Min-Woong Seo

Dr. Min-Woong Seo


Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2016 in Biosensors and Bioelectronics
Verified
Journal Article
Open access
OAOluwasesan Adegoke
Oluwasesan Adegoke
MSMin-Woong Seo
Min-Woong Seo
KTKato Tatsuya
Kato Tatsuya
SKShoji Kawahito
Shoji Kawahito
Enoch Y. ParkEnoch Y. Park
Enoch Y. Park
Ultrasensitive, rapid and selective diagnostic probes are urgently needed to overcome the limitations of traditional probes for norovirus (NV). Here, we report the detection of NV genogroup II via nucleic acid hybridization technology using a quantum dot (QD)-conjugated molecular beacon (MB) probe. To boost the sensitivity of the MB assay system, an ultrasensitive QD fluorophore with unique optical properties was synthesized, characterized and exploited as a fluorescence signal generator. Alloyed thioglycolic (TGA)-capped CdZnSeS QDs with a high photoluminescence (PL) quantum yield (QY) value of 92% were synthesized, and a modified silanization method was employed to encapsulate the thiol-capped QDs in a silica layer. The resulting highly luminescent alloyed SiO2-coated CdZnSeS QDs had a remarkable PL QY value of 98%. Transmission electron microscopy and dynamic light scattering confirmed the monodispersity of the alloyed nanocrystals, and zeta potential analysis confirmed their colloidal stability. Powder X-ray diffraction and PL lifetime measurements confirmed the surface modification of the QDs. The alloyed TGA-capped and SiO2-coated CdZnSeS QD-conjugated MB bioprobes detected extremely low concentrations of NV RNA. Ultrasensitive detection of low concentrations of NV RNA with a limit of detection (LOD) of 8.2copies/mL in human serum and a LOD of 9.3 copies/mL in buffer was achieved using the SiO2-coated CdZnSeS QD-MB probes, an increase in sensitivity of 3-fold compared with the detection limit for NV RNA using TGA-capped CdZnSeS QD-MBs. The additional merits of our detection system are rapidity, specificity and improved sensitivity over conventional molecular test probes.

18 January 2016 in Journal of Materials Chemistry B
Verified
Journal Article
Open access
PDF file
OAOluwasesan Adegoke
Oluwasesan Adegoke
MSMin-Woong Seo
Min-Woong Seo
KTKato Tatsuya
Kato Tatsuya
SKShoji Kawahito
Shoji Kawahito
Enoch Y. ParkEnoch Y. Park
Enoch Y. Park
Controlling and engineering the particle composition of semiconductor alloys is one of the topmost targets in the field of semiconductor materials science and technology. Quantum dot (QD) nanocrystals offer an unmatched opportunity to obtain a wide range of composition-controlled alloys and have captivated a great deal of interest recently. Herein, we report on band gap engineering via tuning and controlling the sulphur molar fraction (ternary shell layer) of quaternary/ternary core/shell alloyed CdZnSeS/ZnSeS QDs. Varying optical properties were exhibited by the alloyed QDs but a uniform particle size distribution was maintained across all the compositions. The alloyed QDs displayed bright emission colours under UV irradiation, whereas the photoluminescence quantum yields (PL QY) were in a remarkable range of 36–98%. Non-linearity of the lattice parameter was an indication of gradient alloying of the nanocrystals, whereas the kinetics of the optical properties unravelled the effect of intrinsic optical bowing. Displacement of bond length and anion mismatch influenced the optical properties of the QDs with respect to the variation in the PL QY. Alloyed CdZnSeS/ZnSe1.0S1.3 QDs with a spectacular PL QY were exploited as an ultrasensitive fluorescence reporter in a conjugated molecular beacon (MB) assay to detect influenza virus H1N1 RNA. Our detection system was rapid and highly sensitive for detecting extremely low concentrations of H1N1 RNA (down to 2 copies per mL), specific and versatile (detects H1N1 RNA in human serum). For proof of concept, the alloyed CdZnSeS/ZnSe1.0S1.3 QD-MB bioprobe exhibited a superior 12-fold sensitivity over an alloyed CdZnSeS-MB probe, while a conventional CdSe/ZnS-MB probe could not detect extremely low concentrations of influenza virus H1N1 RNA.

6 November 2016 in Sensors
Verified
Journal Article
Open access
PDF file
SKShoji Kawahito
Shoji Kawahito
MSMin-Woong Seo
Min-Woong Seo
This paper discusses the noise reduction effect of multiple-sampling-based signal readout circuits for implementing ultra-low-noise image sensors. The correlated multiple sampling (CMS) technique has recently become an important technology for high-gain column readout circuits in low-noise CMOS image sensors (CISs). This paper reveals how the column CMS circuits, together with a pixel having a high-conversion-gain charge detector and low-noise transistor, realizes deep sub-electron read noise levels based on the analysis of noise components in the signal readout chain from a pixel to the column analog-to-digital converter (ADC). The noise measurement results of experimental CISs are compared with the noise analysis and the effect of noise reduction to the sampling number is discussed at the deep sub-electron level. Images taken with three CMS gains of two, 16, and 128 show distinct advantage of image contrast for the gain of 128 (noise(median): 0.29 e−rms) when compared with the CMS gain of two (2.4 e−rms), or 16 (1.1 e−rms).

