Ramya Selvaraj

Ms. Ramya Selvaraj

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 May 2020 in Molecules
Verified
Journal Article
Open access
PDF file
RSRamya Selvaraj
Ramya Selvaraj
NVNilesh J Vasa
Nilesh J Vasa
SMShiva Nagendra S M
Shiva Nagendra S M
BMBoris Mizaikoff
Boris Mizaikoff
Human exhaled breath consists of more than 3000 volatile organic compounds, many of which are relevant biomarkers for various diseases. Although gas chromatography has been the gold standard for volatile organic compound (VOC) detection in exhaled breath, recent developments in mid-infrared (MIR) laser spectroscopy have led to the promise of compact point-of-care (POC) optical instruments enabling even single breath diagnostics. In this review, we discuss the evolution of MIR sensing technologies with a special focus on photoacoustic spectroscopy, and its application in exhaled breath biomarker detection. While mid-infrared point-of-care instrumentation promises high sensitivity and inherent molecular selectivity, the lack of standardization of the various techniques has to be overcome for translating these techniques into more widespread real-time clinical use.

24 October 2019 in Analytical Chemistry
Verified
Journal Article
Closed access
RSRamya Selvaraj
Ramya Selvaraj
NVNilesh Jayantilal Vasa
Nilesh Jayantilal Vasa
SNS. M. Shiva Nagendra
S. M. Shiva Nagendra

1 October 2017 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
RSRamya Selvaraj
Ramya Selvaraj
AKAbdul Nasir K.T.
Abdul Nasir K.T.
NVNilesh J. Vasa
Nilesh J. Vasa
SSShiva Nagendra S.M.
Shiva Nagendra S.M.

20 May 2019 in Applied Optics
Verified
Journal Article
Closed access
PDF file
RSRamya Selvaraj
Ramya Selvaraj
NVNilesh J Vasa
Nilesh J Vasa
SNS. M. Shiva Nagendra
S. M. Shiva Nagendra
The broadband photoacoustic spectroscopy (PAS) technique is proposed and demonstrated for measurement of CH4, CO2, and H2O vapor in the 1.6 to 2.0 μm wavelength region. The wide spectrum of a supercontinuum light source is used to cover broadband absorption bands of multiple gas species. This sensor works in the off-resonant frequency of the designed photoacoustic cell and exhibits a wide concentration measurement range of parts per billion by volume (ppb-v) to 100%. The PAS sensor is further tested in real time by measuring the concentration of CO2, CH4, and H2O vapor in biogas plants.

1 January 2019
Verified
Conference Paper
Closed access
PDF file
RSRamya Selvaraj
Ramya Selvaraj
NVNilesh J Vasa
Nilesh J Vasa
SMShiva Nagendra S M
Shiva Nagendra S M
Online measurement of CO2, CH4 and H2O in a biogas plant using a Supercontinuum laser based off-resonant broadband photoacoustic spectroscopy is realized. The system exhibits a wide dynamic range from ppbv - 100% concentration.

12 July 2024 in IEEE Sensors Letters
Verified
Journal Article
Closed access
SKSaran Kumar K
Saran Kumar K
SSSooraj Shiby
Sooraj Shiby
RSRamya Selvaraj
Ramya Selvaraj
SSSatyanaryanan Seshadri
Satyanaryanan Seshadri
SNS M Shiva Nagendra
S M Shiva Nagendra
NVNilesh J Vasa
Nilesh J Vasa
A hollow-core fiber (HCF) combined with a broadband supercontinuum laser-based direct absorption spectroscopy technique is pro- posed and demonstrated for concentration measurements of gas mixtu- res. A dual-wavelength technique is used to eliminate gas interference in multigas sensing. The concentrations of methane (CH 4 ) in two bands, 1.6 and 2.3 µm, ammonia (NH 3 ) in two bands, 2 and 2.3 µm, and carbon dioxide (CO 2 ) in the 2-µm band are measured. The measurements were performed using 0.5, 1, 5, and 10 m long HCF covering multiple absorption lines in the given band. The minimum detection limit (MDL) is improved as the signal-to-noise ratio was enhanced up to 3.9 dB by considering cumulative absorbance obtained from multiple absorption lines in the broadband measurement. The MDL were 13 and 15 parts-per-million (ppm) for CH 4 at 1.6 and 2.3 µm, respectively; 13 and 17 ppm for NH 3 at 2 and 2.3 µm, respectively; and 154 ppm for CO 2 at 2 µm band. The proposed dual-wavelength measurement technique was further extended to measure concentrations of gases in biogas samples. CH 4 , CO 2 , and hydrogen sulfide were measured to be 54.7%, 46.1%, and 2.1%, respectively, and atmospheric CO 2 of 421 ppm was also measured using a 10-m long HCF. The system offers excellent long-term stability for over continuous measurement of 4 h.