Aranka Ilea

Prof. Dr. Aranka Ilea

Department of Oral Rehabilitation, Faculty of Dentistry, Iuliu Hațieganu University of Medicine and Pharmacy, Cluj-Napoca, Romania
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 February 2019 in Biosensors
Verified
Journal Article
Open access
PDF file
Aranka IleaAranka Ilea
Aranka Ilea
VAVlad Andrei
Vlad Andrei
CFClaudia Nicoleta Feurdean
Claudia Nicoleta Feurdean
Anida BăbțanAnida Băbțan
Anida Băbțan
Bianca-Nausica PetrescuBianca-Nausica Petrescu
Bianca-Nausica Petrescu
Cecilia CristeaCecilia Cristea
Cecilia Cristea
Background: Saliva has been recently proposed as an alternative to classic biofluid analyses due to both availability and reliability regarding the evaluation of various biomarkers. Biosensors have been designed for the assessment of a wide spectrum of compounds, aiding in the screening, diagnosis, and monitoring of pathologies and treatment efficiency. This literature review aims to present the development in the biosensors research and their utility using salivary assessment. Methods: a comprehensive literature search has been conducted in the PubMed database, using the keywords “saliva” and “sensor”. A two-step paper selection algorithm was devised and applied. Results: The 49 papers selected for the present review focused on assessing the salivary biomarkers used in general diseases, oral pathologies, and pharmacology. The biosensors proved to be reliable tools for measuring the salivary levels of biochemical metabolic compounds such as glucose, proteinases and proteins, heavy metals and various chemical compounds, microorganisms, oncology markers, drugs, and neurotransmitters. Conclusions: Saliva is a biofluid with a significant clinical applicability for the evaluation and monitoring of a patient’s general health. Biosensors designed for assessing a wide range of salivary biomarkers are emerging as promising diagnostic or screening tools for improving the patients’ quality of life.

24 March 2020 in Materials
Verified
Journal Article
Open access
PDF file
IMIoana Codruta Mirica
Ioana Codruta Mirica
Gabriel FurtosGabriel Furtos
Gabriel Furtos
BBBogdan Bâldea
Bogdan Bâldea
Ondine LucaciuOndine Lucaciu
Ondine Lucaciu
Aranka IleaAranka Ilea
Aranka Ilea
RCRadu Septimiu Campian
Radu Septimiu Campian
The aim of this study was to evaluate the correlation between the percent of inorganic filler by weight (wt. %) and by volume (vol. %) of 11 flowable resin composites (FRCs) and their mechanical properties. To establish the correlation, the quantity of inorganic filler was determined by combustion and shape/size analyzed by SEM images. The compressive strength (CS), flexural strength (FS), and flexural modulus (FM) were determined. The CS values were between 182.87-310.38 MPa, the FS values ranged between 59.59 and 96.95 MPa, and the FM values were between 2.34 and 6.23 GPa. The percentage of inorganic filler registered values situated between 52.25 and 69.64 wt. % and 35.35 and 53.50 vol. %. There was a very good correlation between CS, FS, and FM vs. the inorganic filler by wt. % and vol. %. (R2 = 0.8899–0.9483). The highest regression was obtained for the FM values vs. vol. %. SEM images of the tested FRCs showed hybrid inorganic filler for Filtek Supreme XT (A3) and StarFlow (A2) and a homogeneous type of inorganic filler for the other investigated materials. All of the FS values were above 50 MPa, the ISO 4049/2019 limit for FRCs.

12 March 2022 in Materials
Verified
Journal Article
Open access
PDF file
NFNoémi Farkas
Noémi Farkas
LMLaura Marincaș
Laura Marincaș
RBRéka Barabás
Réka Barabás
Liliana BIZOLiliana BIZO
Liliana BIZO
Aranka IleaAranka Ilea
Aranka Ilea
Lucian Barbu-TudoranLucian Barbu-Tudoran
Lucian Barbu-Tudoran
The present study aimed to prepare nanofibers by electrospinning in the system polylactic acid-hydroxyapatite-doxycycline (PLA-HAP-Doxy) to be used as a drug delivery vehicle. Two different routes were employed for the preparation of Doxy-containing nanofibers: Immobilization on the electrospun mat’s surface and encapsulation in the fiber structure. The nanofibers obtained by Doxy encapsulation were characterized using Fourier transform infrared (FTIR) spectroscopy, thermogravimetric (TG) and differential thermal analyses (DTA) and scanning electron microscopy (SEM). The adsorption properties of pure PLA and PLA-HAP nanofibers were investigated for solutions with different Doxy concentrations (3, 7 and 12 wt%). Moreover, the desorption properties of the active substance were tested in two different fluids, simulated body fluid (SBF) and phosphate buffer solution (PBS), to evidence the drug release properties. In vitro drug release studies were performed and different drug release kinetics were assessed to confirm the use of these nanofiber materials as efficient drug delivery vehicles. The obtained results indicate that the PLA-HAP-Doxy is a promising system for biomedical applications, the samples with 3 and 7 wt% of Doxy-loaded PLA-HAP nanofibers prepared by physical adsorption are the most acceptable membranes to provide prolonged release in PBS/SBF rather than an immediate release of Doxy.