16 January 2014 in Sensors
Verified
Journal Article
Open access
PDF file
BZBo Zhang
Bo Zhang
KKKeiichiro Kagawa
Keiichiro Kagawa
TTTaishi Takasawa
Taishi Takasawa
MSMin-Woong Seo
Min-Woong Seo
KYKeita Yasutomi
Keita Yasutomi
SKShoji Kawahito
Shoji Kawahito
In extremely low-light conditions, random telegraph signal (RTS) noise and dark current white defects become visible. In this paper, a multi-aperture imaging system and selective averaging method which removes the RTS noise and the dark current white defects by minimizing the synthetic sensor noise at every pixel is proposed. In the multi-aperture imaging system, a very small synthetic F-number which is much smaller than 1.0 is achieved by increasing optical gain with multiple lenses. It is verified by simulation that the effective noise normalized by optical gain in the peak of noise histogram is reduced from 1.38e⁻ to 0.48 e⁻ in a 3 × 3-aperture system using low-noise CMOS image sensors based on folding-integration and cyclic column ADCs. In the experiment, a prototype 3 × 3-aperture camera, where each aperture has 200 × 200 pixels and an imaging lens with a focal length of 3.0 mm and F-number of 3.0, is developed. Under a low-light condition, in which the maximum average signal is 11e⁻ per aperture, the RTS and dark current white defects are removed and the peak signal-to-noise ratio (PSNR) of the image is increased by 6.3 dB.

30 June 2019 in Sensors
Verified
Journal Article
Open access
PDF file
MLMinho Lee
Minho Lee
MSMin-Woong Seo
Min-Woong Seo
JKJuyeong Kim
Juyeong Kim
KYKeita Yasutomi
Keita Yasutomi
KKKeiichiro Kagawa
Keiichiro Kagawa
SKShoji Kawahito
Shoji Kawahito
In this paper, a wide dynamic range (WDR) CMOS image sensor (CIS) with a charge splitting gate (SG) and two storage diodes (SDs) is presented. By using single-gate on/off control with the SG, photocurrent path to the first (SD1) or second storage diodes (SD2) is switched alternatively and periodically during exposure and signal electrons generated in a photodiode (PD) are transferred to and accumulated in the SD1 or SD2. By setting a large ratio of the off-time to on-time of the SG, two different sensitivity signals, which are originated by the same photodiode, are generated and a WDR image signal is obtained. This technique has a distinct advantage on mitigating the problem of motion artifact in WDR imaging with high and low sensitivity signals and flexible dynamic control of the dynamic range. An experimental WDR CMOS image sensor with 280 (H) × 406 (V)-pixel array consisting of 14 sub-arrays, each of which have 20 (H) × 406 (V) pixels, was implemented and tested. For the SG on/off-time ratio of 30 and 279, the DR of 93 dB and 104 dB, respectively, was demonstrated. The effect of the proposed WDR imaging operation on the reduced motion artifact was experimentally confirmed.

2 September 2015 in BMC Gastroenterology
Verified
Journal Article
Open access
PDF file
YKYoko Kominami
Yoko Kominami
SYShigeto Yoshida
Shigeto Yoshida
Shinji TanakaShinji Tanaka
Shinji Tanaka
RMRie Miyaki
Rie Miyaki
YSYoji Sanomura
Yoji Sanomura
KCKazuaki Chayama
Kazuaki Chayama
It is important to devise efficient and easy methods of detecting colorectal tumours to reduce mortality from colorectal cancer. Dual-wavelength excitation autofluorescence intensity can be used to visualize colorectal tumours. Therefore, we evaluated dual-wavelength excitation autofluorescence images of colorectal tumours obtained with a newly developed, high-sensitivity complementary metal-oxide-semiconductor (CMOS) imager. A total 107 colorectal tumours (44 adenomas, 43 adenocarcinomas with intramucosal invasion, and 20 sessile serrated adenoma/polyps [SSA/Ps]) in 98 patients who underwent endoscopic tumour resection were included. The specimens were irradiated with excitation light at 365 nm and 405 nm, and autofluorescence images measured with a 475 ± 25-nm band pass filter were obtained using a new, high-sensitivity CMOS imager. Ratio images (F365ex/F405ex) were created to evaluate the lesion brightness compared with that of normal mucosa, and specimens were categorized into a no signal or high signal group. Adenomas and adenocarcinomas were depicted in 87 ratio images, with 86.2 % (n = 75) in the High signal group. SSA/P was depicted in 20 ratio images, with 70.0 % (n = 14) in the High signal group. Dual-wavelength excitation autofluorescence images of colorectal tumours can be acquired using our high-sensitivity CMOS imager, and are useful in detecting colorectal tumours.