Sophie Voisin

Sophie Voisin

orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2013 in Journal of the American Medical Informatics Association
Verified
Journal Article
Open access
PDF file
GTGeorgia Tourassi
Georgia Tourassi
SVSophie Voisin
Sophie Voisin
VPVincent Paquit
Vincent Paquit
EKElizabeth Krupinski
Elizabeth Krupinski
Objective To investigate machine learning for linking image content, human perception, cognition, and error in the diagnostic interpretation of mammog

22 March 2012 in The Journal of Physical Chemistry C
Verified
Journal Article
Closed access
JNJagjit Nanda
Jagjit Nanda
HBHassina Bilheux
Hassina Bilheux
SVSophie Voisin
Sophie Voisin
GVGabriel M. Veith
Gabriel M. Veith
RARick Archibald
Rick Archibald
SPSreekanth Pannala
Sreekanth Pannala

17 January 2013 in Plant and Soil
Verified
Journal Article
Closed access
PDF file
JWJeffrey Warren
Jeffrey Warren
HBHassina Bilheux
Hassina Bilheux
MKMisun Kang
Misun Kang
SVSophie Voisin
Sophie Voisin
CCChu-Lin Cheng
Chu-Lin Cheng
EPEdmund Perfect
Edmund Perfect

11 September 2013 in Medical Physics
Verified
Journal Article
Closed access
SVSophie Voisin
Sophie Voisin
FPFrank Pinto
Frank Pinto
GMGarnetta Morin‐Ducote
Garnetta Morin‐Ducote
KHKathleen B. Hudson
Kathleen B. Hudson
GTGeorgia D. Tourassi
Georgia D. Tourassi

1 March 2007 in Optical Engineering
Verified
Journal Article
Open access
PDF file
SVSophie Voisin
Sophie Voisin
SFSebti Foufou
Sebti Foufou
FTFrédéric Truchetet
Frédéric Truchetet
DPDavid L. Page
David L. Page
MAMongi A. Abidi
Mongi A. Abidi
Three-dimensional (3D) scanners are used in more and more applications, and range accuracy is the main challenge for manufacturers. The knowledge of this accuracy helps to better exploit the results and the information from the scanners. Usually when the manufacturer does not provide enough information, the user has to characterize the scanner before using it. This letter describes some preliminary results we have obtained during the characterization of a commercial 3D scanner based on structured light.1 More precisely, we will focus on the study of range accuracy with respect to an illuminant that our reproducible experimental setup has provided.

10 May 2013 in Physical Chemistry Chemical Physics
Verified
Journal Article
Closed access
PDF file
KSKetki Sharma
Ketki Sharma
HBHassina Bilheux
Hassina Bilheux
LWLakeisha M. H. Walker
Lakeisha M. H. Walker
SVSophie Voisin
Sophie Voisin
RMRichard Mayes
Richard Mayes
CTCostas Tsouris
Costas Tsouris
Neutron imaging is presented as a tool for quantifying the diffusion of ions inside porous materials, such as carbon electrodes used in the desalination process via capacitive deionization and in electrochemical energy-storage devices. Monolithic mesoporous carbon electrodes of ∼10 nm pore size were synthesized based on a soft-template method. The electrodes were used with an aqueous solution of gadolinium nitrate in an electrochemical flow-through cell designed for neutron imaging studies. Sequences of neutron images were obtained under various conditions of applied potential between the electrodes. The images revealed information on the direction and magnitude of ion transport within the electrodes. From the time-dependent concentration profiles inside the electrodes, the average value of the effective diffusion coefficient for gadolinium ions was estimated to be 2.09 ± 0.17 × 10−11 m2 s−1 at 0 V and 1.42 ± 0.06 × 10−10 m2 s−1 at 1.2 V. The values of the effective diffusion coefficient obtained from neutron imaging experiments can be used to evaluate model predictions of the ion transport rate in capacitive deionization and electrochemical energy-storage devices.