Polymer gel dosimeters are fabricated from radiation sensitive chemicals which, upon irradiation, polymerize as a function of the absorbed radiation dose. These gel dosimeters, with the capacity to uniquely record the radiation dose distribution in three-dimensions (3D), have specific advantages when compared to one-dimensional dosimeters, such as ion chambers, and two-dimensional dosimeters, such as film. These advantages are particularly significant in dosimetry situations where steep dose gradients exist such as in intensity-modulated radiation therapy (IMRT) and stereotactic radiosurgery. Polymer gel dosimeters also have specific advantages for brachytherapy dosimetry. Potential dosimetry applications include those for low-energy x-rays, high-linear energy transfer (LET) and proton therapy, radionuclide and boron capture neutron therapy dosimetries. These 3D dosimeters are radiologically soft-tissue equivalent with properties that may be modified depending on the application. The 3D radiation dose distribution in polymer gel dosimeters may be imaged using magnetic resonance imaging (MRI), optical-computerized tomography (optical-CT), x-ray CT or ultrasound. The fundamental science underpinning polymer gel dosimetry is reviewed along with the various evaluation techniques. Clinical dosimetry applications of polymer gel dosimetry are also presented.
One of the challenges in PET/MRI is the derivation of an attenuation map to correct the PET image for attenuation. Different methods have been suggested for deriving the attenuation map from an MR image. Because the low signal intensity of cortical bone on images acquired with conventional MRI sequences makes it difficult to detect this tissue type, these methods rely on some sort of anatomic precondition to predict the attenuation map, raising the question of whether these methods will be usable in the clinic when patients may exhibit anatomic abnormalities. Methods: We propose the use of the transverse relaxation rate, derived from images acquired with an ultrashort echo time sequence to classify the voxels into 1 of 3 tissue classes (bone, soft tissue, or air), without making any assumptions on patient anatomy. Each voxel is assigned a linear attenuation coefficient corresponding to its tissue class. A reference CT scan is used to determine the voxel-by-voxel accuracy of the proposed method. The overall accuracy of the MRI-based attenuation correction is evaluated using a method that takes into account the nonlocal effects of attenuation correction. Results: As a proof of concept, the head of a pig was used as a phantom for imaging. The new method yielded a correct tissue classification in 90% of the voxels. Five human brain PET/CT and MRI datasets were also processed, yielding slightly worse voxel-by-voxel performance, compared to a CT-derived attenuation map. The PET datasets were reconstructed using the segmented MRI attenuation map derived with the new method, and the resulting images were compared with segmented CT-based attenuation correction. An average error of around 5% was found in the brain. Conclusion: The feasibility of using the transverse relaxation rate map derived from ultrashort echo time MR images for the estimation of the attenuation map was shown on phantom and clinical brain data. The results indicate that the new method, compared with CT-based attenuation correction, yields clinically acceptable errors. The proposed method does not make any assumptions about patient anatomy and could therefore also be used in cases in which anatomic abnormalities are present.
To assess the diagnostic value of parametric magnetic resonance images that display the first pass (FP) of gadopentetate dimeglumine. Dynamic, contrast material-enhanced, fast low-angle shot MR imaging was performed of 100 musculoskeletal lesions in 36 female and 64 male patients (aged 9-81 years [mean, 34 years]). The highest slope value of the time-intensity curve was calculated pixel by pixel and displayed on the FP image, with a gray-scale value equal to the slope value. Tissue vascularization and perfusion were evaluated at pathologic and angiographic examinations in 33 lesions. A significant difference (P < .001) was found between the FP slope values of benign (mean, 36.2% per second) and malignant (mean, 67.4% per second) lesions. FP images depicted tissue vascularization and perfusion rather than benignity or malignancy, because there is an overlap in the slope values of highly vascular benign lesions and malignant lesions. FP images provide diagnostically useful information by depicting tissue vascularization and perfusion.
Polymer gel dosimeters offer a wide range of applications in the three-dimensional verification of complex dose distributions such as in intensity-modulated radiotherapy. One of the major difficulties with polymer gel dosimeters is their sensitivity to oxygen, as oxygen inhibits the radiation-induced polymerization reaction. For several years, oxygen was removed from the gels by bubbling the sol with inert gases for several hours during the gel fabrication. Also, the gel had to be poured in containers with low oxygen permeability and solubility. Recently, it was found that these technical difficulties can easily be solved by adding an antioxidant to the gel. These gels are called 'normoxic' gels as they can be produced under normal atmospheric conditions. In this study several properties of polymer gel dosimeters have been investigated: the dose sensitivity, the temporal and spatial stability of the gel, the sensitivity of the dose response to temperature during irradiation and during MR imaging, the energy dependence and the dose-rate dependence. This study reveals that the normoxic polymer gel dosimeter based on methacrylic acid (nMAG) studied in this work has inferior radiation properties as compared to the polyacrylamide gelatine (PAG) gel dosimeters. It is shown that from the three different gel dosimeters investigated in this study, the nPAG gel dosimeter results in a less sensitive gel dosimeter but with superior radiation properties as compared to the nMAG gel dosimeter. The importance of investigating relevant radiation properties of gel dosimeters apart from the radiation sensitivity-prior to their use for dosimetric validation experiments-is illustrated and emphasized throughout this study. Other combinations of monomer and gelling agent may result in more reliable normoxic polymer gel dosimeters.
16 September 2002 in Physics in Medicine & Biology
Polymer gel dosimeters offer a wide range of potential applications in the three-dimensional verification of complex dose distribution such as in intensity-modulated radiotherapy (IMRT). Until now, however, polymer gel dosimeters have not been widely used in the clinic. One of the reasons is that they are difficult to manufacture. As the polymerization in polymer gels is inhibited by oxygen, all free oxygen has to be removed from the gels. For several years this was achieved by bubbling nitrogen through the gel solutions and by filling the phantoms in a glove box that is perfused with nitrogen. Recently another gel formulation was proposed in which oxygen is bound in a metallo-organic complex thus removing the problem of oxygen inhibition. The proposed gel consists of methacrylic acid, gelatin, ascorbic acid, hydroquinone and copper(II)sulphate and is given the acronym MAGIC gel dosimeter. These gels are fabricated under normal atmospheric conditions and are therefore called 'normoxic' gel dosimeters. In this study, a chemical analysis on the MAGIC gel was performed. The composition of the gel was varied and its radiation response was evaluated. The role of different chemicals and the reaction kinetics are discussed. It was found that ascorbic acid alone was able to bind the oxygen and can thus be used as an anti-oxidant in a polymer gel dosimeter. It was also found that the anti-oxidants N-acetyl-cysteine and tetrakis(hydroxymethyl)phosphonium were effective in scavenging the oxygen. However, the rate of oxygen scavenging is dependent on the anti-oxidant and its concentration with tetrakis(hydroxymethyl)phosphonium being the most reactive anti-oxidants. Potentiometric oxygen measurements in solution provide an easy way to get a first impression on the rate of oxygen scavenging. It is shown that cupper(II)sulphate operates as a catalyst in the oxidation of ascorbic acid. We, therefore, propose some new normoxic gel formulations that have a less complicated chemical formulation than the MAGIC gel.