang
Zhiping Wang
CYChen-Hua Yeow
Chen-Hua Yeow
CLChwee Teck Lim
Chwee Teck Lim

1 May 2015
Verified
Conference Paper
Closed access
HYHong Kai Yap
Hong Kai Yap
JLJeong Hoon Lim
Jeong Hoon Lim
FNFatima Nasrallah
Fatima Nasrallah
JGJames C. H. Goh
James C. H. Goh
CYChen-Hua Yeow
Chen-Hua Yeow
In this paper, we present the design of a soft wearable exoskeleton that comprises of a glove embedded with pneumatic actuators of variable stiffness for hand assistive and rehabilitation application. The device is lightweight and easily wearable due to the usage of soft pneumatic actuators. A key feature of the device is the variable stiffness of the actuators at different localities that not only conform to the finger profile during actuation, but also provides customizability for different hand dimensions. The actuators can achieve different bending profiles with variable stiffness implemented at different localities. Therefore, the device is able to perform different hand therapy exercises such as full fist, straight fist, hook fist and table top. The device was characterized in terms of its range of motion and maximum force output. Experiments were conducted to examine the differences between active and passive actuation. The results showed that the device could achieve hand grasping and pinching with acceptable range of motion and force.

1 September 2010 in Biomaterials
Verified
Journal Article
Closed access
WTWei Seong Toh
Wei Seong Toh
ELEng Hin Lee
Eng Hin Lee
XGXi-Min Guo
Xi-Min Guo
JCJerry K.Y. Chan
Jerry K.Y. Chan
CYChen-Hua Yeow
Chen-Hua Yeow
YCYing Chen
Ying Chen

2 April 2020 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
NCNicholas Cheng
Nicholas Cheng
KPKok Soon Phua
Kok Soon Phua
HLHwa Sen Lai
Hwa Sen Lai
PTPui Kit Tam
Pui Kit Tam
KTKa Yin Tang
Ka Yin Tang
JLJEONG HOON LIM
JEONG HOON LIM
Objective: This randomized controlled feasibility study investigates the ability for clinical application of the Brain-Computer Interface-based Soft Robotic Glove (BCI-SRG) incorporating activities of daily living (ADL)-oriented tasks for stroke rehabilitation. Methods: Eleven recruited chronic stroke patients were randomized into BCI-SRG or Soft Robotic Glove (SRG) group. Each group underwent 120-minute intervention per session comprising 30-minute standard arm therapy and 90-minute experimental therapy (BCI-SRG or SRG). To perform ADL tasks, BCI-SRG group used motor imagery-BCI and SRG, while SRG group used SRG without motor imagery-BCI. Both groups received 18 sessions of intervention over 6 weeks. Fugl-Meyer Motor Assessment (FMA) and Action Research Arm Test (ARAT) scores were measured at baseline (week 0), post- intervention (week 6), and follow-ups (week 12 and 24). In total, 10/11 patients completed the study with 5 in each group and 1 dropped out. Results: Though there were no significant intergroup differences for FMA and ARAT during 6-week intervention, the improvement of FMA and ARAT seemed to sustain beyond 6-week intervention for BCI-SRG group, as compared with SRG control. Incidentally, all BCI-SRG subjects reported a sense of vivid movement of the stroke-impaired upper limb and 3/5 had this phenomenon persisting beyond intervention while none of SRG did. Conclusion: BCI-SRG suggested probable trends of sustained functional improvements with peculiar kinesthetic experience outlasting active intervention in chronic stroke despite the dire need for large-scale investigations to verify statistical significance. Significance: Addition of BCI to soft robotic training for ADL-oriented stroke rehabilitation holds promise for sustained improvements as well as elicited perception of motor movements.