Hui Huang

Dr. Hui Huang

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 March 2021 in Sensors
Verified
Journal Article
Open access
PDF file
HSHong Song
Hong Song
SMSyed Raza Mehdi
Syed Raza Mehdi
YZYangfan Zhang
Yangfan Zhang
YSYichun Shentu
Yichun Shentu
QWQixin Wan
Qixin Wan
HHHui Huang
Hui Huang
Among aquatic biota, corals provide shelter with sufficient nutrition to a wide variety of underwater life. However, a severe decline in the coral resources can be noted in the last decades due to global environmental changes causing marine pollution. Hence, it is of paramount importance to develop and deploy swift coral monitoring system to alleviate the destruction of corals. Performing semantic segmentation on underwater images is one of the most efficient methods for automatic investigation of corals. Firstly, to design a coral investigation system, RGB and spectral images of various types of corals in natural and artificial aquatic sites are collected. Based on single-channel images, a convolutional neural network (CNN) model, named DeeperLabC, is employed for the semantic segmentation of corals, which is a concise and modified deeperlab model with encoder-decoder architecture. Using ResNet34 as a skeleton network, the proposed model extracts coral features in the images and performs semantic segmentation. DeeperLabC achieved state-of-the-art coral segmentation with an overall mean intersection over union (IoU) value of 93.90%, and maximum F1-score of 97.10% which surpassed other existing benchmark neural networks for semantic segmentation. The class activation map (CAM) module also proved the excellent performance of the DeeperLabC model in binary classification among coral and non-coral bodies.

Verified
Journal Article
Open access
PDF file
HSHong Song
Hong Song
SMSyed Raza Mehdi
Syed Raza Mehdi
CWChaopeng Wu
Chaopeng Wu
ZLZixin Li
Zixin Li
HGHai Gong
Hai Gong
HHHui Huang
Hui Huang
In the past decade, underwater spectral imaging (USI) has shown great potential in underwater exploration for its high spectral and spatial resolution. This proposal presents a stare-type USI system combined with the liquid crystal tunable filter (LCTF) spectral splitting device. Considering the working features of LCTF and the theoretical model of USI, the core structure containing “imaging lens-LCTF-imaging sensor” is designed and developed. The system is compact, and the optical geometry is constructed minimally. The spectral calibration test analysis proved that the spectral response range of the system covers a full band of 400 nm to 700 nm with the highest spectral resolution between 6.7 nm and 18.5 nm. The experiments show that the system can quickly collect high-quality spectral image data by switching between different spectral bands arbitrarily. The designed prototype provides a feasible and reliable spectral imaging solution for in situ underwater targets observation with high spectrum collecting efficiency.

25 January 2022 in Remote Sensing
Verified
Journal Article
Open access
PDF file
SMSyed Raza Mehdi
Syed Raza Mehdi
KRKazim Raza
Kazim Raza
HHHui Huang
Hui Huang
Rizwan Ali NaqviRizwan Ali Naqvi
Rizwan Ali Naqvi
Amjad Ali AmjadAmjad Ali Amjad
Amjad Ali Amjad
HSHong Song
Hong Song
Vital transportation of hazardous and noxious substances (HNSs) by sea occasionally suffers spill incidents causing perilous mutilations to off-shore and on-shore ecology. Consequently, it is essential to monitor the spilled HNSs rapidly and mitigate the damages in time. Focusing on on-site and early processing, this paper explores the potential of deep learning and single-spectrum ultraviolet imaging (UV) for detecting HNSs spills. Images of three floating HNSs, including benzene, xylene, and palm oil, captured in different natural and artificial aquatic sites were collected. The image dataset involved UV (at 365 nm) and RGB images for training and comparative analysis of the detection system. The You Only Look Once (YOLOv3) deep learning model is modified to balance the higher accuracy and swift detection. With the MobileNetv2 backbone architecture and generalized intersection over union (GIoU) loss function, the model achieved mean IoU values of 86.57% for UV and 82.43% for RGB images. The model yielded a mean average precision (mAP) of 86.89% and 72.40% for UV and RGB images, respectively. The average speed of 57 frames per second (fps) and average detection time of 0.0119 s per image validated the swift performance of the proposed model. The modified deep learning model combined with UV imaging is considered computationally cost-effective resulting in precise detection accuracy and significantly faster detection speed.

