The present paper reports the impact of the Covid-19 pandemic on the electricity peak load and power generation in the State of Kuwait during the partial and full curfews imposed in March, April and May 2020 using historic data measured data and the predictions provided by a statistical genetic algorithm model. A quantitative assessment is made of the economic and environmental impacts caused by partial and full lockdowns. Comparison of measured peak demand for 2019 and 2020 with predicted peak demand for 2020 has: (i) enabled an accurate evaluation of residential energy consumption in the state of Kuwait at nearly 18 MWh yearly the highest energy consumption per capita in the world, (ii) shown that the imposition of the curfews to reduce the spread of COVID-19 caused a fall in the demand for electrical power of 17.6% compared with the expected demand and (iii) quantified the reduction in CO2, NOx and CO pollutant emissions produced by power plants due to less fuel being consumed. A mathematical model has been developed to predict the peak electric load in the national grid according to climatic data supplied by the Meteorological Department of Civil Aviation of Kuwait and National Control Center (NCC).
The jet impingement technique is an effective method to achieve a high heat transfer rate and is widely used in industry. Enhancing the heat transfer rate even minimally will improve the performance of many engineering systems and applications. In this numerical study, the convective heat transfer process between orthogonal air jet impingement on a smooth, horizontal surface and a roughened uniformly heated flat plate is studied. The roughness element takes the form of a circular rib of square cross-section positioned at different radii around the stagnation point. At each location, the effect of the roughness element on heat transfer rate was simulated for six different heights and the optimum rib location and rib dimension determined. The average Nusselt number has been evaluated within and beyond the stagnation region to better quantify the heat transfer advantages of ribbed surfaces over smooth surfaces. The results showed both flow and heat transfer features vary significantly with rib dimension and location on the heated surface. This variation in the streamwise direction included both augmentation and decrease in heat transfer rate when compared to the baseline no-rib case. The enhancement in normalized averaged Nusselt number obtained by placing the rib at the most optimum radial location R/D = 2 was 15.6% compared to the baseline case. It was also found that the maximum average Nusselt number for each location was achieved when the rib height was close to the corresponding boundary layer thickness of the smooth surface at the same rib position.
Desalination is the sole proven technique that can provide the necessary fresh water in arid and semi-arid countries in sufficient quantities and meet the modern needs of a growing world population. Multi effect desalination with thermal vapour compression (MED-TVC) is one of most common applications of thermal desalination technologies. The present paper presents a comprehensive thermodynamic model of a 24 million litres per day thermal desalination plant, using specialised software packages. The proposed model was validated against a real data set for a large-scale desalination plant, and showed good agreement. The performance of the MED-TVC unit was investigated using different loads, entrained vapour, seawater temperature, salinity and number of effects in two configurations. The first configuration was the MED-TVC unit without preheating system, and the second integrated the MED-TVC unit with a preheating system. The study confirmed that the thermo-compressor and its effects are the main sources of exergy destruction in these desalination plants, at about 40% and 35% respectively. The desalination plant performance with preheating mode performs well due to high feed water temperature leading to the production of more distillate water. The seawater salinity was proportional to the fuel exergy and minimum separation work. High seawater salinity results in high exergy efficiency, which is not the case with membrane technology. The plant performance of the proposed system was enhanced by using a large number of effects due to greater utilisation of energy input and higher generation level. From an economic perspective, both indicators show that using a preheating system is more economically attractive.
The results of an experimental study to evaluate the characteristics of R-407C thermofluid during condensation in a helically coiled copper tube heat exchanger are presented. The effects of saturation temperature (Tsat), and mass and heat fluxes of refrigerant R-407C on thermal performance and pressure drop were determined. The relationship between the refrigerant wall subcooling and heat transfer coefficients was also investigated. This paper reports the effect of the temperature of the water used as cooling medium on the heat transfer rate of condensing R-407C. The study was conducted with mass flux of R-407C in the range of 100–450 kg/m2s, mass flux of the coolant water in the range of 500–5000 kg/m2s and Tsat of 31 °C, 35 °C, and 39 °C. Compared with a straight smooth tube, the use of the helical coiled (helicoidal) tube increased the condensation rate with a corresponding pressure drop that depended on the value of Tsat of the refrigerant and temperature of the coolant.
6 January 2021 in Journal of Thermal Science and Engineering Applications
A detailed heat transfer numerical study of a three-dimensional impinging jet on a roughened isothermal surface is presented and is investigated from flow physics vantage point under the influence of different parameters. The effects of the Reynolds number, roughness location, and roughness dimension on the flow physics and heat transfer parameters are studied. Additionally, the relations between average heat transfer coefficient (AHTC) and flow physics including pressure, wall shear and flow vortices with thermodynamic nonequilibrium are offered. This paper studies the effect of varying both location and dimension of the roughness element which took the shape of square cross-sectional continuous ribs to deliver a favorable trade-off between total pressure loss and heat transfer rate. The roughness element was tested for three different radial locations (R/D) = 1, 1.5, and 2 and at each location its height (i.e., width) (e) was changed from 0.25 to 1 mm in incremental steps of 0.25. The study used a jet angle (α) of 90 deg, jet-to-target distance (H/D = 6), and Re ranges from 10,000 to 50,000, where H is the vertical distance between the target plate and jet exit. The results show that the AHTC can be significantly affected by changing the geometry and dimensions of the roughness element. This variation can be either an augmentation of, or decrease in, the (HTC) when compared with the baseline case. An enhancement of 12.9% in the AHTC was achieved by using optimal location and dimensions of the roughness element at specific Reynolds number. However, a diminution between 10% and 30% in (AHTC) was attained by the use of rib height e = 1 mm at Re = 50k. The variation of both rib location and height showed better contribution in increasing heat transfer for low-range Reynolds numbers.
The results obtained from the exergoeconomic and exergy analysis of a model of a generic air conditioning (A/C) system without and with an air membrane exchanger using three commercially available refrigerants: R410A, R407C, and R134a, are reported. The model used specialized software that was validated against recently published data and showed good agreement. A/C systems are energy intensive and consume a significant portion of global electricity. Improving their efficiency by even a small amount will produce considerable savings, reduce running costs, and lower pollution emissions. The efficiency of the same A/c system without and with a membrane was investigated for different ambient temperatures, relative humidities (RHs), and pressure ratios of the compressor. It was shown that the inclusion of a membrane improved the efficiency of the system for all three refrigerants tested, particularly at higher ambient temperature. Both the coefficient of performance and exergetic efficiency reduced with the increase in the pressure ratio due to increasing fuel exergy and losses. In all system components except one, it was found that the source of the cost is inefficiencies; hence, increasing the efficiency at the expense of the non-exergy cost will improve the cost effectiveness of the entire system.