This paper compares the structural design of two organic biosensors that minimize power consumption in wireless photoplethysmogram (PPG) waveform monitoring. Both devices were fabricated on the same substrate with a red organic light-emitting diode (OLED) and an organic photodiode (OPD). Both were designed with a circular OLED at the center of the device surrounded by OPD. One device had an OLED area of 0.06 cm2, while the other device had half the area. The gap distance between the OLED and OPD was 1.65 mm for the first device and 2 mm for the second. Both devices had an OPD area of 0.16 cm2. We compared the power consumption and signal-to-noise ratio (SNR) of both devices and evaluated the PPG signal, which was successfully collected from a fingertip. The reflectance-based organic pulse meter operated successfully and at a low power consumption of 8 µW at 18 dB SNR. The device sent the PPG waveforms, via Bluetooth low energy (BLE), to a PC host at a maximum rate of 256 kbps data throughput. In the end, the proposed reflectance-based organic pulse meter reduced power consumption and improved long-term PPG wireless monitoring.
This paper demonstrated a new design structure for minimizing the power consumption of a pulse meter. Monolithic devices composed of a red (625 nm) organic light-emitting diode (OLED) and an organic photodiode (OPD) were fabricated on the same substrate. Two organic devices were designed differently. One had a circle-shaped OLED in the center of the device and was surrounded by the OPD, while the other had the opposite structure. The external quantum efficiency (EQE) of the OLED and the OPD were 7% and 37%, respectively. We evaluated and compared the signal-to-noise ratio (SNR) of the photoplethysmogram (PPG) signal on different parts of the body and successfully acquired clear PPG signals at those positions, where the best signal was obtained from the fingertip at a SNR of about 62 dB. The proposed organic pulse meter sensor was operated successfully with a power consumption of 0.1 mW. Eventually, the proposed organic biosensor reduced the power consumption and improved the capability of the pulse meter for long-term use.
This paper introduces scaling-factor and design guidelines for shielded-capacitive power transfer (shielded-CPT) systems, offering a simplified design process, coupling-structure optimization, and consideration of safety. A novel scaling-factor-analysis method is proposed by determining the configuration of the coupling structure that improves system safety and increases operating efficiency while minimizing the gap between the shield and the coupler plate. The inductor-series resistance is also analyzed to study the loss efficiency in the shielded-CPT system. The relationship among the shield-coupler gap, distance between the couplers, conductive-plate size, and delivered power is examined and presented. The proposed method is validated by implementing the shielded-CPT system with hardware and the result suggests that the proposed method can be used to design shielded-CPT systems with scaling-factor and safety considerations.
This paper introduces a DC–DC buck converter on the secondary side of the capacitive power transfer system to reduce the voltage and electric field across the interface, and to reduce the circuit Q, and thus the system sensitivity. The system is mathematically analyzed to study the improvement in sensitivity and voltage stress. The leakage electric field emissions around the plates are investigated by simulation. The analytical and simulation results show that by reducing the duty cycle of the buck converter at a constant output power, the voltage across the plates can be significantly reduced and the circuit becomes less sensitive to the variations in parameters. Experimental results demonstrated that Q and the voltage stress over the capacitive interface are reduced by changing the duty cycle of the buck converter. For delivering 10 W of power, the maximum voltage stress across one pair of the coupling plates is reduced from 211 V in the conventional system without using a DC–DC converter, to 65 V and 44 V at duty cycles of 30% and 20%, respectively. The system achieves an end-to-end power efficiency of 80% at an output power of 10 W and a duty cycle of 30%.
The temperature dependence thermal conductivity of the indium-gallium-zinc oxide (IGZO) thin films was investigated with the differential three-omega method for the clear demonstration of nanocrystallinity. The thin films were deposited on an alumina (α-Al2O3) substrate by direct current (DC) magnetron sputtering at different oxygen partial pressures ([PO2] = 0%, 10%, and 65%). Their thermal conductivities at room temperature were measured to be 1.65, 1.76, and 2.58 Wm−1K−1, respectively. The thermal conductivities decreased with an increase in the ambient measurement temperature. This thermal property is similar to that of crystalline materials. Electron microscopy observations revealed the presence of nanocrystals embedded in the amorphous matrix of the IGZO films. The typical size of the nanocrystals was approximately 2–5 nm with the lattice distance of about 0.24–0.26 nm. These experimental results indicate that the nanocrystalline microstructure controls the heat conduction in the IGZO films.
A capacitive power transfer (CPT) system wirelessly transfers energy between coupling plates and performance issues related to CPT systems are resonance conditions, matching impedance, voltage stress, and power loss. A generalized circuit model is proposed for shielded capacitive power transfer (S-CPT) using an algebraic method. The proposed generalized S-CPT model is analyzed based on the symmetric and asymmetric configurations, and the relationship between the parameters of S-CPT is obtained with respect to the resonance condition, matching impedance, voltage stress, and efficiency. The best configuration of a symmetric S-CPT is recommended, and an asymmetric S-CPT is proposed based on the analysis results. Asymmetric-S-CPT hardware was constructed and demonstrated an operating frequency of 13.56 MHz. The hardware experimental result shows the validity and effectiveness of the proposed generalized model for designing S-CPT.