31 October 2021 in Animals
Verified
Journal Article
Open access
PDF file
FTFabrice Arnaud TEGOMO
Fabrice Arnaud TEGOMO
ZZZhiwen Zhong
Zhiwen Zhong
ANAchille Pandong Njomoue
Achille Pandong Njomoue
SOSamuel Ukpong Okon
Samuel Ukpong Okon
SUSami Ullah
Sami Ullah
QSQingjun Shao
Qingjun Shao
Acidification (OA), a global threat to the world’s oceans, is projected to significantly grow if CO2 continues to be emitted into the atmosphere at high levels. This will result in a slight decrease in pH. Since the latter is a logarithmic scale of acidity, the higher acidic seawater is expected to have a tremendous impact on marine living resources in the long-term. An 8-week laboratory experiment was designed to assess the impact of the projected pH in 2100 and beyond on fish survival, health, growth, and fish meat quality. Two projected scenarios were simulated with the control treatment, in triplicates. The control treatment had a pH of 8.10, corresponding to a pCO2 of 321.37 ± 11.48 µatm. The two projected scenarios, named Predict_A and Predict_B, had pH values of 7.80-pCO2 = 749.12 ± 27.03 and 7.40-pCO2 = 321.37 ± 11.48 µatm, respectively. The experiment was preceded by 2 weeks of acclimation. After the acclimation, 20 juvenile black sea breams (Acanthopagrus schlegelii) of 2.72 ± 0.01 g were used per tank. This species has been selected mainly due to its very high resistance to diseases and environmental changes, assuming that a weaker fish resistance will also be susceptibly affected. In all tanks, the fish were fed with the same commercial diet. The seawater’s physicochemical parameters were measured daily. Fish samples were subjected to physiological, histological, and biochemical analyses. Fish growth, feeding efficiency, protein efficiency ratio, and crude protein content were significantly decreased with a lower pH. Scanning electron microscopy revealed multiple atrophies of microvilli throughout the small intestine’s brush border in samples from Predict_A and Predict_B. This significantly reduced nutrient absorption, resulting in significantly lower feed efficiency, lower fish growth, and lower meat quality. As a result of an elevated pCO2 in seawater, the fish eat more than normal but grow less than normal. Liver observation showed blood congestion, hemorrhage, necrosis, vacuolation of hepatocytes, and an increased number of Kupffer cells, which characterize liver damage. Transmission electron microscopy revealed an elongated and angular shape of the mitochondrion in the liver cell, with an abundance of peroxisomes, symptomatic of metabolic acidosis.

13 March 2023 in Frontiers in Marine Science
Verified
Journal Article
Open access
HSHong Song
Hong Song
SMSyed Raza Mehdi
Syed Raza Mehdi
ZLZixin Li
Zixin Li
MWMengjie Wang
Mengjie Wang
CWChaopeng Wu
Chaopeng Wu
HHHui Huang
Hui Huang
Spectral reflectance detection of the targeted object is considered a vital inherent optical property for its potential to provide abundant spectral information, which is crucial in underwater spectral imaging. However, the coarse condition of the underwater environment due to turbidity causes extreme distortions in spectral reflectance detection due to the high absorption and scattering of light. To cope with the effects of light degradation on underwater spectral reflectance detection accuracy, the rate of the impacts of turbidity on spectral reflectance should be examined thoroughly. Therefore, we utilize a stare-type underwater spectral imaging system based on a liquid crystal tunable filter (LCTF) to study the effects of turbidity in underwater spectral imaging of various colored bodies. To examine the accuracy of underwater spectral reflectance detection based on escalating turbidity, the paper models the rate of increase in scattering intensity of the water body. Results show that, based on the non-linear increase in the pixel response of the black and white board, the rapid upsurge in scattering intensity occurs between 400nm to 500nm at different turbidity levels. Additionally, the spectral reconstruction of color bodies relative to the black and white board shows the maximum absolute deviation of 5.3% in spectral reflectance detection accuracy under varying turbidity. While employing underwater spectral imaging, the above findings of optimal band selection can find significant applications to improve the quality of underwater object detection.

29 September 2017 in Applied Optics
Verified
Journal Article
Closed access
PDF file
HWHangzhou Wang
Hangzhou Wang
LNLiwen Nan
Liwen Nan
HHHui Huang
Hui Huang
PYPing Yang
Ping Yang
HSHong Song
Hong Song
YCYing Chen
Ying Chen
Adaptive measurement is a major concern when using miniature spectrometers in extreme environments, especially when the ambient temperatures and incident light intensities vary greatly. In this study, parameters, including the signal output and the relevant noise and signal-to-noise ratio (SNR) of a fiber optic spectrometry system composed of a photodiode array miniature spectrometer and external driver electronics were examined at multiple integration times from −50°C to 30°C, well below the specified operating temperature of this spectrometer. The relationships between those parameters and incident light level were also examined, at a single temperature of 0°C. Based on these examinations, temperature-induced biases in the linear operating range of the spectrometer were identified. Signal output and the relevant noise and SNR in response to different integration times, temperatures, and incident light levels were assessed separately. These assessments were then used to develop an adaptive measurement method for estimating the incident light level and setting up an optimal integration time for this spectrometer, while autonomously adapting the variation in the ambient temperature and incident light level simultaneously. This approach provides a general framework for developing an adaptive measurement algorithm for miniature spectrometers, which face tremendous variations in ambient temperature and incident light level.