Rasaq LAMIDI

Dr. Rasaq LAMIDI


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2019 in Applied Energy
Verified
Journal Article
Closed access
RLRasaq LAMIDI
Rasaq LAMIDI
LJLong Jiang
Long Jiang
Pankaj B. PatharePankaj B. Pathare
Pankaj B. Pathare
Yaodong WangYaodong Wang
Yaodong Wang
ARA.P. Roskilly
A.P. Roskilly

1 December 2017 in Energy Procedia
Verified
Journal Article
Open access
MAMarcelo Calispa Aguilar
Marcelo Calispa Aguilar
Yaodong WangYaodong Wang
Yaodong Wang
TRTony Roskilly
Tony Roskilly
Pankaj B. PatharePankaj B. Pathare
Pankaj B. Pathare
RLRasaq LAMIDI
Rasaq LAMIDI

1 September 2019 in Energy Conversion and Management
Verified
Journal Article
Closed access
RLRasaq LAMIDI
Rasaq LAMIDI
LJLong Jiang
Long Jiang
Yaodong WangYaodong Wang
Yaodong Wang
Pankaj B. PatharePankaj B. Pathare
Pankaj B. Pathare
ARA.P. Roskilly
A.P. Roskilly

12 March 2018 in Water
Verified
Journal Article
Open access
PDF file
NENuri Eshoul
Nuri Eshoul
Abdulrahman AlmutairiAbdulrahman Almutairi
Abdulrahman Almutairi
RLRasaq LAMIDI
Rasaq LAMIDI
HAHamad Alhajeri
Hamad Alhajeri
AAABDULRAHMAN ALENEZI
ABDULRAHMAN ALENEZI
Desalination is the sole proven technique that can provide the necessary fresh water in arid and semi-arid countries in sufficient quantities and meet the modern needs of a growing world population. Multi effect desalination with thermal vapour compression (MED-TVC) is one of most common applications of thermal desalination technologies. The present paper presents a comprehensive thermodynamic model of a 24 million litres per day thermal desalination plant, using specialised software packages. The proposed model was validated against a real data set for a large-scale desalination plant, and showed good agreement. The performance of the MED-TVC unit was investigated using different loads, entrained vapour, seawater temperature, salinity and number of effects in two configurations. The first configuration was the MED-TVC unit without preheating system, and the second integrated the MED-TVC unit with a preheating system. The study confirmed that the thermo-compressor and its effects are the main sources of exergy destruction in these desalination plants, at about 40% and 35% respectively. The desalination plant performance with preheating mode performs well due to high feed water temperature leading to the production of more distillate water. The seawater salinity was proportional to the fuel exergy and minimum separation work. High seawater salinity results in high exergy efficiency, which is not the case with membrane technology. The plant performance of the proposed system was enhanced by using a large number of effects due to greater utilisation of energy input and higher generation level. From an economic perspective, both indicators show that using a preheating system is more economically attractive.

6 March 2019 in Energies
Verified
Journal Article
Open access
PDF file
RLRasaq LAMIDI
Rasaq LAMIDI
LJLong Jiang
Long Jiang
Yaodong WangYaodong Wang
Yaodong Wang
Pankaj B. PatharePankaj B. Pathare
Pankaj B. Pathare
MAMarcelo Calispa Aguilar
Marcelo Calispa Aguilar
ARAnthony Paul Roskilly
Anthony Paul Roskilly
Over 90% of global yam production is from West Africa where it provides food and income for above 300 million smallholders’ farmers. However, the major challenge of yam is 10–40% post-harvest losses due to the lack of appropriate storage facilities. This paper assesses a biogas-driven cogeneration system, which could supply electricity and cold storage for ‘yam bank’ within a rural community. Considering 200 households’ Nigerian village as a case study, crop residues are used as anaerobic digestion feedstock to produce biogas, which is subsequently used to power an internal combustion engine. Result shows that the system could store 3.6 tonnes of yam tubers each year and provide enough electricity for domestic and commercial activities. At the current electricity tariff of USD0.013·kWh−1 for rural areas, the system is unable to payback during its life span. The proposed USD0.42·kWh−1 by Nigerian Rural Electrification Agency seems good with less than 3 years discounted payback period but brings about extra burden on poor rural households. Based on the income from cold storage, electricity tariff of USD0.105·kWh−1 with an interest rate of 4% is suggested to be reasonable which results in 6.84 years discounted payback period especially considering non-monetary benefits of renewable energy system.

1 May 2017 in Energy Procedia
Verified
Journal Article
Open access
RLRasaq LAMIDI
Rasaq LAMIDI
Yaodong WangYaodong Wang
Yaodong Wang
Pankaj B. PatharePankaj B. Pathare
Pankaj B. Pathare
ARA.P. Roskily
A.P. Roskily