This paper presents the implementation of a single-phase solid-state transformer (SST) for the interface between a 13.2 kV medium voltage alternative current (MVAC) network and a 750 V bipolar DC distribution. The SST has ten cascaded subunits in consideration of the device rating and modulation index (MI). Each subunit consists of an AC/DC stage and a DC/DC stage with a high frequency isolated transformer (HFIT). The AC/DC stage consists of cascaded H-bridges (CHBs) to cope with the MVAC. The DC/DC stage employs a triple active bridge (TAB) converter for bipolar DC distribution. Topology analysis and controller design for this specific structure are discussed. In addition, the insulation of HFIT used in DC/DC converters is also discussed. A simple balancing controller at the AC/DC stage and a current sharing controller at the DC/DC stage are used to prevent DC-link voltage unbalance caused by the cascaded structure. The discussions are validated using a 150 kW single-phase 21-level SST prototype at the laboratory level.
This paper proposes a DC-bus signaling (DBS) method for autonomous power management in a DC microgrid, used to improve its reliability. Centralized power management systems require communication between the power sources and loads. However, the DBS method operates based on the common DC-bus voltage and does not require communication. Based on the DC-bus voltage band, the DC-bus voltage can be used to inform the status of the DC-bus in various scenarios. The DC microgrid operates independently to maintain the system stably in the DC-bus voltage band. The DC microgrid can be divided into a grid-connected mode and an islanding mode. This paper proposes a control strategy based on power management of various independent components in islanding mode. In addition, the autonomous control method for switching the converter’s operation between grid-connected mode and islanding mode is proposed. A DC microgrid test bed consisting of a grid-connected AC/DC converter, a bidirectional DC/DC converter, a renewable energy simulator, DC home appliances and a DC-bus protector is used to test the proposed control strategy. The proposed autonomous control strategy is experimentally verified using the DC microgrid test bed.
Renewable energy needs are steadily on the rise. Bidirectional DC/DC converters are essential in charging and discharging various storage batteries, such as PV/ESS (photovoltaic/energy storage system). A dual active bridge (DAB) converter, in particular, transfers power in both directions by phase shift using a soiled state transformer (SST). To reduce switching inrush current in batteries under high voltages, a soft start-up is demonstrated during the initial switching operation. When a supercapacitor (SC) is used as a battery, the reverse power caused by the inrush current appears under high voltage at the DC-link side. This causes serious electrical damage to the PV/ESS’ boost converter and inverter. To suppress peak overshoot voltage and stabilize soft start-up transients, we propose a three-step soft start-up controller and algorithm for bidirectional DAB converter implementation at virtual ESS and UPS. The step-by-step control strategy by OLDC (open loop duty control), OLPSC (open loop phase shift control), and OLFC (open loop frequency control) provides a stable soft start-up operation. In the initial stage of the OLDC, the duty ratio is gradually increased by the PWM (Pulse width modulation) signal. In the middle stage, a phase difference is seen as per the voltage of the SC. The OLPSC is performed to reduce the phase difference. In the final stage, the OLFC is performed to smoothly control the small phase difference. The overshoot or inrush current is drastically suppressed toward the DC-link and SC module. Consequently, we demonstrate a proposed controller and algorithm with prototype 5 kW DAB converter.