This paper presents the results of a series of pullout tests that were performed on Glass-fiber-reinforced polymer (GFRP) bars embedded in concrete, while providing a detailed report on the influence of various variables that impinge upon bond behavior, such as the surface characteristics and diameter of the bars, concrete strength, as well as the confined effect of stirrups. The Bertero-Popov-Eligehausen (BPE) and Cosenza-Manfredi-Realfonzo (CMR) models analyzed the bond stress (τ)–slip (s) relationship between GFRP bar and stirrups-confined concrete. The tests results indicate that when the bond failure interface only occurs on the surface of a GFRP bar, the bond strength is not dependent upon the concrete strength. Moreover, the results indicate that in comparison to specimens without stirrups, their stirrup-containing counterparts are more prone to pullout failure with greater ductility and higher bond strength and corresponding slip. The BPE and CMR models are able to investigate the τ-s relationship between GFRP bars and the stirrups-confined concrete with accuracy. With the experimental data, the specific parameters in the models classified by surface characteristics have been suggested.
A conventional method to study the durability of Glass Fiber Reinforced Polymer (GFRP) rebars is to carry out tensile tests on the corroded GFRP bars. The degree of corrosion of the GFRP bars could be quantified based on the measured ultimate tensile strength and the calculated strength reduction. However, it is difficult to directly monitor the reduction in tensile strength of the GFRP rebars that are embedded in concrete; therefore, this method cannot be implemented in real engineering practices. This study presents the reduction in elastic modulus of the GFPR rebars by real-time monitoring of the strain of the GFRP rebars, and then establishes the degradation model of the elastic modulus for the GFRP rebars in an alkaline corrosion environment. Therefore, the relationship between tensile strength and elastic modulus of GFRP rebars is proposed and verified by the experimental data obtained from the literature. The results show that it is feasible to use the Arrhenius equation to simulate the degradation model of the elastic modulus of the GFRP rebars. Thus, the tensile strength of the GFPR rebars can be related to its elastic modulus. Using the proposed relationship, the durability of GFRP rebars can be predicted by real-time monitoring of the elastic modulus of the GFRP rebars.
A new piezoelectric composite, macro fiber composite (MFC) is recombined with piezoceramic fibers, an epoxy resin basal body, and an interdigitated electrode. It has been widely applied in vibration reduction and deformation control of thin-walled structures, due to its great deformability and flexibility. Research on its actuation performance is mostly concentrated on the MFC actuating force calculation based on classical plate theory (CPT), and the overall modeling of MFC and its structure. However, they have some deficiencies in the tedious calculating process and neglect of shear deformation, respectively. To obtain a precise MFC actuating force, the sinusoidal shear deformation theory (SSDT) is adopted to deduce the MFC actuating force formula, and global–local displacement distribution functions are introduced to help the MFC laminated plate structure satisfy the deformation compatibility and stress balance. For instance, in the end displacement calculation of the MFC laminated beam structure. The experimental result of the MFC laminated beam is compared with those of the MFC actuating force based on SSDT and on CPT, which indicates that the MFC actuating force formula based on SSDT can reach higher computational accuracy.