Luana de Freitas Nascimento

Dr. Luana de Freitas Nascimento

orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 October 2022 in Physica Medica
Verified
Journal Article
Closed access
VVVerdi Vanreusel
Verdi Vanreusel
AGAlessia Gasparini
Alessia Gasparini
FGFederica Galante
Federica Galante
GMGiulia Mariani
Giulia Mariani
MPMatteo Pacitti
Matteo Pacitti
LNLuana de Freitas Nascimento
Luana de Freitas Nascimento

1 December 2014 in Radiation Measurements
Verified
Journal Article
Closed access
LNLuana de Freitas Nascimento
Luana de Freitas Nascimento
FVF. Vanhavere
F. Vanhavere
EBE. Boogers
E. Boogers
JVJ. Vandecasteele
J. Vandecasteele
YDYves De Deene
Yves De Deene

19 February 2013 in Radiation Measurements
Verified
Journal Article
Closed access
LNLuana de Freitas Nascimento
Luana de Freitas Nascimento
CSC.V. Saldarriaga
C.V. Saldarriaga
FVF. Vanhavere
F. Vanhavere
EDE. D'Agostino
E. D'Agostino
GDGilles Defraene
Gilles Defraene
YDYves De Deene
Yves De Deene

9 March 2018 in Sensors and Actuators A: Physical
Verified
Journal Article
Closed access
LNLuana de Freitas Nascimento
Luana de Freitas Nascimento
IVI. Veronese
I. Veronese
GLG. Loi
G. Loi
EME. Mones
E. Mones
FVF. Vanhavere
F. Vanhavere
DVDirk Verellen
Dirk Verellen

1 December 2018 in Radiation Measurements
Verified
Journal Article
Closed access
APAlessio Parisi
Alessio Parisi
LNLuana de Freitas Nascimento
Luana de Freitas Nascimento
OHOlivier Van Hoey
Olivier Van Hoey
PMPatrice MEGRET
Patrice MEGRET
HKHisashi Kitamura
Hisashi Kitamura
FVFilip Vanhavere
Filip Vanhavere

1 October 2020 in Physics and Imaging in Radiation Oncology
Verified
Journal Article
Open access
LNLuana de Freitas Nascimento
Luana de Freitas Nascimento
DVDirk Verellen
Dirk Verellen
JGJo Goossens
Jo Goossens
LSLara Struelens
Lara Struelens
FVFilip Vanhavere
Filip Vanhavere
MAMark Akselrod
Mark Akselrod
There is a continual need for more accurate and effective dosimetric systems for quality assurance (QA) as radiotherapy evolves in complexity. The purpose of this project was to introduce a new system that minimally perturbs the main beam, while assessing its real time 2D dose-rate and field shapes. The system combined reusability, linear dose-rate response, and high spatial and time resolution in a single radiation detection technology that can be applied to surface dose estimation and QA. We developed a 2D prototype system consisting of a camera, focusing lenses and short pass filter, placed on the head of a linear accelerator, facing an Al2O3:C,Mg radioluminescent film. To check the appropriateness of multi‐leaf collimator, stability/reproducibility QA tests were prepared using the treatment planning system: including the routinely used alternating leaves, chair and pyramid checks. The Al2O3:C,Mg film did not perturb the dose vs. depth dose curves determined with a point detector (-0.5% difference). Our results showed a dose-rate linear film response (R2 = 0.999), from 5 to 600 MU/min. Measured output factors agreed with reference data within ~1%, indicating a potential for small field dosimetry. Both chair and pyramid measured profiles were comparable with those obtained with the treatment planning system within 1%. The alternating leaves test showed an average discrepancy in the valleys of 14%. The prototype demonstrated promising results. It obviated the need for corrections regarding the relative position of the camera, confirming accurate dose-rate delivery and detection of radiation fields.