Retno Wigajatri Purnamaningsih

Dr. Retno Wigajatri Purnamaningsih


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 June 2019 in Photonics
Verified
Journal Article
Open access
PDF file
RPRetno Wigajatri Purnamaningsih
Retno Wigajatri Purnamaningsih
NPNji Raden Poespawati
Nji Raden Poespawati
Tomy AbuzairiTomy Abuzairi
Tomy Abuzairi
EL DOGHECHEEL DOGHECHE
EL DOGHECHE
This paper details the design of a 1 × 8 optical power divider, using a gallium nitride (GaN) semiconductor on sapphire, which can be applied to underwater optical wireless communication. The design consists of nine parallel rectangular waveguides which are based on mode coupling phenomena. Analysis of the design was performed using the beam propagation method (BPM). The optimization was conducted using the 3D finite difference (FD)-BPM method with an optical signal input at the wavelength required for maritime application of λ = 0.45 µm. The signal was injected into the central waveguide. The results showed that at a propagation length of 1480 µm the optical power is divided into eight output beams with an excess loss of 0.46 dB and imbalance of 0.51 dB. The proposed design can be further developed and applied in future underwater communication technology.

1 January 2018 in AIP Conference Proceedings
Verified
Conference Paper
Closed access
PDF file
RPRetno Wigajatri Purnamaningsih
Retno Wigajatri Purnamaningsih
AWAstari Widyakinanti
Astari Widyakinanti
ADArika Dhia
Arika Dhia
MGMuhammad Raditya Gumelar
Muhammad Raditya Gumelar
AWArif Widianto
Arif Widianto
HSHarry Soedibyo
Harry Soedibyo
We proposed a respiratory monitoring system for living activities in human body based on fiber optic macro-bending for laboratory scale. The respiration sensor consists of a single-mode optical fiber and operating on a wavelength at around 1550 nm. The fiber optic was integrated into an elastic fabric placed on the chest and stomach of the monitored human subject. Deformations of the flexible textile involving deformations of the fiber optic bending curvature, which was proportional to the chest and stomach expansion. The deformation of the fiber was detected using photodetector and processed using microcontroller PIC18F14K50. The results showed that this system able to display various respiration pattern and rate for sleeping, and after walking and running activities in real time.

1 January 2018 in AIP Conference Proceedings
Verified
Conference Paper
Closed access
PDF file
AWArif Widianto
Arif Widianto
INIntan Nurfitri
Intan Nurfitri
PMPradipta Mahatidana
Pradipta Mahatidana
TATomy Abuzairi
Tomy Abuzairi
NPN. R. Poespawati
N. R. Poespawati
RPRetno Wigajatri Purnamaningsih
Retno Wigajatri Purnamaningsih
We proposed weight monitoring system using load cell sensor for newborn incubator application. The weight sensing system consists of a load cell, conditioning signal circuit, and microcontroller Arduino Uno R3. The performance of the sensor was investigated by using the various weight from 0 up to 3000 g. Experiment results showed that this system has a small error of 4.313% and 12.5 g of threshold and resolution value. Compared to the typical baby scale available in local market, the proposed system has a lower error value and hysteresis.

1 January 2018 in AIP Conference Proceedings
Verified
Conference Paper
Open access
PDF file
ADArika Dhia
Arika Dhia
KDKresna Devara
Kresna Devara
Tomy AbuzairiTomy Abuzairi
Tomy Abuzairi
NPNji Raden Poespawati
Nji Raden Poespawati
RPRetno Wigajatri Purnamaningsih
Retno Wigajatri Purnamaningsih
This paper reports the design of respiratory sensor using fiber optic for newborn incubator application. The sensor works based on light intensity losses difference obtained due to thorax movement during respiration. The output of the sensor launched to support electronic circuits to be processed in Arduino Uno microcontroler such that the real-time respiratory rate (breath per minute) can be presented on LCD. Experiment results using thorax expansion of newborn simulator show that the system is able to measure respiratory rate from 10 up to 130 breaths per minute with 0.595% error and 0.2% hysteresis error.

22 July 2019 in Journal of Engineering
Verified
Journal Article
Open access
PDF file
RPRetno Wigajatri Purnamaningsih
Retno Wigajatri Purnamaningsih
NPNji Raden Poespawati
Nji Raden Poespawati
EL DOGHECHEEL DOGHECHE
EL DOGHECHE
This paper reports design of a simple four-branch optical power splitter using five parallel rectangular waveguides coupling in a gallium-nitride (GaN) semiconductor/sapphire for telecommunication links. The optimisation was conducted using the 3D FD-BPM method for long wavelength optical communication. The result shows that, at propagation length of 925 μm, the optical power input was successfully split into four uniform output beams, each with 24% of total input power. It is also shown that the relative output power distribution is almost stable through the C-band range. At the operating wavelength of 1.55 μm, the proposed power splitter has an excess loss lower than 0.2 dB. This study demonstrates the opportunity to develop optical interconnections from UV-Visible to near IR wavelengths.

7 December 2023 in International Journal of Technology
Verified
Journal Article
Closed access
NMNaufal Aiman Madani
Naufal Aiman Madani
RPRetno Wigajatri Purnamaningsih
Retno Wigajatri Purnamaningsih
NPNji Raden Poespawati
Nji Raden Poespawati
MHMaratul Hamidah
Maratul Hamidah
SRSasono Rahardjo
Sasono Rahardjo
DWDena Karunianto Wibowo
Dena Karunianto Wibowo
The aim of this study was to investigate the detection of low hydrostatic pressure, serving as the foundation for developing an underwater pressure sensor. This included creating a single-mode, uniformly structured Fiber Bragg Grating (FBG) with a stainless-steel coating. The experiment included loading the sensor with different volumes of fresh water ranging from 0 ml to 6 ml, in increments of 0.25 ml, in the perpendicular vertical direction. This volume range corresponded to hydrostatic pressures ranging from 0 Pa to 40.55 Pa. The experimental results showed a consistent linear relationship between low hydrostatic pressure and Bragg wavelength, implying a sensitivity of 0.8092 pm/Pa, according to theoretical expectations. Subsequently, mathematical simulations were conducted based on the results to predict the sensor performance under various potential seabed temperatures. The simulation results indicated that as the temperature rose, there was a corresponding increase in the reflected wavelength difference by 5.3754 ×10-9 nm/Pa for every 1°C increase in seawater temperature.