N. Evelin Paucar

Ms. N. Evelin Paucar

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 January 2021 in Environmental Chemistry Letters
Verified
Journal Article
Closed access
PDF file
NPN. Evelin Paucar
N. Evelin Paucar
PKPeyton Kiggins
Peyton Kiggins
BBBryson Blad
Bryson Blad
KJKarl De Jesus
Karl De Jesus
FAFarjana Afrin
Farjana Afrin
Kumari SharmaKumari Sharma
Kumari Sharma

14 June 2018 in Ozone: Science & Engineering
Verified
Journal Article
Closed access
NPN. Evelin Paucar
N. Evelin Paucar
IKIlho Kim
Ilho Kim
HTHiroaki Tanaka
Hiroaki Tanaka
CSChikashi Sato
Chikashi Sato
This study investigated the degradability of pharmaceuticals and personal care products (PPCPs) by ozonation for the treatment of secondary effluent of a municipal wastewater treatment plant. A set of experiments were conducted in a laboratory using a pilot-scale process consisting of three flow-through reactors in series, by varying the ozone dose (1–9 mg L−1), the hydraulic retention time (5–15 min), and the concentration of ozone injected into the reactors (14–42 mg L−1). Thirty-seven PPCPs were detected in the secondary effluent, which belongs to the use categories of antibiotics, analgesics, antiarrhythmic agents, anticonvulsants, vasodilators, lipid modifying agents, anti-itch drugs, anti-psychotic drugs, insect repellents, bronchodilators, diuretics, peptic ulcer drugs, NMDA receptor antagonists, antifungal drugs, antimicrobial drugs, and antineoplastic agents. These PPCPs were broadly classified into five groups ranging from “sensitive” to ozone (O3) or “unstable” in the ozonation process, to the group of “insensitive” to O3 or “very stable” in the ozonation process. These groups are based on the PPCP concentrations after the ozone treatment and their limit of detection (LOD). Furthermore, this study examined comparatively the effects of the ozone dose, the retention (reaction) time, and the concentration of O3 supplied to the reactors on the degradability of the PPCPs.

29 July 2021 in Processes
Verified
Journal Article
Open access
PDF file
NPN. Evelin Paucar
N. Evelin Paucar
Chikashi SatoChikashi Sato
Chikashi Sato
The world is facing serious threats from the depletion of non-renewable energy resources, freshwater shortages and food scarcity. As the world population grows, the demand for fresh water, energy, and food will increase, and the need for treating and recycling wastewater will rise. In the past decade, wastewater has been recognized as a resource as it primarily consists of water, energy-latent organics and nutrients. Microbial fuel cells (MFC) have attracted considerable attention due to their versatility in their applications in wastewater treatment, power generation, toxic pollutant removal, environmental monitoring sensors, and more. This article provides a review of MFC technologies applied to the removal and/or recovery of nutrients (such as P and N), organics (COD), and bioenergy (as electricity) from various wastewaters. This review aims to provide the current perspective on MFCs, focusing on the recent advancements in the areas of nutrient removal and/or recovery with simultaneous power generation.

19 September 2022 in Energies
Verified
Journal Article
Open access
PDF file
NPN. Evelin Paucar
N. Evelin Paucar
Chikashi SatoChikashi Sato
Chikashi Sato
Water, energy, and food are indispensable for sustainable economic development. Despite nutrients, especially phosphorus and nitrogen, being essential for plant growth and thus food supplies, those present in wastewater are considered an environmental burden. While microbial fuel cells (MFCs) are receiving much interest, combining wastewater treatment with an MFC has emerged as an option for low-cost wastewater treatment. Among others, a constructed wetland (CW) coupled with an MFC (CW-MFC) has the potential to provide a low carbon footprint and low-energy wastewater treatment, as well as nutrient and energy recovery from wastewater. Findings from this review show that the organic and nutrient removal and power generation by the integrated CW-MFC systems are affected by a number of factors including the organic loading rate, hydraulic retention time, system design, plant species, dissolved oxygen, substrate/media type, influent feeding mode, electrode materials and spacing, and external resistance. This review aims to summarize the current state of the CW-MFC and related technologies with particular emphasis on organic and nutrient removal, as well as on the bioenergy recovery from different wastewaters. Despite the benefits that these technologies can offer, the interactive mechanisms between the CW and MFC in the integrated system are still unclear. Further research is needed to fully understand the CW-MFC and related systems. The results of this work provide not only an overview and insight into existing knowledge but also the future direction of the CW-MFC technologies.

