Hinnerk Schulz-Hildebrandt

Dr. Hinnerk Schulz-Hildebrandt

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 August 2020 in Optics Letters
Verified
Journal Article
Closed access
MMMichael Muenter
Michael Muenter
MEMalte Vom Endt
Malte Vom Endt
MPMario Pieper
Mario Pieper
MCMalte Casper
Malte Casper
MAMartin Ahrens
Martin Ahrens
HSHinnerk Schulz-Hildebrandt
Hinnerk Schulz-Hildebrandt
While optical coherence tomography (OCT) provides a resolution down to 1 µm, it has difficulties in visualizing cellular structures due to a lack of scattering contrast. By evaluating signal fluctuations, a significant contrast enhancement was demonstrated using time-domain full-field OCT (FF-OCT), which makes cellular and subcellular structures visible. The putative cause of the dynamic OCT signal is the site-dependent active motion of cellular structures in a sub-micrometer range, which provides histology-like contrast. Here we demonstrate dynamic contrast with a scanning frequency-domain OCT (FD-OCT), which we believe has crucial advantages. Given the inherent sectional imaging geometry, scanning FD-OCT provides depth-resolved images across tissue layers, a perspective known from histopathology, much faster and more efficiently than FF-OCT. Both shorter acquisition times and tomographic depth-sectioning reduce the sensitivity of dynamic contrast for bulk tissue motion artifacts and simplify their correction in post-processing. Dynamic contrast makes microscopic FD-OCT a promising tool for the histological analysis of unstained tissues.

6 September 2019 in International Journal of Computer Assisted Radiology and Surgery
Verified
Journal Article
Open access
PDF file
SJSonja Jäckle
Sonja Jäckle
TETim Eixmann
Tim Eixmann
HSHinnerk Schulz-Hildebrandt
Hinnerk Schulz-Hildebrandt
GHGereon Hüttmann
Gereon Hüttmann
TPTorben Pätz
Torben Pätz
Purpose Endovascular aortic repair procedures are currently conducted with 2D fluoroscopy imaging. Tracking systems based on fiber Bragg gratings are an emerging technology for the navigation of minimally invasive instruments which can reduce the X-ray exposure and the used contrast agent. Shape sensing of flexible structures is challenging and includes many calculations steps which are prone to different errors. To reduce this errors, we present an optimized shape sensing model. Methods We analyzed for every step of the shape sensing process, which errors can occur, how the error affects the shape and how it can be compensated or minimized. Experiments were done with one multicore fiber system with 38 cm sensing length, and the effects of different methods and parameters were analyzed. Furthermore, we compared 3D shape reconstructions with the segmented shape of the corresponding CT scans of the fiber to evaluate the accuracy of our optimized shape sensing model. Finally, we tested our model in a realistic endovascular scenario by using a 3D printed vessel system created from patient data. Results Depending on the complexity of the shape, we reached an average error of 0.35–1.15 mm and maximal error of 0.75–7.53 mm over the whole 38 cm sensing length. In the endovascular scenario, we obtained an average and maximal error of 1.13 mm and 2.11 mm, respectively. Conclusion The accuracies of the 3D shape sensing model are promising, and we plan to combine the shape sensing based on fiber Bragg gratings with the position and orientation of an electromagnetic tracking to obtain the located catheter shape.

7 September 2021 in Biomedical Optics Express
Verified
Journal Article
Closed access
MMMichael Muenter
Michael Muenter
MPMario Pieper
Mario Pieper
TKTabea Kohlfaerber
Tabea Kohlfaerber
EBErnst Bodenstorfer
Ernst Bodenstorfer
MAMartin Ahrens
Martin Ahrens
HSHinnerk Schulz-Hildebrandt
Hinnerk Schulz-Hildebrandt
Volumetric imaging of dynamic processes with microscopic resolution holds a huge potential in biomedical research and clinical diagnosis. Using supercontinuum light sources and high numerical aperture (NA) objectives, optical coherence tomography (OCT) achieves microscopic resolution and is well suited for imaging cellular and subcellular structures of biological tissues. Currently, the imaging speed of microscopic OCT (mOCT) is limited by the line-scan rate of the spectrometer camera and ranges from 30 to 250 kHz. This is not fast enough for volumetric imaging of dynamic processes in vivo and limits endoscopic application. Using a novel CMOS camera, we demonstrate fast 3-dimensional OCT imaging with 600,000 A-scans/s at 1.8 µm axial and 1.1 µm lateral resolution. The improved speed is used for imaging of ciliary motion and particle transport in ex vivo mouse trachea. Furthermore, we demonstrate dynamic contrast OCT by evaluating the recorded volumes rather than en face planes or B-scans. High-speed volumetric mOCT will enable the correction of global tissue motion and is a prerequisite for applying dynamic contrast mOCT in vivo. With further increase in imaging speed and integration in flexible endoscopes, volumetric mOCT may be used to complement or partly replace biopsies.

