Roberto Romero-Oraá

Mr. Roberto Romero-Oraá

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 April 2024 in Computer Methods and Programs in Biomedicine
Verified
Journal Article
Open access
RRRoberto Romero-Oraá
Roberto Romero-Oraá
María Herrero-TudelaMaría Herrero-Tudela
María Herrero-Tudela
MLMaría I. López
María I. López
Roberto HorneroRoberto Hornero
Roberto Hornero
MGMaría García
María García
Early detection and grading of Diabetic Retinopathy (DR) is essential to determine an adequate treatment and prevent severe vision loss. However, the manual analysis of fundus images is time consuming and DR screening programs are challenged by the availability of human graders. Current automatic approaches for DR grading attempt the joint detection of all signs at the same time. However, the classification can be optimized if red lesions and bright lesions are independently processed since the task gets divided and simplified. Furthermore, clinicians would greatly benefit from explainable artificial intelligence (XAI) to support the automatic model predictions, especially when the type of lesion is specified. As a novelty, we propose an end-to-end deep learning framework for automatic DR grading (5 severity degrees) based on separating the attention of the dark structures from the bright structures of the retina. As the main contribution, this approach allowed us to generate independent interpretable attention maps for red lesions, such as microaneurysms and hemorrhages, and bright lesions, such as hard exudates, while using image-level labels only. Our approach is based on a novel attention mechanism which focuses separately on the dark and the bright structures of the retina by performing a previous image decomposition. This mechanism can be seen as a XAI approach which generates independent attention maps for red lesions and bright lesions. The framework includes an image quality assessment stage and deep learning-related techniques, such as data augmentation, transfer learning and fine-tuning. We used the architecture Xception as a feature extractor and the focal loss function to deal with data imbalance. The Kaggle DR detection dataset was used for method development and validation. The proposed approach achieved 83.7 % accuracy and a Quadratic Weighted Kappa of 0.78 to classify DR among 5 severity degrees, which outperforms several state-of-the-art approaches. Nevertheless, the main result of this work is the generated attention maps, which reveal the pathological regions on the image distinguishing the red lesions and the bright lesions. These maps provide explainability to the model predictions. Our results suggest that our framework is effective to automatically grade DR. The separate attention approach has proven useful for optimizing the classification. On top of that, the obtained attention maps facilitate visual interpretation for clinicians. Therefore, the proposed method could be a diagnostic aid for the early detection and grading of DR.

18 December 2024 in Biomedical Signal Processing and Control
Verified
Journal Article
Open access
María Herrero-TudelaMaría Herrero-Tudela
María Herrero-Tudela
RRRoberto Romero-Oraá
Roberto Romero-Oraá
Roberto HorneroRoberto Hornero
Roberto Hornero
Gonzalo Gutiérrez-TobalGonzalo Gutiérrez-Tobal
Gonzalo Gutiérrez-Tobal
MLMaribel Lopez
Maribel Lopez
MGMaría García
María García

16 November 2020 in Sensors
Verified
Journal Article
Open access
PDF file
RRRoberto Romero-Oraá
Roberto Romero-Oraá
MGMaría García
María García
JOJavier Oraá-Pérez
Javier Oraá-Pérez
MLMaribel Lopez
Maribel Lopez
Roberto HorneroRoberto Hornero
Roberto Hornero
Diabetic retinopathy (DR) is characterized by the presence of red lesions (RLs), such as microaneurysms and hemorrhages, and bright lesions, such as exudates (EXs). Early DR diagnosis is paramount to prevent serious sight damage. Computer-assisted diagnostic systems are based on the detection of those lesions through the analysis of fundus images. In this paper, a novel method is proposed for the automatic detection of RLs and EXs. As the main contribution, the fundus image was decomposed into various layers, including the lesion candidates, the reflective features of the retina, and the choroidal vasculature visible in tigroid retinas. We used a proprietary database containing 564 images, randomly divided into a training set and a test set, and the public database DiaretDB1 to verify the robustness of the algorithm. Lesion detection results were computed per pixel and per image. Using the proprietary database, 88.34% per-image accuracy (ACCi), 91.07% per-pixel positive predictive value (PPVp), and 85.25% per-pixel sensitivity (SEp) were reached for the detection of RLs. Using the public database, 90.16% ACCi, 96.26% PPV_p, and 84.79% SEp were obtained. As for the detection of EXs, 95.41% ACCi, 96.01% PPV_p, and 89.42% SE_p were reached with the proprietary database. Using the public database, 91.80% ACCi, 98.59% PPVp, and 91.65% SEp were obtained. The proposed method could be useful to aid in the diagnosis of DR, reducing the workload of specialists and improving the attention to diabetic patients.

