Objective: Continuous glucose monitoring (CGM) enables prediction of the future glucose concentration (GC) trajectory for making informed diabetes management decisions. The glucose concentration values are affected by various physiological and metabolic variations, such as physical activity (PA) and acute psychological stress (APS), in addition to meals and insulin. In this work, we extend our adaptive glucose modeling framework to incorporate the effects of PA and APS on the GC predictions. Methods: A wristband conducive of use by free-living ambulatory people is used. The measured physiological variables are analyzed to generate new quantifiable input features for PA and APS. Machine learning techniques estimate the type and intensity of the PA and APS when they occur individually and concurrently. Variables quantifying the characteristics of both PA and APS are integrated as exogenous inputs in an adaptive system identification technique for enhancing the accuracy of GC predictions. Data from clinical experiments illustrate the improvement in GC prediction accuracy. Results: The average mean absolute error (MAE) of one-hour-ahead GC predictions with testing data decreases from 35.1 to 31.9 mg/dL (p-value = 0.01) with the inclusion of PA information, and it decreases from 16.9 to 14.2 mg/dL (p-value = 0.006) with the inclusion of PA and APS information. Conclusion: The first-ever glucose prediction model is developed that incorporates measures of physical activity and acute psychological stress to improve GC prediction accuracy. Significance: Modeling the effects of physical activity and acute psychological stress on glucose concentration values will improve diabetes management and enable informed meal, activity and insulin dosing decisions.
Algorithms that can determine the type of physical activity (PA) and quantify the intensity can allow precision medicine approaches, such as automated insulin delivery systems that modulate insulin administration in response to PA. In this work, data from a multi-sensor wristband is used to design classifiers to distinguish among five different physical states (PS) (resting, activities of daily living, running, biking, and resistance training), and to develop models to estimate the energy expenditure (EE) of the PA for diabetes therapy. The data collected are filtered, features are extracted from the reconciled signals, and the extracted features are used by machine learning algorithms, including deep-learning techniques, to obtain accurate PS classification and EE estimation. The various machine learning techniques have different success rates ranging from 75.7% to 94.8% in classifying the five different PS. The deep neural network model with long short-term memory has 94.8% classification accuracy. We achieved 0.5 MET (Metabolic Equivalent of Task) root-mean-square error for EE estimation accuracy, relative to indirect calorimetry with randomly selected testing data (10% of collected data). We also demonstrate a 5% improvement in PS classification accuracy and a 0.34 MET decrease in the mean absolute error when using multi-sensor approach relative to using only accelerometer data.
17 December 2020 in Computer Methods and Programs in Biomedicine
An artificial pancreas (AP) computes the optimal insulin dose to be infused through an insulin pump in people with Type 1 Diabetes (T1D) based on information received from a continuous glucose monitoring (CGM) sensor. It has been recognized that exercise is a major challenge in the development of an AP system. The use of biometric physiological variables in an AP system may be beneficial for prevention of exercise-induced challenges and better glucose regulation. The goal of the present study is to find a correlation between biometric variables such as heart rate (HR), heat flux (HF), skin temperature (ST), near-body temperature (NBT), galvanic skin response (GSR), and energy expenditure (EE), 2D acceleration-mean of absolute difference (MAD) and changes in glucose concentrations during exercise via partial least squares (PLS) regression and variable importance in projection (VIP) in order to determine which variables would be most useful to include in a future artificial pancreas. PLS and VIP analyses were performed on data sets that included seven different types of exercises. Data were collected from 26 clinical experiments. Clinical results indicate ST to be the most consistently important (important for six out of seven tested exercises) variable over all different exercises tested. EE and HR are also found to be important variables over several types of exercise. We also found that the importance of GSR and NBT observed in our experiments might be related to stress and the effect of changes in environmental temperature on glucose concentrations. The use of the biometric measurements in an AP system may provide better control of glucose concentration.