1 September 2018 in Archives of Oral Biology
Verified
Journal Article
Closed access
Aranka IleaAranka Ilea
Aranka Ilea
Anida BăbțanAnida Băbțan
Anida Băbțan
ABAdina Bianca Boșca
Adina Bianca Boșca
MCMaria Crişan
Maria Crişan
Bianca-Nausica PetrescuBianca-Nausica Petrescu
Bianca-Nausica Petrescu
RCRadu Septimiu Câmpian
Radu Septimiu Câmpian

5 October 2019 in Cranio®
Verified
Journal Article
Closed access
Aranka IleaAranka Ilea
Aranka Ilea
DTDaniela Timuș
Daniela Timuș
JHJulian Höpken
Julian Höpken
VAVlad Andrei
Vlad Andrei
ABAnida-Maria Băbțan
Anida-Maria Băbțan
Anca Stefania MesarosAnca Stefania Mesaros
Anca Stefania Mesaros
Objective: Oral appliance therapy is a non-invasive treatment that offers a wide variety of oral devices for the treatment of obstructive sleep apnea (OSA). The present review focuses on the effectiveness of mandibular advancement devices for the treatment of OSA. Methods: A systematic review based on the PRISMA checklist was carried out. A detailed electronic database search was conducted using “Obstructive sleep apnea” AND “Oral appliance” AND “Dentistry” as keywords. Results: The initial search in the electronic databases resulted in a total of 262 papers. After the title and abstract analysis and full-text review, the number of eligible papers was reduced to 15. Conclusion: The mandibular advancement device is an effective treatment, improving the Apnea Hypopnea Index and the symptoms of patients with OSA in 92% of the subjects from all the investigated studies. The future may include the integration of a biosensor for the diagnosis and follow-up. Abbreviations: OSA: Obstructive sleep apnea; MADs: Mandibular advancement devices; CPAP: Continuous positive airway pressure; OAT: Oral appliance therapy; MRD: Mandibular repositioning devices; MAS: Mandibular advancement splints; MAA: Mandibular advancement appliances; OA: Oral appliances; AASM: American Academy of Sleep Medicine; AHI: Apnea-hypopnea index; EEG: Sleep-related breathing disorder SRBD; Electroencephalogram; EOG: Electrooculogram; ECG: Electrocardiogram; QOL: Quality of life; TMJ: Temporomandibular joint.

28 September 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Anca BeczeAnca Becze
Anca Becze
M(Maria-Alexandra Resz (Hoaghia)
Maria-Alexandra Resz (Hoaghia)
Aranka IleaAranka Ilea
Aranka Ilea
Oana CadarOana Cadar
Oana Cadar
The quality of marketed pharmaceutical formulations must be guaranteed to attain better remedial effects and lower toxicity. The wide exploitation of antibiotics may lead to their presence as residues in body fluids and wastewaters, potentially toxic to human health. Consequently, determining antibiotics in pharmaceutical formulations and water samples is of significant importance. This paper aims to explore the possibilities of a high-performance liquid chromatography coupled with diode array detection (HPLC-DAD) method to obtain a simple, fast, and efficient analytical tool for the simultaneous determination of antibiotics in pharmaceutical formulations and environmental samples. The method was completely validated with regard to specificity, linearity, detection and quantification limits, precision, accuracy, and robustness according to the requirements of existing guidelines, and was proven to be reliable and suitable for the envisioned application. The linearity study was conducted for the calibration curves in the range of 10–100 μg/mL. The limits of detection and quantification were found to be 0.2 and 0.7 μg/mL for amoxicillin and 0.3 and 1.0 μg/mL for doxycycline, respectively. The high recovery of drugs from their commercial pharmaceutical formulations (93%) and from wastewater samples (98%) indicated good accuracy and precision. The method is robust for small or deliberate changes to the chromatographic parameters, and it was successfully applied for the quantitative determination of amoxicillin and doxycycline in wastewater and commercial tablets. The obtained results proved that the validated method is appropriate for its intended use in the routine quality control and assay of both antibiotics studied.