To quickly and accurately estimate the parameters of the fundamental positive- and negative-sequence under the unbalanced and distorted grid voltage, a synchronization method is presented in this paper. The proposed method is based on both a harmonic decoupling network consisting of multiple dual second-order generalized integrators (MDSOGIs) and an improved frequency locked loop (IFLL), so it is called the MDSOGI-IFLL. Due to the IFLL, the system has the feature that the dynamic performance of estimating the fundamental frequency is independent of the variation of both the fundamental positive- and negative-sequence voltage. In this paper, a first-order linear frequency adaption model is established for the design of the IFLL. Finally, the good performance of the proposed MDSOGI-IFLL is validated by the simulation and experiment.
By means of the mathematical morphology (MM) method, the power quality (PQ) disturbance signals can be monitored quickly and effective. However, the signal under investigation is often corrupted by noises, and the MM filter formed by fixed structure elements of can not handle this very well. In this paper, the theory and shortage of traditional MM theory are analyzed at first. And an improved MM (IMM) method is proposed. In this method, appropriate structural elements are selected and different structural elements and their self-adaptive weighted combinations are used to deal with perturbation signals. Also, the threshold method was used for reference, and it can improve the de-noising capability of the IMM method. In this way, the IMM method can carry out the de-noising and disturbance location task. Simulated results and practical application show that the proposed IMM method is practicable and possessed the advantages of simplicity, high calculation speed and easy hardware implementation.
To overcome the drawbacks of the proportional plus integral (PI) control based strategy, i.e., limitation for harmonic suppression and performance deterioration under load variation, a voltage control strategy based on the H∞ repetitive controller with inverter-side current feedback damping is proposed for the inverter in islanded microgrid. The H∞ repetitive controller provides good robustness against parameter perturbation and ensures the output voltage of low total harmonic distortion. Compared with other damping methods, a good resonance suppression and a better attenuation of the high-order harmonics can be achieved under the proposed strategy, which further improves the control performance of the voltage repetitive control system. A state space model including the damping coefficient is built to implement order reduction of the high-order controller, thereby simplifying the digital implementation while nearly without performance degradation. Moreover, the frequency response analysis shows that the order reduction can improve the adaptability of the controller to parameter variation. Finally, experiments and simulations verify the correctness of the analysis.
1 June 2018 in IOP Conference Series: Earth and Environmental Science
The distributed energy supply system(DESS) is widely used in power grids. This paper proposes a practical classification evaluation approach (PCEA) based on analytic hierarchy process-entropy weight method (AHP-EWM), with the goal of the quantitative evaluation values of DESS. Firstly, a practical evaluation index system (PEIS) considering soft competitiveness and hard competitiveness is constructed and scenes of DESS are classified into types under the consideration of developmental characteristics. Then, to break the hierarchies between intertypes and improve the fairness of evaluation results, an index-contributing coefficient (ICC) based on EWM is introduced to estimate the influence degree of different indexes on classification evaluation between different types of scenes. Next, with the input valuables of practical evaluation indexes from the PEIS, the classification evaluation results of DESSs are obtained by PCEA. Finally, the DESSs in southern part of China are taken for an example for analysis and further results verify the adaptability of PCEA.