Mudassir M. Rashid

Dr. Mudassir M. Rashid

Illinois Institute of Technology
orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications



17 June 2021 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
Mert SevilMert Sevil
Mert Sevil
Mudassir M. RashidMudassir M. Rashid
Mudassir M. Rashid
IHIman Hajizadeh
Iman Hajizadeh
MPMinsun Park
Minsun Park
LQLaurie Quinn
Laurie Quinn
ACAli Cinar
Ali Cinar
Objective: Continuous glucose monitoring (CGM) enables prediction of the future glucose concentration (GC) trajectory for making informed diabetes management decisions. The glucose concentration values are affected by various physiological and metabolic variations, such as physical activity (PA) and acute psychological stress (APS), in addition to meals and insulin. In this work, we extend our adaptive glucose modeling framework to incorporate the effects of PA and APS on the GC predictions. Methods: A wristband conducive of use by free-living ambulatory people is used. The measured physiological variables are analyzed to generate new quantifiable input features for PA and APS. Machine learning techniques estimate the type and intensity of the PA and APS when they occur individually and concurrently. Variables quantifying the characteristics of both PA and APS are integrated as exogenous inputs in an adaptive system identification technique for enhancing the accuracy of GC predictions. Data from clinical experiments illustrate the improvement in GC prediction accuracy. Results: The average mean absolute error (MAE) of one-hour-ahead GC predictions with testing data decreases from 35.1 to 31.9 mg/dL (p-value = 0.01) with the inclusion of PA information, and it decreases from 16.9 to 14.2 mg/dL (p-value = 0.006) with the inclusion of PA and APS information. Conclusion: The first-ever glucose prediction model is developed that incorporates measures of physical activity and acute psychological stress to improve GC prediction accuracy. Significance: Modeling the effects of physical activity and acute psychological stress on glucose concentration values will improve diabetes management and enable informed meal, activity and insulin dosing decisions.

2 September 2019 in Computers & Chemical Engineering
Verified
Journal Article
Closed access
Mudassir M. RashidMudassir M. Rashid
Mudassir M. Rashid
SSSediqeh Samadi
Sediqeh Samadi
Mert SevilMert Sevil
Mert Sevil
IHIman Hajizadeh
Iman Hajizadeh
PKPaul Kolodziej
Paul Kolodziej
ACAli Cinar
Ali Cinar

8 June 2020 in IEEE Sensors Journal
Verified
Journal Article
Closed access
Mert SevilMert Sevil
Mert Sevil
Mudassir M. RashidMudassir M. Rashid
Mudassir M. Rashid
ZMZacharie Maloney
Zacharie Maloney
IHIman Hajizadeh
Iman Hajizadeh
SSSediqeh Samadi
Sediqeh Samadi
ACAli Cinar
Ali Cinar
Algorithms that can determine the type of physical activity (PA) and quantify the intensity can allow precision medicine approaches, such as automated insulin delivery systems that modulate insulin administration in response to PA. In this work, data from a multi-sensor wristband is used to design classifiers to distinguish among five different physical states (PS) (resting, activities of daily living, running, biking, and resistance training), and to develop models to estimate the energy expenditure (EE) of the PA for diabetes therapy. The data collected are filtered, features are extracted from the reconciled signals, and the extracted features are used by machine learning algorithms, including deep-learning techniques, to obtain accurate PS classification and EE estimation. The various machine learning techniques have different success rates ranging from 75.7% to 94.8% in classifying the five different PS. The deep neural network model with long short-term memory has 94.8% classification accuracy. We achieved 0.5 MET (Metabolic Equivalent of Task) root-mean-square error for EE estimation accuracy, relative to indirect calorimetry with randomly selected testing data (10% of collected data). We also demonstrate a 5% improvement in PS classification accuracy and a 0.34 MET decrease in the mean absolute error when using multi-sensor approach relative to using only accelerometer data.