13 March 2025 in Resources
Verified
Journal Article
Open access
PDF file
Wilgince ApollonWilgince Apollon
Wilgince Apollon
IRIryna Rusyn
Iryna Rusyn
NPN. Evelin Paucar
N. Evelin Paucar
MHMonte Hibbert
Monte Hibbert
Sathish Kumar KamarajSathish Kumar Kamaraj
Sathish Kumar Kamaraj
Chikashi SatoChikashi Sato
Chikashi Sato
Microbial fuel cells (MFCs) are environmentally friendly energy converters that use electrochemically active bacteria (EAB) as catalysts to break down organic matter while producing bioelectricity. Traditionally, MFC research has relied on simple organic substrates, such as acetate, glucose, sucrose, butyrate, and glutamate, the production of which involves energy-intensive, CO2-dependent processes and chemically aggressive methods. In contrast, nonconventional waste streams offer a more sustainable alternative as feedstocks, aligning with zero-waste and regenerative agricultural principles. This review highlights the potential of nonconventional organic wastes, such as fruit and vegetable wastes, raw human and livestock urine, and farm manure, as globally available and low-cost substrates for MFCs, particularly in household and farming applications at small-scale waste levels. Furthermore, complex waste sources, including hydrocarbon-contaminated effluents and lignin-rich industrial wood waste, which present unique challenges and opportunities for their integration into MFC systems, were examined in depth. The findings of this review reveal that MFCs utilizing nonconventional substrates can achieve power outputs comparable to traditional substrates (e.g., 8314 mW m−2–25,195 mW m−2 for crude sugarcane effluent and raw distillery effluent, respectively) and even superior to them, reaching up to 88,990 mW m−2 in MFCs utilizing vegetable waste. Additionally, MFCs utilizing hydrocarbon-containing petroleum sediment achieved one of the highest reported maximum power densities of 50,570 mW m−2. By integrating diverse organic waste streams, MFCs can contribute to carbon-neutral energy generation and sustainable waste management practices.

1 June 2019 in Chemengineering
Verified
Journal Article
Open access
PDF file
NPN. Evelin Paucar
N. Evelin Paucar
IKIiho Kim
Iiho Kim
HTHiroaki Tanaka
Hiroaki Tanaka
Chikashi SatoChikashi Sato
Chikashi Sato
A municipal wastewater treatment plant (WWTP) is a melting pot of numerous pharmaceuticals and personal care products (PPCPs) together with many other substances. The removal of PPCPs using advanced oxidation processes within a WWTP is one way to reduce the amount of PPCPs that potentially enter an aquatic environment. The aim of this study was to examine the effectiveness of the ozone (O3)/UV treatment process, especially, the effects of O3 dose and reaction time, on the removal of PPCPs in the secondary effluent of a WWTP. Experiments were conducted using a pilot-scale treatment process that consisted of two flow-through reactors connected in series. Each reactor was equipped with three 65 W lamps (UV65W). The experimental variables were ozone dosage (1, 2, 3, 4, and 6 mg L−1) and hydraulic retention time (HRT; 5 and 10 min). On the basis of the PPCP concentrations after O3/UV65W treatment and their limit of detection (LOD), 38 PPCPs detected in the secondary effluent were classified into 5 groups ranging from the category of “sensitive” to O3/UV65W or “unstable” in the O3/UV65W process to the category of “insensitive” to O3/UV65W or “very stable” in the O3/UV65W process.