Jaan Ojarand

Dr. Jaan Ojarand

orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 May 2014 in Physiological Measurement
Verified
Journal Article
Closed access
JOJaan Ojarand
Jaan Ojarand
MMMart Min
Mart Min
PAPaul Annus
Paul Annus
The multisine excitation is widely used in impedance measurements to retain the advantages of the sine wave, while reducing the measurement time. Adding up sine waves increases the amplitude of the excitation signal, but, for the linearity assumption to be valid, the overall amplitude of the signal needs to be kept low. Thus, the crest factor (CF) of the excitation signal must be minimized. A novel empirical method for the minimization of the CF is described in this paper. As in the case of other known methods, the computed CF may be guaranteed to be only a local minimum. However, a systematic variation of initial parameters, which is possible due to the sparing algorithm, ensures a CF value very close or equal to the global minimum. The results of CF minimization and comparison with the results from other sources are provided. The direct CF optimization results (set of optimal phases) are not well suited for practical implementation. The influence of phase accuracy on the CF is discussed, and an algorithm for the recalculation of initial phases to the rougher set is described. It is shown that previously obtained optimization results (minimal CF) can be highly preserved, even in the case of rough phase resolutions. The CF of the multisine also depends on the frequency distribution and amplitudes of its components. The CF of multisines with several frequency distributions are compared.

20 April 2019 in Sensors
Verified
Journal Article
Open access
PDF file
JOJaan Ojarand
Jaan Ojarand
MMMart Min
Mart Min
AKAnts Koel
Ants Koel
Impedance spectroscopy is a common approach in assessing passive electrical properties of biological matter. However, several problems appear in microfluidic devices in connection with the requirement for high sensitivity of signal acquisition from small volume sensors. The developed compact and inexpensive analyzer provides impedance spectroscopy measurement from three sensors, both connected in direct and differential modes. Measurement deficiencies are reduced with a novel design of sensors, measurement method, optimized electronics, signal processing, and mechanical design of the analyzer. Proposed solutions are targeted to the creation of reliable point-of-care (POC) diagnostic and monitoring appliances, including lab-on-a-chip type devices in the next steps of development. The test results show the good working ability of the developed analyzer; however, also limitations and problems that require attention and further improvement are appointed.

25 April 2017 in Elektronika ir Elektrotechnika
Verified
Journal Article
Open access
PDF file
JOJaan Ojarand
Jaan Ojarand
MMMart Min
Mart Min
Recent Advances in Crest Factor Minimization of Multisine

1 January 2018 in Journal of Electrical Bioimpedance
Verified
Journal Article
Open access
JOJaan Ojarand
Jaan Ojarand
MMMart Min
Mart Min
Different excitation signals are applicable in the wideband impedance spectroscopy in general. However, in electrical bioimpedance (EBI) measurements, there are limitations that set specific demands on the properties of the excitation signals. This paper compares the efficiency of different excitation signals in a graspable presentation and gives recommendations for their use. More exactly, the paper deals with finding the efficient excitation waveforms for the fast spectroscopy of electrical bioimpedance. Nevertheless, the described solutions could be useful also in other implementations of impedance spectroscopy intended for frequency domain characterization of different objects.

1 January 2011
Verified
Book Chapter
Closed access
PDF file
PAP. Annus
P. Annus
MMM. Min
M. Min
JOJaan Ojarand
Jaan Ojarand
TPT. Paavle
T. Paavle
RLR. Land
R. Land
TPT. Parve
T. Parve

1 August 2012
Verified
Conference Paper
Closed access
MMM. Min
M. Min
JOJaan Ojarand
Jaan Ojarand
OMOlev Märtens
Olev Märtens
TPT. Paavle
T. Paavle
RLR. Land
R. Land
TPT. Parve
T. Parve
Using of binary waveforms in the fast impedance spectroscopy of biological objects is discussed in the paper. There is shown that the energy of binary waveforms can be concentrated onto selected separate frequencies. We can optimize the binary excitation waveform depending on the shape of frequency response of the impedance under study to maximize the levels of signal components with certain selected frequencies. As a result, we are able to receive maximal amount of information about the properties and behavior of the impedance to be studied. We have designed and prototyped the impedance spectroscopy device operating in the frequency range from 100 mHz to 500 kHz to cover α- and β-regions of the bio-impedance spectrum of time-varying subjects as, for example, fast moving cells in micro-fluidic devices, beating heart and breathing lungs or the whole cardiovascular system.