Angus Ross Simpson

Prof. Angus Ross Simpson

School of Civil, Environmental and Mining Engineering, The University of Adelaide, Adelaide, South Australia, Australia
orcid

Research Focus & Metrics

Academic Career Length

36Years (1991-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2016 in Journal of Water Resources Planning and Management
Verified
Journal Article
Closed access
FZFeifei Zheng
Feifei Zheng
AZAaron C. Zecchin
Aaron C. Zecchin
HMHolger Robert Maier
Holger Robert Maier
Angus Ross SimpsonAngus Ross Simpson
Angus Ross Simpson
A number of multiobjective evolutionary algorithms (MOEAs) have been developed and applied to water resource optimization problems over the past decade. The comparative performance of these MOEAs has been investigated often according to their overall end-of-run results (quality of optimal fronts) within prespecified computational budgets. Despite the importance of such comparative analyses, these studies have provided little knowledge of how different MOEAs navigate through the decision space toward the Pareto front. To address this issue, this paper uses a range of metrics to quantitively characterize MOEAs’ run-time searching behavior, with a focus on the statistics of search quality and convergence progress. The metrics are applied to three state-of-the-art MOEAs, including the nondominated sorting genetic algorithm-II (NSGA-II), self-adaptive multiobjective differential evolution (SAMODE), and Borg, for six water distribution system (WDS) design problems with the objectives of minimizing netwo...

1 June 2013 in Journal of Hydraulic Engineering
Verified
Journal Article
Closed access
JGJames Gong
James Gong
MLMartin F. Lambert
Martin F. Lambert
Angus Ross SimpsonAngus Ross Simpson
Angus Ross Simpson
AZAaron C. Zecchin
Aaron C. Zecchin
Hydraulic transients (water hammer waves) can be used to excite a pressurized pipeline, yielding the frequency response diagram (FRD) of the system. The FRD of a pipeline system is useful for condition assessment and fault detection, because it is closely related to the physical properties of the pipeline. Most previous FRD-based leak detection techniques use the sinusoidal leak-induced pattern recorded on the FRD, either shown on the resonant responses or the antiresonant responses. In contrast, the technique reported in the current paper only uses the responses at the first three resonant frequencies to determine the location and size of a leak. The bandwidth of the excitation only needs to be five times that of the fundamental frequency of the tested pipeline, which is much less than the requirement in conventional FRD-based techniques. Sensitivity analysis and numerical simulations are performed to assess the robustness and applicable range of the proposed leak location technique. The proposed...

1 February 2013 in Journal of Pipeline Systems Engineering and Practice
Verified
Journal Article
Closed access
JGJames Gong
James Gong
Angus Ross SimpsonAngus Ross Simpson
Angus Ross Simpson
MLMartin F. Lambert
Martin F. Lambert
AZAaron C. Zecchin
Aaron C. Zecchin
YKYoung-Il Kim
Young-Il Kim
ATArris Tijsseling
Arris Tijsseling
A number of different methods that use signal processing of fluid transients (water hammer waves) for fault detection in pipes have been proposed in the past two decades. However, most of them focus solely on the detection of discrete deterioration, such as leaks or discrete blockages. Few studies have been conducted on the detection of distributed deterioration, such as extended sections of corrosion and extended blockages. This is despite the fact that they commonly exist and can have a severe negative impact on the operation of pipelines. The research reported here proposes a method of detecting distributed deterioration by investigating the time-domain water hammer response trace from a single pipe with a deteriorated section. Through wave analysis using a step pressure input, a theoretical square-shaped perturbation is found to exist in the transient pressure trace as a result of distributed deterioration. The hydraulic impedance of this section can be derived from the magnitude of the refle...

1 September 2012 in Journal of Water Resources Planning and Management
Verified
Journal Article
Closed access
WWWendy Wu
Wendy Wu
Angus Ross SimpsonAngus Ross Simpson
Angus Ross Simpson
HMHolger Robert Maier
Holger Robert Maier
AMAngela Marchi
Angela Marchi
Global warming caused by human activities presents serious global risks. Individuals, governments, and industries need to be more energy efficient and contribute to the mitigation of global warming by reducing their greenhouse gas (GHG) emissions. In previous research, GHG emission reduction has been identified as one important criterion in improving the sustainability of urban infrastructure and urban water systems. Within the water industry, opportunities exist for reducing GHG emissions by improving pumping efficiency via the use of variable-speed pumps (VSPs). Previously, VSPs have been used in the optimization of the operation of existing water distribution systems (WDSs). However, in WDS design optimization problems, fixed-speed pumps (FSPs) are commonly used. In this study, a pump power estimation method, developed using a false position method based optimization approach, is proposed to incorporate VSPs in the conceptual design or planning of water transmission systems (WTSs), using optimi...

1 February 2018 in Journal of Hydraulic Engineering
Verified
Journal Article
Closed access
JGJames Gong
James Gong
MLMartin F. Lambert
Martin F. Lambert
SNSi T. N. Nguyen
Si T. N. Nguyen
AZAaron C. Zecchin
Aaron C. Zecchin
Angus Ross SimpsonAngus Ross Simpson
Angus Ross Simpson
Research undertaken in the last two decades has demonstrated that hydraulic transient pressure waves, the phenomena behind water hammer, can be used as a tool for noninvasive and nondestructive condition assessment of long water transmission pipelines (in particular, detecting changes in the pipe wall properties). However, the spatial resolution of current transient-based technology is relatively low because the useful bandwidth of conventional valve-generated incident pressure waves is less than 100 Hz. This research develops a new transient pressure wave generator using controlled electrical sparks to provide high-frequency waves and improve the incident signal bandwidth. An electrical spark surrounded by water causes the development of a localized vapor cavity, the collapse of which induces an extremely sharp pressure pulse into the surrounding body of fluid. Experimental studies on a copper pipeline are conducted to investigate the usefulness of the pulse signals generated by the new spark generator for detecting thinner-walled pipe sections. Techniques are developed to analyze the wideband spark-induced pressure responses. The results show that the generated sharp pressure pulses have a useful frequency bandwidth up to 2 kHz. The success and accurate diagnosis of a thinner-walled section confirms that the dramatic improvement in bandwidth significantly enhances the spatial resolution of hydraulic transient-based pipe condition assessment.

1 September 2016 in Journal of Hydraulic Engineering
Verified
Journal Article
Closed access
JGJames Gong
James Gong
AZAaron C. Zecchin
Aaron C. Zecchin
MLMartin F. Lambert
Martin F. Lambert
Angus Ross SimpsonAngus Ross Simpson
Angus Ross Simpson
The determination of the creep (compliance) function of viscoelastic pipelines is essential for modeling their hydraulic behavior and accurately predicting pressure responses under transient events. This paper proposes a novel frequency-domain technique for the determination of the creep function of viscoelastic pipelines using hydraulic transients. A viscoelastic pipeline system, when compared with a frictionless elastic pipeline under the same system configuration, has nonuniformly shifted resonant frequencies. Analytical analysis shows that the shift in the resonant frequencies of a viscoelastic pipeline system is related to both the pipe wall viscoelastic compliance effects and the unsteady wall shear stress effects. A technique is developed to determine the elastic wave speed and the viscoelastic creep compliances based on the shifted system resonant frequencies. To improve the accuracy of the calibration for the viscoelastic parameters, an approach is proposed to correct the shifting in the ...