Andrew Hazel

Andrew Hazel


Research Focus & Metrics

Academic Career Length

29Years (1998-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2004 in American Journal of Physiology-Heart and Circulatory Physiology
Verified
Journal Article
Closed access
PDF file
HHHeather A. Himburg
Heather A. Himburg
DGDeborah M. Grzybowski
Deborah M. Grzybowski
AHAndrew Hazel
Andrew Hazel
JLJeffrey A. LaMack
Jeffrey A. LaMack
XLXue-Mei Li
Xue-Mei Li
MFMorton H. Friedman
Morton H. Friedman
A better understanding of how hemodynamic factors affect the integrity and function of the vascular endothelium is necessary to appreciate more fully how atherosclerosis is initiated and promoted. A novel technique is presented to assess the relation between fluid dynamic variables and the permeability of the endothelium to macromolecules. Fully anesthetized, domestic swine were intravenously injected with the albumin marker Evans blue dye, which was allowed to circulate for 90 min. After the animals were euthanized, silicone casts were made of the abdominal aorta and its iliac branches. Pulsatile flow calculations were subsequently made in computational regions derived from the casts. The distribution of the calculated time-dependent wall shear stress in the external iliac branches was directly compared on a point-by-point basis with the spatially varying in vivo uptake of Evans blue dye in the same arteries. The results indicate that in vivo endothelial permeability to albumin decreases with increasing time-average shear stress over the normal range. Additionally, endothelial permeability increases slightly with oscillatory shear index.

26 March 2008 in Computational Mechanics
Verified
Journal Article
Closed access
PDF file
MHMatthias Heil
Matthias Heil
AHAndrew Hazel
Andrew Hazel
JBJonathan Boyle
Jonathan Boyle

21 January 2011 in Annual Review of Fluid Mechanics
Verified
Journal Article
Closed access
MHMatthias Heil
Matthias Heil
AHAndrew Hazel
Andrew Hazel
We provide a selective review of recent progress in the analysis of several physiological and physiologically inspired fluid-structure interaction problems, our aim being to explain the underlying physical mechanisms that cause the observed behaviors. Specifically, we discuss recent studies of self-excited oscillations in collapsible tubes, focusing primarily on studies of an idealized model system, the Starling resistor—a device used in most laboratory experiments. We next review studies of a particular physiological, flow-induced oscillation: vocal-fold oscillations during phonation. Finally, we discuss the closure and reopening of pulmonary airways, physiological fluid-structure interaction problems that also involve the airways' liquid lining.

1 July 1999 in Neurosurgery
Verified
Journal Article
Closed access
HUHiroshi Ujiie
Hiroshi Ujiie
HTHiroyuki Tachibana
Hiroyuki Tachibana
OHOsamu Hiramatsu
Osamu Hiramatsu
AHAndrew Hazel
Andrew Hazel
TMTakeshi Matsumoto
Takeshi Matsumoto
FKFumihiko Kajiya
Fumihiko Kajiya
The present study was undertaken to explore the relationship between the characteristic geometry of aneurysms prone to rupture and the blood flow patterns therein, using microsurgically produced aneurysms that simulated human middle cerebral artery aneurysms in scale and shape. We measured in vivo velocity profiles using our 20-MHz, 80-channel, Doppler ultrasound velocimeter. We produced small (≤5 mm, 5 cases) and large (6–13 mm, 12 cases) aneurysms with round, dumbbell, or multilobular shapes. The fundamental patterns of intra-aneurysmal flow were composed of inflow, circulating flow, and outflow. The inflow, which entered the aneurysm only during the systolic phase, was strongly influenced by the position and size of the neck and the flow ratio into the distal branches. The outflow was usually nonpulsatile and of low velocity. The circulating flow depended on the aspect ratio (depth/neck width). A single recirculation zone was observed in aneurysms with aspect ratios of less than 1.6. This circulation did not seem to extend to areas with aspect ratios greater than this value; in aneurysms with aspect ratios of more than 1.6, a much slower circulation was observed near the dome. Furthermore, in the dome of dumbbell-shaped aneurysms and daughter aneurysms, no flow was detected. Intra-aneurysmal flow was determined by the aspect ratio, rather than the aneurysm size. The localized, extremely low-flow condition that was observed in the dome of aneurysms with aspect ratios of more than 1.6 is a common flow characteristic in the geometry of ruptured aneurysms, so great care should be taken for patients with unruptured intracranial aneurysms with aspect ratios of more than 1.6.

1 January 2014 in Communications in Computational Physics
Verified
Journal Article
Closed access
PDF file
HDHenk A. Dijkstra
Henk A. Dijkstra
FWFred W. Wubs
Fred W. Wubs
ACAndrew K. Cliffe
Andrew K. Cliffe
EDEusebius Doedel
Eusebius Doedel
IDIoana F. Dragomirescu
Ioana F. Dragomirescu
UTUwe Thiele
Uwe Thiele
Numerical Bifurcation Methods and their Application to Fluid Dynamics: Analysis beyond Simulation - Volume 15 Issue 1 - Henk A. Dijkstra, Fred W. Wubs, Andrew K. Cliffe, Eusebius Doedel, Ioana F. Dragomirescu, Bruno Eckhardt, Alexander Yu. Gelfgat, Andrew L. Hazel, Valerio Lucarini, Andy G. Salinger, Erik T. Phipps, Juan Sanchez-Umbria, Henk Schuttelaars, Laurette S. Tuckerman, Uwe Thiele

5 November 2002 in Journal of Fluid Mechanics
Verified
Journal Article
Closed access
PDF file
AHAndrew Hazel
Andrew Hazel
MHMatthias Heil
Matthias Heil
This paper investigates the propagation of an air finger into a fluid-filled, axially uniform tube of elliptical or rectangular cross-section with transverse length scale a and aspect ratio α. Gravity is assumed to act parallel to the tube's axis. The problem is studied numerically by a finite-element-based direct solution of the free-surface Stokes equations.In rectangular tubes, our results for the pressure drop across the bubble tip, Δp, are in good agreement with the asymptotic predictions of Wong et al. (1995b) at low values of the capillary number, Ca (ratio of viscous to surface-tension forces). At larger Ca, Wong et al.'s (1995b) predictions are found to underestimate Δp. In both elliptical and rectangular tubes, the ratio Δp(α)/Δp(α = 1) is approximately independent of Ca and thus equal to the ratio of the static meniscus curvatures.In non-axisymmetric tubes, the air-liquid interface develops a noticeable asymmetry near the bubble tip at all values of the capillary number. The tip asymmetry decays with increasing distance from the bubble tip, but the decay rate becomes very small as Ca increases. For example, in a rectangular tube with α = 1.5, when Ca = 10, the maximum and minimum finger radii still differ by more than 10% at a distance 100a behind the finger tip. At large Ca the air finger ultimately becomes axisymmetric with radius r∞. In this regime, we find that r∞ in elliptical and rectangular tubes is related to r∞ in circular and square tubes, respectively, by a simple, empirical scaling law. The scaling has the physical interpretation that for rectangular and elliptical tubes of a given cross-sectional area, the propagation speed of an air finger, which is driven by the injection of air at a constant volumetric rate, is independent of the tube's aspect ratio.For smaller Ca (Ca < Ca), the air finger is always non-axisymmetric and the persisting draining flows in the thin film regions far behind the bubble tip ultimately lead to dry regions on the tube wall. Ca increases with increasing α and for α > αˆ dry spots will develop on the tube walls at all values of Ca.