Yuan Meng

Dr. Yuan Meng

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 January 2016 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
YMYuan Meng
Yuan Meng
RDRobert Neal Dean
Robert Neal Dean
One technique for measuring an unknown sensor capacitance is using the phase delay of an RC network with a resistor and the sensor capacitor. By buffering the RC network with CMOS inverters, a square wave signal can be delayed through the circuit in proportion to the unknown capacitance. An EXOR gate can be used to compare the delayed square wave with a reference square wave to produce a pulsewidth-modulated signal where the pulsewidth is proportional to the unknown capacitance. This technique has a nearly linear response when the phase delay is small compared with the period of the square wave. However, this technique becomes severely nonlinear if the phase delay is larger than approximately one eighth of the period (45°), as the capacitor does not get fully charged or discharged every half period. To mitigate this nonlinearity, a novel resistance switching RC phase delay network is used to expand the linear range of the phase delay by accelerating the charging and discharging processes of the sensor capacitor. This approach is demonstrated using a fringing field capacitive sensor to measure the mass of added water and expands the linear operation to a phase delay to 133.56°.

1 June 2019 in AEU - International Journal of Electronics and Communications
Verified
Journal Article
Closed access
JPJ. Craig Prather
J. Craig Prather
YMYuan Meng
Yuan Meng
MBMichael Bolt
Michael Bolt
THTyler Horton
Tyler Horton
MAMark Adams
Mark Adams

1 October 2019 in Sensors and Actuators A: Physical
Verified
Journal Article
Closed access
YWYixuan Wu
Yixuan Wu
YMYuan Meng
Yuan Meng
BYBaha Yakupoglu
Baha Yakupoglu
MAMark Adams
Mark Adams

15 November 2019 in Measurement Science and Technology
Verified
Journal Article
Closed access
PDF file
YMYuan Meng
Yuan Meng
RDRobert N. Dean
Robert N. Dean
MAMark L. Adams
Mark L. Adams
Measuring the phase delay of an RC network with a known resistance and an unknown capacitance is a simple technique to determine the value of capacitance. In this technique, the state of an input square wave signal is buffered by CMOS inverters and delayed by an RC network which yields a pulse width modulated (PWM) signal according to the phase delay at the output. The duty cycle of the PWM signal is proportional to the unknown capacitance when the resistance is fixed. However, the response of this method becomes severely nonlinear if the phase delay is larger than approximately 45° due to incomplete charging and discharging processes of the unknown capacitor. A novel MOSFET interface circuit with a PMOS FET to charge the unknown capacitor and an NMOS FET to discharge it during each measurement cycle is presented. This method, which expands the range of linear operation, is demonstrated in simulation and experimentally validated using a fringing field capacitive sensor to measure the mass of added water. The novel circuit expands the linear operation to a phase delay of 140.04°, over which the R 2 value achieves 0.9989.

29 November 2017 in IEEE Transactions on Biomedical Circuits and Systems
Verified
Journal Article
Closed access
YMYuan Meng
Yuan Meng
BBBrent Bottenfield
Brent Bottenfield
MBMark Bolding
Mark Bolding
LLLei Liu
Lei Liu
Mark AdamsMark Adams
Mark Adams
The eye may act as a surrogate for the brain in response to head acceleration during an impact. Passive eye movements in a dynamic system are sensed by microelectromechanical systems (MEMS) inertial measurement units (IMU) in this paper. The technique is validated using a three-dimensional printed scaled human skull model and on human volunteers by performing drop-and-impact experiments with ribbon-style flexible printed circuit board IMUs inserted in the eyes and reference IMUs on the heads. Data are captured by a microcontroller unit and processed using data fusion. Displacements are thus estimated and match the measured parameters. Relative accelerations and displacements of the eye to the head are computed indicating the influence of the concussion causing impacts.

1 March 2020 in Physiological Measurement
Verified
Journal Article
Closed access
PDF file
YMYuan Meng
Yuan Meng
SMSamuel Mabry
Samuel Mabry
PSPaul Stewart
Paul Stewart
KCKelli Cannon
Kelli Cannon
LLLei Liu
Lei Liu
Mark AdamsMark Adams
Mark Adams
Objective: The eye may act as a surrogate for the brain in response to head acceleration during an impact. This paper reports the latest demonstration of the correlation between the passive human eye accelerations and the brain accelerations under head impacts using a model eye/brain/skull phantom. Approach: Experiments investigating rotational and linear accelerations were performed on a 3D-printed human head phantom, along with rotational experiments on a human volunteer. Data acquired during the passive eye response (PER) periods were processed and analysed using statistical methods including one-way normal analysis of variance, linear regression fit, and Pearson R correlation. Main results: The results have shown that, at least on the 3D-printed human head phantom, strong correlations can be found between the eye and the brain during the PER, which indicates a potential use of microelectromechanical systems inertial measurement units in real-time on-field monitoring and diagnosis of concussions or traumatic brain injuries. Significance: These discoveries pave the way for potential non-invasive wearable devices based on this technology to be applied in real-time on-field concussion monitoring, which is expected to provide vulnerable parties with instant alert thus timely treatment.