19 April 2019 in Entropy
Verified
Journal Article
Open access
PDF file
RRRoberto Romero-Oraá
Roberto Romero-Oraá
JJJorge Jiménez-García
Jorge Jiménez-García
MGMaría García
María García
MLMaribel Lopez
Maribel Lopez
JOJavier Oraá-Pérez
Javier Oraá-Pérez
Roberto HorneroRoberto Hornero
Roberto Hornero
Diabetic retinopathy (DR) is the main cause of blindness in the working-age population in developed countries. Digital color fundus images can be analyzed to detect lesions for large-scale screening. Thereby, automated systems can be helpful in the diagnosis of this disease. The aim of this study was to develop a method to automatically detect red lesions (RLs) in retinal images, including hemorrhages and microaneurysms. These signs are the earliest indicators of DR. Firstly, we performed a novel preprocessing stage to normalize the inter-image and intra-image appearance and enhance the retinal structures. Secondly, the Entropy Rate Superpixel method was used to segment the potential RL candidates. Then, we reduced superpixel candidates by combining inaccurately fragmented regions within structures. Finally, we classified the superpixels using a multilayer perceptron neural network. The used database contained 564 fundus images. The DB was randomly divided into a training set and a test set. Results on the test set were measured using two different criteria. With a pixel-based criterion, we obtained a sensitivity of 81.43% and a positive predictive value of 86.59%. Using an image-based criterion, we reached 84.04% sensitivity, 85.00% specificity and 84.45% accuracy. The algorithm was also evaluated on the DiaretDB1 database. The proposed method could help specialists in the detection of RLs in diabetic patients.

19 January 2025 in Cancers
Verified
Journal Article
Open access
PDF file
Santiago CepedaSantiago Cepeda
Santiago Cepeda
OEOlga Esteban
Olga Esteban
VSVikas Singh
Vikas Singh
PSPrakash Shetty
Prakash Shetty
AMAliasgar Moiyadi
Aliasgar Moiyadi
RSRosario Sarabia
Rosario Sarabia
Background: Intraoperative ultrasound (ioUS) provides real-time imaging during neurosurgical procedures, with advantages such as portability and cost-effectiveness. Accurate tumor segmentation has the potential to substantially enhance the interpretability of ioUS images; however, its implementation is limited by persistent challenges, including noise, artifacts, and anatomical variability. This study aims to develop a convolutional neural network (CNN) model for glioma segmentation in ioUS images via a multicenter dataset. Methods: We retrospectively collected data from the BraTioUS and ReMIND datasets, including histologically confirmed gliomas with high-quality B-mode images. For each patient, the tumor was manually segmented on the 2D slice with its largest diameter. A CNN was trained using the nnU-Net framework. The dataset was stratified by center and divided into training (70%) and testing (30%) subsets, with external validation performed on two independent cohorts: the RESECT-SEG database and the Imperial College NHS Trust London cohort. Performance was evaluated using metrics such as the Dice similarity coefficient (DSC), average symmetric surface distance (ASSD), and 95th percentile Hausdorff distance (HD95). Results: The training cohort consisted of 197 subjects, 56 of whom were in the hold-out testing set and 53 in the external validation cohort. In the hold-out testing set, the model achieved a median DSC of 0.90, ASSD of 8.51, and HD95 of 29.08. On external validation, the model achieved a DSC of 0.65, ASSD of 14.14, and HD95 of 44.02 on the RESECT-SEG database and a DSC of 0.93, ASSD of 8.58, and HD95 of 28.81 on the Imperial-NHS cohort. Conclusions: This study supports the feasibility of CNN-based glioma segmentation in ioUS across multiple centers. Future work should enhance segmentation detail and explore real-time clinical implementation, potentially expanding ioUS’s role in neurosurgical resection.

21 March 2019 in Entropy
Verified
Journal Article
Open access
PDF file
JJJorge Jiménez-García
Jorge Jiménez-García
RRRoberto Romero-Oraá
Roberto Romero-Oraá
MGMaría García
María García
MLMaribel Lopez
Maribel Lopez
Roberto HorneroRoberto Hornero
Roberto Hornero
Diabetic retinopathy (DR) is one of the most common causes of visual loss in developed countries. Computer-aided diagnosis systems aimed at detecting DR can reduce the workload of ophthalmologists in screening programs. Nevertheless, a large number of retinal images cannot be analyzed by physicians and automatic methods due to poor quality. Automatic retinal image quality assessment (RIQA) is needed before image analysis. The purpose of this study was to combine novel generic quality features to develop a RIQA method. Several features were calculated from retinal images to achieve this goal. Features derived from the spatial and spectral entropy-based quality (SSEQ) and the natural images quality evaluator (NIQE) methods were extracted. They were combined with novel sharpness and luminosity measures based on the continuous wavelet transform (CWT) and the hue saturation value (HSV) color model, respectively. A subset of non-redundant features was selected using the fast correlation-based filter (FCBF) method. Subsequently, a multilayer perceptron (MLP) neural network was used to obtain the quality of images from the selected features. Classification results achieved 91.46% accuracy, 92.04% sensitivity, and 87.92% specificity. Results suggest that the proposed RIQA method could be applied in a more general computer-aided diagnosis system aimed at detecting a variety of retinal pathologies such as DR and age-related macular degeneration.