Three-phase dynamic systems and multiphase generators are frequently modeled and controlled in the synchronous reference frame. To properly model the cross-coupling terms in this reference frame, complex vector theory and transfer function matrices are commonly applied, obtaining multiple-input multiple output (MIMO) dynamic models. The stability of MIMO systems can be assessed through the Nyquist Generalized Stability Criterion. However, the use of the Nyquist diagram complicates the controller design. The Bode diagram is a more intuitive tool for the controller design, however, the Bode Stability Criterion is not applicable to MIMO systems. In this paper, the MIMO Generalized Bode Criterion is proposed. Since this stability criterion is based on the Nyquist Generalized Stability Criterion it can be applied to any system. Furthermore, it is simple to use, as it only requires information contained in the open-loop transfer matrix and the Bode diagram. The proposed stability criterion thus offers an interesting tool for the controller design procedure in MIMO systems, as it is shown in in this paper for two common applications: the current control loop of a power converter, a 2×2 system, and the current control loop of two independent power converters in parallel, a 4×4 system.
As the main difficulty of modeling cavity receivers is determining natural convection heat losses, this paper presents a survey of the different natural convection correlations developed by several authors to model natural convective heat losses from cavity receivers of solar thermal power tower plants. The different correlations studied for modeling convective heat losses are later compared by performing simulations on an implemented cavity receiver. For this work a model of a PS10-like cavity receiver, using Solar Salt as the heat transfer fluid, is implemented in Modelica. The simulations have shown how the results of four out of the five studied correlations do agree, while one of the analyzed correlations clearly overestimates convective heat losses for the simulations performed
1 February 2019 in International Journal of Electrical Power & Energy Systems
Doubly-fed induction generator (DFIG) wind turbines connected to capacitive series-compensated transmission lines are prone to exhibit oscillatory behavior. The phenomena is called sub-synchronous resonances (SSRs), as these oscillations occur at frequencies below the fundamental component. This paper first develops a modeling methodology for DFIG wind turbines, based on impedance matrices, that is applied to model a real wind farm where SSRs were reported. The stability analysis performed shows how the interaction between the grid-side converter and the rotor-side converter contribute to the instability of DFIG wind energy conversion systems connected to series compensated grids. With this model, we propose a simple sub-synchronous resonance control strategy based on an orthogonal proportional action applied to the rotor currents, and a variable gain in the PI controller adjusted as a function of the DFIG rotational speed. This control strategy depends only on the rotor currents, which are local and already measured variables in any DFIG wind turbine, and is implemented in the rotor side converter, so it does not imply an additional cost at wind farm or wind turbine level and can be applied to any DFIG wind energy conversion system (WECS). Additionally, it proves to be robust for any line impedance series compensation level, and it does not need real-time information concerning the grid at which the wind turbine is connected, or its parameters. A real case study is considered, where the sub-synchronous resonance damping strategy presented in this work is able to stabilize the system for every possible line impedance compensation level.
Traditionally, to characterize the response of droop-controlled systems RMS models have been used. However, as it is demonstrated in this work, when droop control is applied to doubly-fed induction generators, RMS models do not allow to predict the system stability and dynamic response. Thus, in this article, a linearized small-signal model that overcomes the limitations of RMS models is presented. The proposed model is validated by simulation in MATLAB/Simulink demonstrating that it allows to accurately analyze the stability and dynamic response of the system under study. This model is an interesting tool that can be used in future works to design and adjust grid-forming controllers for doubly-fed induction generators.