Cameron Kaye

Dr. Cameron Kaye

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 July 2019 in IEEE Transactions on Antennas and Propagation
Verified
Journal Article
Closed access
CKCameron Kaye
Cameron Kaye
IJIan Jeffrey
Ian Jeffrey
JLJoe LoVetri
Joe LoVetri
Two modifications of the Contrast Source Inversion algorithm (CSI) have been employed to improve resulting 2D microwave images of the dielectric properties of synthetic breast models produced using a well-established frequency-hopping technique. First, while reconstructions from low-frequency data are often used as initial guesses for otherwise unstable higher-frequency inversions, an improvement in overall image quality can be observed when the imaginary part of the reconstructed low-frequency image is altered to reflect the identical tissue geometry as its real part when used as an initial guess during subsequent reconstructions. Secondly, in such frequency-hopping scenarios, rather than terminating reconstructions following inversions of the highest frequency data“, frequency cycling” (i.e. returning to the lowest frequency in the sequence) can be used to further improve reconstructions without loss of resolution or anatomical detail.

26 August 2020 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
CKCameron Kaye
Cameron Kaye
Colin GilmoreColin Gilmore
Colin Gilmore
JLJoe LoVetri
Joe LoVetri
Objective: An aluminium faceted chamber designed for 3D microwave imaging (MWI) of the breast has been integrated into an electromagnet in order to carry out signal acquisition experiments for an inverse scattering-based ferromagnetic resonance imaging (FRI) system, or magnetic contrast-enhanced MWI system. Methods: For this proof of concept, the chamber has been equipped with four wire monopole antennas, and low-contrast oil-based targets have been tested with varying concentrations of iron oxide magnetic nanoparticles (MNP) to serve as ferromagnetic contrast agents. The electromagnet is capable of sustaining a static polarizing magnetic field (PMF) greater than 0.2 Tesla (2000 Gauss) across the imaging chamber to modulate the MNPs' ferromagnetic response, effectively changing the targets' magnetic permeability. Differential scattered field data are then collected through the application and withdrawal of this PMF. Results: This study has successfully characterized a particular narrow band of frequencies within the asymmetric faceted chamber that demonstrate significant differential responses corresponding to the weak magnetic signal physically isolated from the MNPs, tested on different sizes and positions of targets containing various concentrations of MNPs. Conclusion: Similar to ferromagnetic resonance (FMR) spectroscopy, in which detection of FMR phenomena is best achieved at probing frequencies coinciding with the structural resonant frequency of a metallic cavity, these resonant frequencies of interest yield a high level of sensitivity to MNP permeability changes and are suitable for imaging within the chamber. Significance: These represent the first experimental results of a full-scale FRI system capable of detecting and eventually imaging MNPs at biologically relevant concentrations.

22 May 2019 in Journal of Imaging
Verified
Journal Article
Open access
PDF file
CKCameron Kaye
Cameron Kaye
IJIan Jeffrey
Ian Jeffrey
JLJoe LoVetri
Joe LoVetri
A discontinuous Galerkin formulation of the Contrast Source Inversion algorithm (DGM-CSI) for microwave breast imaging employing a frequency-cycling reconstruction technique has been modified here to include a set of automated stopping criteria that determine a suitable time to shift imaging frequencies and to globally terminate the reconstruction. Recent studies have explored the use of tissue-dependent geometrical mapping of the well-reconstructed real part to its imaginary part as initial guesses during consecutive frequency hops. This practice was shown to improve resulting 2D images of the dielectric properties of synthetic breast models, but a fixed number of iterations was used to halt DGM-CSI inversions arbitrarily. Herein, a new set of stopping conditions is introduced based on an intelligent statistical analysis of a window of past iterations of data error using the two-sample Kolmogorov-Smirnov (K-S) test. This non-parametric goodness-of-fit test establishes a pattern in the data error distribution, indicating an appropriate time to shift frequencies, or terminate the algorithm. The proposed stopping criteria are shown to improve the efficiency of DGM-CSI while yielding images of equivalent quality to assigning an often liberally overestimated number of iterations per reconstruction.