5 May 2022 in Biomedical Optics Express
Verified
Journal Article
Closed access
TKTabea Kohlfaerber
Tabea Kohlfaerber
MPMario Pieper
Mario Pieper
MMMichael Muenter
Michael Muenter
CHCornelia Holzhausen
Cornelia Holzhausen
MAMartin Ahrens
Martin Ahrens
HSHinnerk Schulz-Hildebrandt
Hinnerk Schulz-Hildebrandt
In the imaging of airway tissue, optical coherence tomography (OCT) provides cross-sectional images of tissue structures, shows cilia movement and mucus secretion, but does not provide sufficient contrast to differentiate individual cells. By using fast sequences of microscopic resolution OCT (mOCT) images, OCT can use small signal fluctuations to overcome lack in contrast and speckle noise. In this way, OCT visualizes airway morphology on a cellular level and allows the tracking of the dynamic behavior of immune cells, as well as mucus transport and secretion. Here, we demonstrate that mOCT, by using temporal tissue fluctuation as contrast (dynamic mOCT), provides the possibility to study physiological and pathological tissue processes in vivo.

28 July 2018 in International Journal of Computer Assisted Radiology and Surgery
Verified
Journal Article
Closed access
PDF file
MOM. Ourak
M. Ourak
JSJonas Victor Harmen Smits
Jonas Victor Harmen Smits
LEL. Esteveny
L. Esteveny
GBGianni Borghesan
Gianni Borghesan
AGA. Gijbels
A. Gijbels
EPEmmanuel Benjamin Vander Poorten
Emmanuel Benjamin Vander Poorten

1 November 2017 in Investigative Ophthalmology & Visual Science
Verified
Journal Article
Open access
PDF file
JHJens Horstmann
Jens Horstmann
HSHinnerk Schulz-Hildebrandt
Hinnerk Schulz-Hildebrandt
FBFelix Bock
Felix Bock
SSSebastian Siebelmann
Sebastian Siebelmann
ELEva Lankenau
Eva Lankenau
CCClaus Cursiefen
Claus Cursiefen
Purpose: Corneal neovascularization, in particular lymphangiogenesis, is a limiting factor in corneal transplant survival. Novel treatment approaches focus on (selective) inhibition and regression of lymphatic vessels. Imaging clinically invisible corneal lymphatic vessels is a prerequisite for these strategies. Using a murine model, this study investigates whether corneal lymphatic vessels can be imaged using microscopic optical coherence tomography (mOCT). Methods: Corneal neovascularization was induced by intrastromal placement of 11.0 nylon sutures in one eye of BALB/c mice. After 2 weeks, cross-sectional images and volumes of the corneas with a 0.5 mm lateral and axial field of view were acquired using a custom-built mOCT system enabling a resolution of 1 μm at a B-scan rate of 165/s. Three of the six animals received an additional intrastromal injection of India ink 24 hours before the measurement to stain the corneal lymphatic system in vivo. Immunohistochemistry using CD31 and LYVE-1 was used to validate the mOCT findings. Results: Using mOCT, lymphatic vessels were visible as dark vessel-like structures with the lumen lacking a hyperreflective wall and mostly lacking cells. However, individual, slowly moving particles, which most likely are immune cells, occasionally could be observed inside the lumen. In lymphatic vessels of ink-stained corneas, hyperreflection and shadowing underneath was observed. Ink-filled lymphatic vessels were colocalized in consecutive corneal flat mounts of the same specimen. Conclusions: Corneal lymphatic vessels can be imaged using mOCT. This novel approach opens new options for noninvasive clinical imaging of corneal lymphatic vessels for diagnostic and therapeutic indications.